ML20234C413

From kanterella
Jump to navigation Jump to search
Forwards Radioactive Effluent Rept for Jan-June 1987.Oct 1986 Value Causing High Value for Fourth Quarter 1986 Reanalyzed & Found to Be Lower.Particulate Values for 1984, 1985 & 1986 Reported Low Due to Vacuum Correction Errors
ML20234C413
Person / Time
Site: Quad Cities  
Issue date: 08/12/1987
From: Bax R
COMMONWEALTH EDISON CO.
To: Bradley Davis
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
Shared Package
ML20234C416 List:
References
RLB-87-217, NUDOCS 8709210280
Download: ML20234C413 (1)


Text

-.

nwa O 22710 206 Avenue North pS

.Vi -

Commonw:alth Edison P7t10RITY ROUT 1pG Quad Cities Nuclear Power Station f P5t 5 ^Ab

)u 3

~

Cordova, Illinois 61242 MP Telephone 309/654-2241 7

'O ksfAL RLB-87-217 MA R

FILE g i

i August 12, 1987 Mr. Bert Davis Acting Regional Administrator Directorate of Inspection and Enforcement Region III

-j U.S Nuclear Regulatory Commission 799 Roosevelt Road Glen Ellyn, Illinois 60137

SUBJECT:

Quad Cities Station Operating Report, NRC Dockets l

50-254 and 50-265 l

Dear Mr. Davis:

l Enclosed is the Radioactive Effluent. Report for January through June, 1987 for Quad Cities Nuclear Power Station.

The Fourth Quarter 1986 Gross Alpha Radioactivity Particulate Value discussed as being questionable in the last report has been-investigated. The value for October 1986 which caused the high value for the quarter was re-analyzed and found to be lower. The corrected value for the Fourth Quarter 1986 is 6.83E-06 C1.

As discussed in DVR 4-1-87-034 the Particulate Values for 1984, 1985'and 1986 were reported low due to vacuum correction errors.

The values for the reactor-vent were increased by fif ty percent and the main chimney values were increased by ten percent.

Copies of corrections are attached.

^

One copy of each report is provided for your use and 'eight copies are being distributed per the rules and regulations out? aed in the November 1986 Federal Register.

Sincerely, R.A.Pd o

R. L. Bax %

p Station Manager 7 QD RLB/RW/kmb Enclosure 8709210280 870812 L?

PDR ADOCK 05000254 R

PDRc~

SEP 1 5 1987

]