ML20217Q293

From kanterella
Jump to navigation Jump to search
Submits Rept Re Leaktest Performed on 970812,on Sr-90 Sealed Source Which Indicated Presence of Approx 0.016 Uci of Sr-90.Source Has Been Withdrawn from Svc & Will Return Source to Mfg in Near Future
ML20217Q293
Person / Time
Site: 07000398
Issue date: 08/13/1997
From: Pevey L
NATIONAL INSTITUTE OF STANDARDS & TECHNOLOGY (FORMERL
To:
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 9709020248
Download: ML20217Q293 (2)


Text

_ - _ _ _

f?/4lA 9

~

UNITED STATES DEPARTMENT OF COMMERCE L

National Institute of Sta aderds and Technology kO/

hthersburg, Maryland 200990001

% en i

e August 13,1997 U.S. Nuclear Regulatory Commission Ref: License No. SNM 362 Division of Fuel Cycle Safety and Safeguards Washing'on, D.C. 20555

Dear Sir:

This report is being furnished in accordance with the conditions stated in NRC license No. SNM 362.

A leaktest performed on 8/12/97, on a Sr-90 sealed source, indicated the presence of greater than 0.005 uCi of radioactive material. The sample contained approximately 0.016 uCi of Sr-90. The source tested was manufactured by Be'

'mbH, serial number 0047/97. It consists of a set of 12 brachytherapy type seeds with a total Sr-90 ar

.y of 30 mCl Each seed b cylindrically shaped with dimensions of 0.6mm by 2.5mm.

The leaktest procedure consisted of flushing water through the scurce storage tube and collecting the water for liquid scintillation analysis. Contamination external to the source was limited to the interior of the source storage container and the leaktest sample.

As corrective action, the source has been withdrawn from service and it is planned to return the source to the manufacturer in the near future. The return shipment will comply with all applicable DOT i

regulations. The cause of the source failure is unknown at this time, if you have any questions call Doug Eagleson,301-975-5800, of the NIST Health Physics Group.

Sincerely, 46.d' L.E. Pevey, C f

Occupational Health and Safety Division (Materials License Manager)

]

o i

i cc: NRC Administrator, Region I flll,bf lf koggg ggQ98 C

N

l l

.-.---...c

. - -. ~.

~~...,n

.a.

~ :.-

.- -. c c.

.a

--a.-,...-u

,~...-.,a~.

..n-Healtn Physics, Bldg 245, C125 U.S. DEPARTMENT OF COMMERCE 17.5. O FFIC! AL M A1L*

=

erstatty g

NATIONAL INSTITUTE OF STANDARL,S /JJD TECHNOLOGY s

0

  • GNTHERSBURG. MD 20899 aim
r,'g,

E 0.3 2 5

[1

^

OFFOAL BUSINESS ph aj mm 3

PENALTY FOR PRIVATE USE $300 72304f,0 U.S. PORTAG E :,

U.S. Nuclear Regulatory Comision Division of Fuel Cycle Safety and Safeguards Washington, DC 20555

/

30 g,').

1 l

1 l"l'Ill""l'I"l'I"I'I"'II'I 42 1

L_