ML20234F562

From kanterella
Jump to navigation Jump to search
Partially Withheld Insp Rept 50-416/87-38 on 871130-1201 (Ref 10CFR2.790(d) & 73.21).Violations Noted.Major Areas Inspected:Circumstances of Licensee Reported Security Event Re Delayed Response to Vital Area Intrusion Alarm
ML20234F562
Person / Time
Site: Grand Gulf 
Issue date: 12/22/1987
From: Mcguire D, Tillman A
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
To:
Shared Package
ML20234F561 List:
References
50-416-87-38, NUDOCS 8801110525
Download: ML20234F562 (1)


See also: IR 05000416/1987038

Text

L

-

4 AFFm @pLlNFORMATIONl

[, ,,,'%,^

NUCLEAR REGU1.ATORY COMMISSION

"

-

  1. N'

REGION 11

h

.I

d

101 MARIETTA STREET, N.W.

  • i

'f

ATLANTA, GEORGI A 30323

,

    • .'....l

DEC38 1997

Report No. 50-416/87-38

Licensee: System Energy Resources, Inc.

Jackson, MS 39205

Docket No. 50-416

License No. NPF 29

Facility Name:

Grand Gulf

Inspection Conducted: November 30 - Dece:aber 1,1987

Inspector. N

wh

/2/Ja/F7

.

g/3.Till7tn,

ysicalSeegrityInspector

Date Signed

Approved

/

[

Plf/

/ M

f f- [

. fife,\\ Chief, Physic'El Security-Section

Date' Signed

.

Nuclear Materials Safety and Safeguards Branch

Dicisir.n of Radietion Safety and Safeguards

SUMMARY

Scope:

This special reactive ~ inspection was conducted to review the

'

circumstances of a ifcensee reported security event relating to a delayed

response to an vital crea intrusion alarm.

Results:

Review and inspection confirmed the occurrence of two licensee

identified violations-of procedural requirements.

1.

Delayed response and implementation of compensatory measures for an

i

improperly secureo vital area door.

2.

Delayed submission of a security event report to the NRC beyond the

)

required one hour time period.

In accordance with the provisions of the NRC Enforcement Policy

(10 CFR Part 2, Appendix C, Section V-A) a notice of violation was not issued

1

for these licensee-fdentified violations.

O

16

PDR

RMCLOSURE CONTA

UPON SEPARA

PAGE 18 DECONTRO

SAFEGUARDS INFORMATION

.

_

- - - -

-- ---

-

-