(E-mail Dated 8/12/20) - EPRI Report 3002015906 as Supplement to MPS2 Alternative Request RR-05-06, Dated July 15, 2020
ML20225A139
Person / Time
Site: Millstone Dominion icon.png
Issue date: 08/12/2020
From: Sinha S
Dominion Energy Nuclear Connecticut
To: Richard Guzman
NRC/NRR/DORL/LPL1
Guzman R
Shared Package
ML20225A141 List:
References
EPID L-2020-LLR-0097
Download: ML20225A139 (1)


Text

From: Shayan.Sinha@dominionenergy.com To: Guzman, Richard

Subject:

[External_Sender] EPRI Report 3002015906 Date: Wednesday, August 12, 2020 10:49:53 AM Attachments: EPRI TB for PWR SG CL 1 Nozzle-to-Vessel Welds and CL1 Tubesheet-to-Head, and CL2 Tubesheet-to-Shell Welds 3002015906 (1).pdf

Rich, Please find attached EPRI Report 3002015906, Technical Bases for Inspection Requirements for PWR Steam Generator Class 1 Nozzle-to-Vessel Welds and Class 1 and Class 2 Vessel Head, Shell, Tubesheet-to- Head, and Tubesheet-to-Shell Welds.

We have received EPRIs agreement that it is acceptable for the NRC to docket this Report in ADAMS, in support of the review of the Millstone 2 Alternative Request RR-05-06 (Dominion Serial No. 20-167/NRC ADAMS No. ML20198M682) submitted on July 15, 2020.

Thanks, Shayan Sinha Dominion Energy Nuclear Regulatory Affairs Shayan.sinha@dominionenergy.com (804) 273-4687