Approved 5/13/97 Fcesimila BRP 61004T1

\\

R: vision 4 BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 "ADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1997 THROUGH DECEMBER,1997 GASEOUS EFFLUENTS -VENT STACK RELEASES - CONTINUOUS MODE (CONT.)

l UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l J. IODINE RELEASES l-131:

Ci 8.06E-06 5.71 E-05

<LLD

<LLD l-133:

Ci 8.50E-05 1.47E-04

<LLD

<LLD l-135:

Cl 1.58E-05 2.05E-04

<LLD

<LLD l-132:

Ci

<LLD 1.02E-04

<LLD

<LLD K. PARTICULATE (>8 day half-life) RELEASES Sr-89:

Ci

<LLD

<LLD

<LLD

<LLD Sr 90:

Cl

<LLD

<LLD

<LLD

<LLD Br-82:

Ci

<LLD

<LLD

<LLD 7.87E-07 Co-60:

Ci

<LLD 2.10E-06 2.91E-06 4.67E-06 Sb-125:

Cl

<LLD

<LLD

<LLD

<LLD

)

l LIQUID EFFLUENTS -SUMMATION OF ALL RELEASES L. FISSION AND ACTIVATION PRODUCT RELEASES

1. Total Activity Released:

Ci 4.17E-02 7.50E-02 4.54E-02 7.28E-02

2. Average Concentration uCi/ml 1.83E-08 2.93E-08 1.60E-08 3.28E-08 Released For Quarter.
3. % of 10CFR50 Limits l
a. Quarteriy Whole Body l

l 0.17 l

0.06 l

0.43 l

0.06 l

(1.5 mrem):

l

b. Quarterly Any Organ l

l 0.07 l

0.07 l

0.19 l

0.02 l

[

(5.0 mrem):

c. Annual Whole Body l

l 0.08 l

0.03 l

0.22 l

0.03 l

(3.0 mrem):

d. Annual Any Organ l

l 0.04 l

0.04 l

0.10 l

0.01 l

(10.0 mrem):

9804100118 980401 PDR ADDCK 05000454 R

PDR (9916SS/XLS/051397)

Approved 6/13/97 Fecsimila BRP 6100-6T1 Rsvision 4

(-

i BYRON NUCLEAR POWER STATION UNIT 1 DOCKET NUMBER STN-50-454 l

RADIOACTIVE EFFLUENT RELEASE REPORT JANUARY,1997 THROUGH DECEMBER,1997 LIQUID EFFLUENTS - BATCH MODE l

UNITS l 1st Quarter l 2nd Quarter l 3 d Quarter l 4th Quarter l S. LIQUID EFFLUENTS Fe 55-Cl 1.12E-03 2.62E-03 8.55E-04 6.32E-03 Sr 89:

Cl 1.61E-04 2.62E-04 9.24E-04 3.61E-04 Sr-90:

Cl

<LLD

<LLD

<LLD 5.31E-05 H-3:

. Cl 3.35E+02 1.93E+02 2.16E+02 3.19E+02 Ar-41:

Cl 2.39E-04

<LLD

<LLD-1.09E-03 Cr-51:

Ci 4.73E-04 2.67E-04 4.28E-04 3.58E-04 Mn-54:

Ci 3.29E-04 1.79E-03 6.20E-04 4.07E-04 Fe-59:

Cl 5.04E-04

<LLD

<LLD 1.21E-04 Co-57:

Cl 1.84E-05 1.13E-04 2.02E-06 9.87E-05 Co-58:

Ci 6.52E-03 9.23E-03 1.75E-03 2.30E-02 Co-60:

Cl 1.88E-02 3.36E-02 1.17E-02 7.91 E-03 Zn-65:

Ci

<LLD 9.38E-04 1.37E-04 4.96E-05 Kr-85:

Cl 1.19E-02

- 1.15E-02 3.54E-03 1.04E-02 Kr-85m:

Ci

<LLD

<LLD

<LLD 2.50E-05 Kr-87:

