From:

Sippel, Timothy To:

Morie, Amaryl A; Brown, Nicholas W.

Cc:

Peterka, Nicholas

Subject:

August 24 NCS Inspection Date:

Wednesday, August 5, 2020 9:59:00 AM Attachments:

Document Request.docx Amaryl, Nick, The purpose of this letter is to notify you that the U.S. Nuclear Regulatory Commission (NRC) Region II staff will conduct a Nuclear Criticality Safety inspection at your facility during the week of August 24, 2020. The inspections will focus on the core inspection procedures described in the NRC Inspection Manual Chapter 2600. The inspectors will use NRC Inspection Procedure (IP) 88015, Nuclear Criticality Safety. The inspectors are myself and Nick Peterka.

I apologize for the late notice, weve been in a state of flux due to the COVID-19 situation.

The current plan for this inspection is that Ill go onsite, while Nick Peterka will conduct the remote portion of this inspection concurrently. In the attached document request we divided the documents between those that Ill be reviewing onsite and those that Nick will be reviewing as part of the remote inspection. If some documents are too difficult to provide remotely or some other difficulty is encountered please let me know. And if our plans change again Ill let you know as soon as I can.

If possible, an entrance meeting should be schedule for 14:00 on August 24, with an exit meeting at 16:00 on August 27. If there are any questions about this inspection or the material requested, please contact me by email or at 404-997-4525.

Thank you, Tim Sippel.

ML20218A451

NUCLEAR CRITICALITY SAFETY INSPECTION DOCUMENT REQUEST SITE: NFS INSPECTION REPORT NUMBER: 2020-003 PRE-INSPECTION VISIT:

NA INSPECTION DATES:

August 24 - August 27, 2020 NRC INSPECTORS:

Lead: Timothy Sippel, Timothy.Sippel@nrc.gov Nicholas Peterka, Nicholas.Peterka@nrc.gov ACCOMPANYING PERSONNEL:

None IDENTIFIED LICENSEE CONTACTS:

Safety & Safeguard Program Manager: Amaryl Morie, aamorie@nuclearfuelservices.com NCS Manager: Nick Brown, nwbrown@nuclearfuelservices.com ASSOCIATED PROCEDURES:

88015 - Nuclear Criticality Safety Note: This is a broad list of the documents the NRC inspectors will be interested in obtaining and reviewing during the inspection visit. The current version of these documents is expected unless specified otherwise. The lead inspector can answer questions regarding specific information needs with licensee staff and may request additional documents.

DOCUMENTATION REQUESTED 1.

Information Requested for Remote Inspection (Please provide via Box, or by mailing to RII) - Peterka a.

The most recent quarterly audit of the NCS program b.

NCS-related PIRCS entries since the last NCS inspection

  • If possible, include information on Con Ops shutdowns related to NCS c.

New and revised NCS procedures d.

Training and Qualification records for newly qualified NCS engineers (if any) e.

ISA procedure f.

General NCS training provided to operators

2 2.

Information Requested for On-Site Inspection Starting August 24 - Sippel a.

New and/or revised NCSEs since last NCS inspection b.

The control flowdowns for the new and/or revised NCSEs since the last NCS inspection c.

NCS inspection reports (a.k.a.: weekly walkdowns) since the last NCS inspection d.

NCSEs and control flowdowns covering the BLEU Prep Facility U-Dissolution and U-Metal Conversion areas (for the equipment, you need not include things like hand carry, process monitoring columns) e.

Functional testing of NCS IROFS in the BLEU Prep Facility U-Dissolution and U-Metal Conversion areas scheduled for the week of August 24th