Responds to NRC Ltr Re Violations Noted in Insp Rept 50-424/87-30.Corrective Actions:Auxiliary Bldg Surveyed & Posted in Accordance W/Procedure 00930-C & Personnel Counseled on Proper Survey & Documentation Techniques
ML20234B805
Person / Time
Site: Vogtle 
Issue date: 06/26/1987
From: Gucwa L
GEORGIA POWER CO.
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
SL-2727, NUDOCS 8707060214
Download: ML20234B805 (6)


Text

'

Georgia Fbwer Company.

333 Piedmont Avenue Atlanta, Georgia 30308 '

Telephone 404 526 6526 Malling Addrecs Fbst Office Box 4545 A-flanta, Georgia 30302 h

Georgia Power L T. Gucwe Ine !.vainern eksinc system Manager Nuclear Safety and Licensing SL-2727 0370m X7GJ17-V120 June 26, 1987 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.

20555 PLANT V0GTLE - UNIT 1 NRC DOCKET 50-424 OPERATING LICENSE NPF-68 RESPONSE TO NRC INSPECTION REPORT Gentlemen:

Pursuant to the provisions of 10 CFR 2.201, Georgia Power Company.

(GPC) submits the enclosed information in response to NRC Inspection Report 50-424/87-30, which concerns the inspection conducted by Mr. F. N.

Wright of NRC Region II ori April 28 - May 1,

1987.

Two apparent violations were cited in the Notice of. Violation included in the' subject inspection report.

A copy of this response is ' being provided to the NRC Region II office.

In each enclosure, transcription of the NRC violation precedes GPC's response.

Should you have any questions in this regard, please contact this office at any time.

Sincerely,

/GQm L. T. Gucwa JAE/JH/lm l

Enclosures:

l 1.

Violation 87-30-01 and GPC Response i

2.

Violation 87-30-02 and GPC Response c:

(see next page) 7060214 g70626 g

ADOCK 05000424 i

PDR

i k

Georgia Power n l

U. S. Nuclear Regulatory Commission j

June 26, 1987 Page Two I

c: G10rqia Powerl opp 3ny n

Mr. R. E. Conway 1

Mr. J. P. O'Reilly j

Mr. G. Bockhold, Jr.

J Mr. J. F. D'Amico l

Mr. C. H. Hayes I

GO-NORMS

]

i Sng 1hern Company Services I

Mr. R. A. Thomas Mr. J. A. Bailey l

S. haw Pittman. Potts & Trowbridge l

Mr. B. H. Churchill, Attorney-at-Law I

l l

Irontman. Sanders. Lockerman & Ashmore l

Mr. A. H. Domby, Attorney-at-Law U. S. NRClear. Regulatory Commission Dr. J. N. Grace, Regional Administrator Ms. M. A. Miller, Licensing Project Manager, NRR (2 copies)

Mr. J. F. Rogge, Senior Resident Inspector-0perations, Vogtle Gepraigns Against Nuclear Energy i

Mr. D. Feig Ms. C. Stangler 0370m i

1 4g I

Georgia Pcnver mL.

]

I ENCLOSURE 1 PLANT V0GTLE - UNIT 1 NRC DOCKET 50-424 OPERATING LICENSE NPF-68 i

NRC NOTICE OF VIOLATION 87-30-01 AND GPC RESPONSE VIOLATION 50-424/87-30-01:

)

"10 CFR 20.201(b) states that each. licensee shall make such surveys as may be.necessary for the licensee to comply with the regulations in Part 20 and are reasonable under the circumstances to evaluate the extent of radiation hazards that may be present.

10 CFR 20.203(b) requires a licensee to post each radiation area with a conspicuous sign or signs bearing the radiation caution symbol and the words:

Caution, Radiation Area.

A radiation area is defined, in 10 CFR 20.202(b)(2), as any area, accessible to personnel, in which there exists radiation, originating in whole or in part within licensed material, at such levels that a major portion of the body could receive in any one hour a dose in excess of 5 millirems, or in any five consecutive days a dose in excess of 100 millirems.