Ci

<LLD

<LUD

<LLD

<LLD I

Kr-88:

Ci

<LLD 2.25E-05

<LLD 2.21E-05 Sr 92:

Cl 5.09E-06 1.04E-04

<LLD

<LLD Nb-95:

C1 2.30E-04 1.28E-03 1.76E-04 7.95E-05 Zr-95:

Ci 9.40E-05 4.16E-04

<LLD 1.20E-05 Zr-97:

Ci

<LLD

<LLD

<LLD 3.13E-06 Mo-99:

Cl 1.61 E-05

<LLD

<LLD-

<LLD Tc-99m:

Ci-

<LLD (LLD

<LLD

<LLD Tc-104:

Ci

<LLD

<LLD

<LLD

<LLD Ag-110m:

Ci 2.64E-05 4.86E-04 4.38E-05

<LLD Sn-113:

Ci

<LLD 2.22F-M

<LLD

-<LLD i

Te-121m:

Ci

<LLD

<LLD

<LLO

<LLD Te-123m:

Ci 2.11 E-04 4.63E-04 9.51 E-05 7.38E-03 Te-125m:

Ci 8.75E-03 9.47E-03 5.30E-04 9.08E-03 Sb-122:

Ci

<LLD

<LLD

<LLD 2.38E-04 Sb-124:

Cl 1.32E-05 4.23E-04 3.19E-04 7.30E-03 Sb-125:

Ci 6.02E-04 1.29E-02 1.68E-02 9.42E-03 Sb.126:

Ci

<LLD 3.62E-06

<LLD 3.45E-05 Report Page 8_ of 2H

-(9916SS/XLS/051397)

Approved SI13/97 -

Fcesim"ils BRP 6100 6T1 Ravision 4 4

BYRON NUCLEAR POWER S RATION UNIT 2 DOCKET NUMBER STM-50-455 RADIOACTIVE EFFLUENT RELEA6 E REPORT

' JANUARY,1997 THROUGH DECEf. IBER,1997 GASEOUS EFFLUENTS -VENT STACK RELEASES CONTINUOUS MODE (CONT.)

l UNITS l 1st Quartor l 2nd Quarter l 3rd Quarter l 4th Quarter l J. LODINE RELEASES l-131:

Ci

<LLD

<LLD

<LLD

<LLD j

1-133:

Cl 4.21E-06

<LLD

<LLD

<LLD l

l-135:

Ci

<LLD

<LLD

<LLD

<LLD L

1-132:

Ci -

2.27E-05

<LLD

<LLD

<LLD l

K. PARTICULATE (>8 day half-life) RELEASES Sr-89:

Ci

<LLD

<LLD

<LLD

<LLD Sr-90:

Ci

<LLD

<LLD

<LLD

<LLD l

Sb-125:

Cl 1.30E-05 1.14E-05

<LLD 3.62E-07 Br-82:

Ci 8.42E-06 4.62E-06 3.47E-06 4.17E-06 Co-60:

Ci

<LLD 1.33E-06 3.97E-06 2.17E-06 l

LIQUID EFFLUENT 8 -SUMMATION OF ALL RELEASES L. FISSION AND ACTIVATION PRODUCT RELEASES

1. Total Activity Released:

Cl 4.17E-02 7.50E-02 4.54E 7.28E-02 2, Average Concentration uCi/ml 1.83E-08 2.93E-08 1.60E-08 3.28E-08 i

Released For Quarter: '-

I

~

l.;

3. % of 10CFR50 Limits
a. Quarterly Whole Body 1

l 0.17 l

0.06 l

0.43 1

0.06 l

(1.5 mrem):

b. Quarterly Any OrDan l

l 0.07 l

0.07 l

0.19 l

0.02 l

(5.0 mrem):

l

c. Annual Whole Body l

l:

0.08 l

0.03 l

0.22 l

0.03 J

lJ (3.0 mrem):

