._,

4 j

l June 29, 1987 i

l NRC/THI-87-050 j

l MEMORANDUM FOR:

Dennis M. Crutchfield, Director Division of Reactor Projects - III,lV,V & Special Projects Frank Schroeder, Jr., Assistant Director

{

l Region IV Reactors end Speciel Projects j

l l

i l

FROM:

William D. Travers, Director I

TMI-2 Cleanup Project Directorate i

SunJECT:

NRC TMI-2 CLEANUP PROJECT DIRECTORATE WEEKLY STATUS j

REPORT FOR JUNE 22 - 28, 1987 1

1.

DEFUELING I

Pick and place defueling of partial length fuel assemblies and fuel pins continued.

P6rtial fuel assemblies E-4, D-4, C-4, B-4, L-12, 4

C-12 and D-11 were broken free from the lower grid. All but D-11 have been leaded into defueling canisters. A total of 33 fuel assemblies out of 177 in the core have now been broken free from the icwer grid.

Tnree canisters were filled and three partially filled.

Six canisters, including three filled in the previous week, were transferred to the spent fuel pool.

2.

ENVIRONMENTAL MONITORING l

1 US Environmental Protection Agency (EPA) sample analysis results show that THI site liquid effluents are in accordance with regulatory limits, NRC requirements, and the City of Lancaster Agreement, TMI water effluents from the station (Units 1 and 2) discharge are analyzed by EPA.

G m a spectrum analyses of the seven daily composited samples for June 6 - 13, 1987 indicated no THI-2 related radioactivity.

EPA's garsa spectrum analysis of the NRC's Tiil outdoor air sample for June 6 - 13, 1987 showed no reactor related radioactivity.

The water works for the City of Lancaster composited seven daily samples from June 6 - 13, 1987.

EPA's ganaia spectrum analysis of I

the composite sample showed no reactor related radioactivity.

3.

NRC EVALUATIONS IN PROGRESS Technical Specification Change Requests 52, 53 and 56.

Recovery Operations Plan Change Requests 38 and 41.

Solid Waste Facility Technical Evaluation Report.

Heavy Load Safety Evaluation Report, Revision 3.

cmcub sua== >

8707060511 870629 PDR ADOCK 05000320

===>

R PDR

.7

.i un e m e u.....

m. mm m

--m.

n hrerenen a n mramrm emu,

j

^

'V

. Dennis & Crutchfield 2

June 29, 1987 Frank Schroeder, Jr.

j NRC/TMI-87-050 1

)

2 Z.'.2~~h-QrAceised Water Disposition Proposal.

I

$2dty-Evaluation Report for Use of Plasma Arc Cutting Torch.

Pressurizer Defueling Safety Evaluation Report!

Safety Evaluation Report for Defueling of the ' Core Support Assembly.

q Environa, ental Evaluation of the Post-Defueling Monitored Storage Proposal.

Canister Handling and Preparation for Shipment Safety

-1 Evaluation Report, Revision 4.

I Defueling Water Cleanup System Technical Evaluation Report Ant.ual Update.

Defueling Canister Technical Evaluation Report Annual Update.

i EPICOR II System Description Annual Opdate.

4. -

PUnl.IC MEETING The Advisory Panel for the Decontamination of Three Mile ' Island Unit 2 l

has tentatively set August 12, 1987 as their next public meecing in Harrisburg, PA. Meeting specifics will be provided at a later date.

l l

ORIG lHAL &lN We wimam D. Trowes William D. Travers Director TNI-2 Cleanup Project Directorate l

l WCE )

SURNAMEk

^">

l.........

NRC FORM 318 (10 80) NRCM 0240 OFFICIR RECORD COPY

^*

Dennis M. Crutchfield 3

June 29, 1987 Frank Schroeder, Jr.

NRC/TNI-87-050 INTERML DISTRIBUTION I

HiiTkTATE NRC PDR LOCAL PDR EDO OGC EPA DDE R1 Regional AJa;inistrator i

RI Division Directors Public Affairs, RI State Liaison, RI TMI HQ r/f TriI SITE r/f TMI-2 Project Section File TMI-1 Resident Of fice (5)

TMI Cleanup Project Directorate (14) l l

1 l

l l

l l

I I

i 1

l l

I l

l l

l 1

orrice> TMICPD TMICPD TMICPg TM CPD SUF(NAMt > LTho,n,u,s,: je,s,, T,M,o,s,1,,,

JT,horhas',,,,,,, wit,ve s,,,,,

s u)@7......6Mt.87.....

. sat /.87......

o ^" >

6/4.87......

/

___