Contrary to the above, during April 1987, the licensee did not make such surveys as were necessary to identify and post a radiation area in the Equipment Storage Room (RA-27).

An individual, if continuously present there, could have received a dose of six millirem in any one hour.

I This is a Severity Level IV violation (Supplement IV)."

Resoonse to Violation 50-424/87-30-011 Admissiqn or denial of alleged violation 1 The event occurred as stated in the inspection report.

0370m El-1 6/26/87 SL-2727 mn

Georgia Power 1 ENCLOSURE 1 (Continued)

NRC NOTICE OF VIOL,' TION 87-30-01 AND GPC RESPONSE Re son for the violation:

When the violation was identified on April 28, 1987, the plant was escalating in power from 23% to 72% reactor power at approximately 8%

power increase per hour.

The plant was initially posted in accordance with the predicted dose rates contained in FSAR Section 12.3.

Area iisse rates were then verified by surveys during low power operation and the postings were modified appropriately to reflect the surveys performed.

The failure to survey the area of concern is jointly attributed to inadequate work planning and coordination.

Corrective steos which have been taken and the results achieved:

Room RA-27 of the Auxiliary Building was immediately surveyed and posted in accordance with Procedure 00930-C,

" Radiation and Contamination 4

Control".

A review was conducted to determine if any other areas with dose rates differing from those specified in FSAR Section 12.3 should have been surveyed.

The appropriate areas were surveyed and posted.

HP personnel have been re-trained in 10 CFR 20 and HP procedural requirements with regard to the frequency of conducting surveys.

Additional HP technician positions have been approved and GPC is actively pursuing filling these positions with qualified and experienced personnel to support survey activities.

l Corrective steos which will be taign to avoid further violations:

Procedure 00930-C is being revised to increase the emphasis on surveying and posting of areas where the potential exists for radiation to exceed 10 CFR 20.203(b) requirements.

This revision is expected to be complete by July 24, 1987.

Date when full como11ance will be achieved:

The immediate surveying and posting of the subject area has placed us in compliance.

0370m El-2 6/26/87 SL-2727 700776

o

)

l i

k Georgia Power h i

ENCLOSURE 2 PLANT V0GTLE - UNIT 1 NRC DOCKET 50-424 OPERATING LICENSE NPF-68 NRC NOTICE OF VIOLATION 87-30-02 AND GPC RESPONSE VIOLATION 50-424/87-30-02:

"10 CFR 20.401(b) requires a licensee to maintain records showing the results of surveys required by 10 CFR 20.201(b).

10 CFR 20.201(b) requires a licensee to make such surveys as may be necessary to comply with the regulations of 10 CFR 20.

Contrary to the above, the licensee did not maintain records of radiation 2

surveys required by 10 CFR 20.201(b) that were made April 28, 1987, in I

the Equipment Storage Room (RA-27).

I This is a Severity Level V violation (Supplement IV)."

Resoonse to Violation 50-424/87-30-02:

Admission or denial of alleged violation:

The event occurred as stated in the inspection report.

Reason for the violation:

HP personnel failed to follow Procedure 00930-C,

" Radiation and Contamination Control", with regards to documenting required radiation surveys.

Corrective steos which have been taken and the results achieved:

The subsequent surveys of Room RA-27 were documented in accordance with Procedure 00930-C.

HP personnel have been made cognizant of this violation during shift briefings and have been counseled on proper survey i

techniques and documentation requirements.

Corrective steos which will be taken to avoid further violations:

The above steps should prevent recurrence of this violation.

0370m E2-1 6/26/87 SL-2727 70077$

Geoigia Power b ENCLOSURE 2 (Continued)

NRC NOTICE OF VIOLATION 87-30-02 AND GPC RESPONSE Date When full comoliance will be achieved:

Subsequent surveys of the subject area were conducted and documented to bring us into current compliance.

0370m E2-2 6/26/87 SL-2727 i

700776