1 ll

. d. Annual Any Organ

-l-l 0.04 l

0.04 l

0.10 l

0.01 l

)

(10.0 mrem):

l Report Page13 of 2R (9916SS/XLS/051397)

Approved 6I13/97 Facsimila BRP 61004T1 R: vision 4

~

BYRON NUCLEAR POWER STATION UNIT 2 DOCKET NUMBER STN-50-455 RADIOACTIVE EFFLUENT RELEASE REPORT

~ JANUARY,1997 THROUGH DECEMBER,1997 4

LIQUID EFFLUENTS - BATCH MODE i

4 l

UNITS l 1st Quarter l 2nd Quarter l 3rd Quarter l 4th Quarter l

- S. LIQUID EFFLUENTS Fe-55:

Cl 1.12E-03

- 2.62E-03 8.55E-04 6.32E-03 Sr-89:

Ci 1.61 E-04 2.62E-04,

9.24E-04 3.61E-04 Sr 90:

Ci

<LLD

<LLD

<LLD 5.31E-05 H-3:

Cl 3.35E+02 1.93E+02 2.16E+02 3.19E+02 Ar-41:

Cl 2.39E.<LLD

<LLD 1.09E-03 Cr-51:

Mn-54:

Ci 4.73E-04 2.67E-04 4.28E-04 3.58E-04 Ci 3.29E-04 1.79E-03 6.20E-04 4.07E Fe-59:

Ci 5.04E-04

<LLD

<LLD 1.21E-04 Co-57:

Ci 1.84E-05 1.13E-04 2.02E-06 9.87E-05 i

I Co-58:

Ci 6.52E-03 9.23E-03 1.75E-03 2.30E-02 Co-60:

Cl 1.88E-02 3.36E-02 1.17E-02 7.91E-03 Zn-65:

Ci

<LLD 9.38E-04 1.37E-04 4.96E-05 Kr-85:

Cl 1.19E-02 1.15E-02 3.54E-03 1.04E-02 Kr-85m:

Cl

<LLD

<LLD

<LLD 2.50E-05 Kr-87:

Ci

<LLD

<LLD

<LLD

<LLD l

Kr-88:

Ci

<LLD 2.25E-05

<LLD 2.21 E-05 Sr-92:

Cl 5.09E-06 1.04E-04

<LLD

<LLD Nb-95:

Ci 2.30E-04 1.28E-03 1.76E-04 7.95E-05 Zr-95:

Ci 9.40E-05 4.16E-04

<LLD 1.20E-05 Zr-97:

Ci

<LLD

<LLD

<LLD 3.13E-06 Mo-99:

Cl 1.61E-05

<LLD

<LLD

<LLD Tc-99m:

Ci

<LLD

<LLD

<LLD

<LLD Tc-104:

Ci

<LLD

<LLD

<LLD

<LLD Ag-110m:

Ci 2.64E 05 4.86E-04 4.38E-05

<LLD Sn-113:

Ci

<LLD 2.22E-04

<LLD

<LLD Te-121m:

Ci

<LLD

<LLD

<LLD

<LLD Te-123m:

Ci 2.11E 04 4.63E-04 9.51E-05 7.38E-03 Te-125m:

Ci 8.75E-03 9.47E-03 5.30E 04 9.08E-03 Sb-12t Ci

<LLD

<LLD

<LLD 2.38E-04 Sb-124:

Cl 1.32E-05 4.23E-04 3.19E-04 7.30E-03 Sb-125:

Ci 6.02E-04 1.29E-02 1.68E-02 9.42E-03 Sb-126:

Ci

<LLD 3.62E-06

<LLD 3.45E-05 Report Page 15 of 28 (9916SS/XLS/051397)'

l

  • DELIVER TO HEALTH PHYSICS
  • AQUATIC Effluents-10CFR50 Listing 31-mar-1998 12:49:40 STATION: BYRON STATION UNIT:

1 PERIOD:

01/01/97 12/31/97 NAME:

THOMPSON REPORT: ANNUAL MODE:

