_ _. _
' 53/3 m w w w w?Ela 4
00LKETED USNRC UNITED STATES OF AMERICA JAN 11 P6 20 NUCLEAR REGULATORY COMMISSION before the 0Frict 0; srmy tw 00CXEIma a "iEi,vmt, 1
ATOMIC SAFETY AND LICENSING BOARD BRANCH
)
In the Matter of
)
)
PUBLIC SERVICE COMPANY
)
Docket Nos. 50-443-OL OF NEW HAMPSHIRE, ET AL.
)
50-444-OL
)
(Seabrook Station, Units 1
)
(Offsite Emergency and 2)
)
Planning Issues)
)
APPLICANTS' REBUTTAL TESTIMONY NO. 1 (Rebuttal to Dr. Avishai Ceder)
Witness:
Edward Lieberman This testimony addresses a few miscellaneous items in the direct testimony of Dr. Ceder.
Professor Ceder objectc to the use of the "BPR Formula" for estimating travel time as a function of volume.
However, the "BPR Formula" has a long history and extettsive use among practicing transportation planners.
The "a" and "b" parameters cited by Professor Ceder on page 21 of his testimony are used to calibrate the BPR formula shown on page B-1 of Volume 6.
This formula is employed as the objective function of the equilibrium traffic assignment in IDYNEV and is also used extensively elsewhere.
1 88011300 4 880111' U
FDR ADOCK 05000443 T
4 1
The largest recent calibration activity'that I know of, took place in Winnipeg and involved some 2836 unidirectional links.
The~ links were organized according to speed limit and other
)
l attributes.
The range of calibrated values-for "a" was 0.62 to
-1.15, and for "b" was 4.4 to 6.8.
The representative values used j
in I-DYNEV were, respectively, 0.8 and 5.0.
Ref.: Validation and Apr2. cation of an Equilibrium-Based Two-Mode Urban Transportation Planning Method (EMME) by M.
Florian, et al., TRR 728.
We have conducted a sensitivity study of the Region 1,
-Scenario 1 Case to assess the elasticity of ETE to changes in the values of "a" and "b".
We used the traditional values of 0.15 and 4.0 for "a" and "b",
respectively.
The results of this test are as follows:
a b
EII Comments 0.8 5.0 7:05 Planning Basis 0.15 4.0 7:10 Sensitivity Test As indicated, the ETE is insensitive to the values assigned-to "a" and "b".
Professor Ceder observes that what he refers to as Article 2 assumes that "all links have the same values of capacity, length, and free-flow travel times".
This is not a relevant citation since it does not apply to I-DYNEV, but to an illustrative example used to demonstrate the features of a new model named TRAD which was not used in this study.
2
3-t 00CMETED CERTIFICATE OF SERVICE USNBC I,
Kathryn A.
Selleck, one of the. attorneys for the Applicants herein, hereby certify that on January 6,189amN 11 P6 :20 made service of the within document by depositing copies thereof with Federal Express, prepaid, for. delivery t (or,. Y ggy where indicated, by depositing in the United States gj hylCf.
first class posta.ge paid, addressed to):
BRANCH Administrative Judge Ivan W. Smith Robert Carrigg, Chairman Chairman, Atomic Safety and Board of Selectmen Licensing Board Panel Town Office U.S.
Nuclear Regulatory Atlantic Avenue Commission North Hampton, NH 03862 East West Towers Building 4350 East West Highway Bethesda, MD 20814 Judge Gustave A. Linenberger Diane Curran, Esquire Atomic Safety and Licensing
.Andrea C.
Ferster, Esquire Board Panel Harmon & Weiss U.S.
Nuclear Regulatory Suite 430 Commission 2001 S Street, N.W.
East West Towers Building Washington, DC 20009 4350 East West Highway Bethesda, MD 20814 Dr. Jerry Harbour Stephen E. Merrill Atomic Safety and Licensing Attorney General Board Panel George Dana Bisbee U.S. Nuclear Regulatory-Assistant Attorney General Commission Office of the Attorney General East West Towers Building 25 Capitol Street 4350 East West Highway Concord, NH 03301-6397 Bethesda, MD 20814 Atomic Safety and Licensing Sherwin E. Turk, Esquire Board Panel Office of General Counsel U.S.
Nuclear Regulatory U.S.
Nuclear Regulatory Commission Commission East West Towers Building 15th Floor 4350 East West Highway 11555 Rockville Pike Bethesda, MD 20814 Rockville, MD 20852
- Atomic Safety and Licensing Robert A.
Backus, Esquire Appeal Board Panel 116 Lowell Street U.S.
Nuclear Regulatory P.
O.
Box 516 Commission Manchester, NH 03105 Washington, DC 20555 l
I Philip Ahrens, Esquire Mr.
J.
P.
Nadeau Assistant Attorney General Selectmen's Office Department of the Attorney 10 Central Road l
General Rye, NH 03870 l
Augusta, ME 04333 Paul McEachern, Esquire Carol S.
Sneider, Esquire Matthew T.
Brock, Esquire Assistant Attorney General I
Shaines & McEachern Department of the Attorney 25 Maplewood Avenue General P.O.
Box 360 One Ashburton Place, 19th Fir.
Portsmouth, NH 03801 Boston, MA 02108 Mrs. Sandra Gavutis Mr. Calvin A.
Canney Chairman, Board of Selectmen City Manager RFD 1 - Box 1154 City Hall Route 107 126 Daniel Street Kensington, NH 03827 Portsmouth, NH 03801
- Senator Gordon J.
Humphrey Mr. Angie Machiros U.S.
Senate Chairman of the Board of Washington, DC 20510 Selectmen (Attn:
Tom Burack)
Town of Newbury Newbury, MA 01950
- Senator Gordon J.
Humphrey Mr. Peter J.
Matthews One Eagle Square, Suite 507 Mayor Concord, NH 03301 City Hall (Attn:
Herb Boynton)
Newburyport, MA 01950 Mr. Thomas F.
Powers, III Mr. William 3.
Lord Town Manager Board of Selectmen Town of Exeter Town Hall - Friend Street 10 Front Street Amesbury, MA 01913 Exeter, NH 03833 H.
Joseph Flynn, Esquire Brentwood Board of Selectmen Office of General Counsel RFD Dalton Road Federal Emergency Management Brentwood, NH 03833 Agency 500 C Street, S.W.
Washington, DC 20472 Gary W.
Holmes, Esquire Richard A.
Hampe, Esquire Holmes & Ells Hampe and McNicholas 47 Winnacunnet Road 35 Pleasant Street Hampton, NH 03841 Concord, NH 03301 f I
l l
e
\\
Mr. Ed Thomas Judith H. Mizner, Esquire FEMA, Region I Silverglate, Gertner, Baker, 442 John W. McCormack Post Fine, Good & Mizner Office and Court House 88 Broad Street Post Office Square Boston, MA 02110 Boston, MA 02109 Charles P. Graham, Esquire McKay, Murphy and Graham 100 Main Street Amesbury, MA 01913
./.
Am
/ <
K6tf[i yn ' A'.
S W1eck
(*= Ordinary U.S. First Class Mail) i ____-__--_---
i