ACTUAL i

J i

i 4

BYRON STATION UNIT ONE ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 INEANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.81E-04 3.37E-04 3.77E-04 5.53E-04 1.85E-03 BODY INTERNAL 5.92E-04 3.38E-04 4.11E-04 5.52E-04 1.89E-03 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.04 0.02 0.03 0.04 3.0 0.06 CRIT. ORGAN (MREM) 5.0 0.01 0.01 0.01 0.01 10.0 0.02 LIVER GI_LLI LIVER LIVER LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

i

BYROM STATION UNIT ONE 1997 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.81E-04 3.37E-04 3.77E-04 5.53E-04 1.85E-03 BODY INTERNAL 5.92E-04 3.3BE-04 4.11E-04 5.52E-04 1.89E-03 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.046 BODY INTERNAL 4.0 MREM 0.047 ORGAN LIVER o

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l

BYRON STATION UNIT ONE ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 CHILD RECEPTOR 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.12E-03 5.77E-04 1.74E-03 7.50E-04 4.18E-03 BODY INTERNAL 3.60E-03 1.15E-03 8.97E-03 1.09E-03 1.46E-02 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.07 0.04 0.12 0.05 3.0 0.14 CRIT. ORGAN (MREM) 5.0 0.07 0.02 0.18 0.02 10.0 0.15 LIVER GI_LLI LIVER LIVER LIVER 1

l RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

l i

)

BYROM STATION UNIT ONE 1997 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 CHILD RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.85E-04 3.39E-04 3.81E-04 5.57E-04 1.86E-03 BODY INTERNAL 5.92E-04 3.44E-04 4.04E-04 5.57E-04 1.89E-03 ORGAN LIVER GI_LLI LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.047 BODY l

INTERNAL 4.0 MREM 0.047 ORGAN LIVER o

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

j l

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

BYRON STATION UNIT ONE ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.52E-03 5.67E-04 3.58E-03 6.29E-04 6.29E-03 BODY INTERNAL 3.58E-03 2.33E-03 9.55E-03 9.07E-04 1.49E-02 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.10 0.04 0.24 0.04 3.0 0.21 CRIT. ORGAN (MREM) 5.Q 0.07 0.05 0.19 0.02 10.0 0.15 LIVER GI_LLI LIVER LIVER LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

BYRON CTATION UNIT ONE f

1997 ANNUAL REPORT

{

PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.06E-04 1.77E-04 2.01E-04 2.91E-04 9.74E-04 BODY INTERNAL 3.11E-04 1.87E-04 2.10E-04 2.95E-04 9.92E-04 ORGAN GI_LLI GI_LLI LIVER GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1997 l

l l

COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.024 l

BODY INTERNAL 4.0 MREM 0.025 ORGAN l

GI LLI l

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

l RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 l

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

1 BYROM STATION UNIT ONE ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUPNTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED C3/31/98 ADULT RECEPTOR IST 2ND 3RD 4Tt!

DOSE. TYPE QUARTER QUARTER QUARTER QUAFTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DOC l

TOTAL 2.59E-03 8.47E-04 6.42E-03 9.48E-04 1.08E-02 l

BODY l

INTERNAL 3.65E-03 3.33E-03 9.44E-03 1.05E-03 1.52E-02

' ORGAN LIVER GI_LLI LIVER LIVER LIVER l

THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.17 0.06 0.43 0.06 3.0 0.36 CRIT. ORGAN (MREM) 5.0 0.07 0.07 0.19 0.02 10.0 0.15 l

LIVER GI_LLI LIVER LIVER LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARL VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l l

l l

)

j l

BYRON STATION UNIT ONE 1997 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 ADULT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 4.34E-04 2.50E-04 2.88E-04 4.12E-04 1.38E-03 BODY INTERNAL 4.41E-04 2.67E-04 2.92E-04 4.18E-04 1.41E-03 ORGAN GI_LLI GI_LLI LIVER GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

%,OF LIMIT TOTAL 4.0 MREM 0.035 BODY INTERNAL 4.0 MREM 0.035 ORGAN GI_LLI o

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

l i

  • DELIVER TO HEALTH PHYSICS
  • l l

31-mar-1998 12:54:23 Total Effective Dose Equivalent - 10CFR20 Listing l

STATION: BYRON STATION UNIT:

1 PERIOD:

01/01/97 12/31/97 NAME:

THOMPSON REPORT: ANNUAL MODE:

ACTUAL For ADULT dose calculations, the included pathways are:

INHALATION MILK l

PRODUCE VEGETABLES l

MEAT GROUND DEPOSITION FISH WATER SKYSHINE UHOLE BODY Airborne Effluents are complete from 01/01/97 to 12/31/97 Aquatic Effluents are complete from 01/01/97 to 12/31/97 Skyshine entries are complete from to 1

i i

i I

~

BYROM STATION UNIT ONE 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/97 TO 12/31/97 CALCULATED 03/31/98 1.

10 CFR 20.1301 {a) (1) Compliance i

Total Effective Dose Egivalent, mrem /yr 9.35E-03 10 CFR 20.1301 (a) (1) limit mrem /yr

.100.0

% of limit 0.01 I

Compliance Summary - 10CFR20 i

ist 2nd 3rd 4th

% of Qtr Qtr Qtr Qtr Limit TEDE 2.02E-03 1.26E-03 4.64E-03 1.42E-03 0.01 RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

l

-BYRON STATION UNIT ONE 10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/97 TO 12/31/97 CALCULATED 03/31/98 2.

10 CFR 20.1301 (d)/40 CFR 190 Compliance I

Dose Limit e of (mrem)

(mrem)

Limit Whole Body Plume 3.08E-05 (DDE)

Skyshine 0.00E+00 Ground 3.34E-04 Total 3.65E-04 25.0 0.00 organ Dose Thyroid 7.75E-03 75.0 0.01 l

(CDE)

Gonads 9.01E-03 25.0 0.04 i

l Breast 7.69E-03 25.0 0.03 Lung 7.80E-03 25.0 0.03 l

l Marrow 8.47E-03 25.0 0.03 Bone 1.09E-02 25.0 0.04 Remainder 1.02E-02 25.0 0.04 CEDE 8.9BE-03' i

TEDE 9.35E-03 100.0 0.01 RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

  • DELIVER TO HEALTH PHYSICS
  • AQUATIC Effluents-10CFR50 Listing 31-mar-1998 12:51:12 STATION: BYRON STATION UNIT:

2 PERIOD:

01/01/97 12/31/97 MAME:

THOMPSON REPORT: ANNUAL MODE:

ACTUAL I

i i

i

)

I.

1 BYROM STATION UNZT TUO ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 I

INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPF QUARTER QUARTER QUARTER QUARTER ANNUAL

}

JAN-MAR APR-JUN JUL-SEP OCT-DEC l

[

TOTAL 5.81E-04 3.37E-04 3.77E-04 5.53E-04 1.85E-03 BODY INTERNAL 5.92E-04 3.38E-04 4.11E-04 5.52E-04 1.89E-03 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 I

COMPLIANCE STATUS - 10 CFR 50 APP. I i

--- -------- % OF APP I. ------------

I l

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF l

OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.04 0.02 0.03 0.04 3.0 0.06 CRIT. ORGAN (MREM) 5.0 0.01 0.01 0.01 0.01 10.0 0.02 LIVER GI_LLI LIVER LIVER LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION l'3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

I 1

l

r BYRON STATIOH UNIT TWO 1997 ANNUAL REPORT i

PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 l

INFANT RECEPTOR I

IST 2ND 3RD 4TH l

DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.81E-04 3.37E-04 3.77E-04 5.53E-04 1.85E-03 BODY INTERNAL 5.92E-04 3.38E-04 4.11E-04 5.52E-04 1.89E-03 I

ORGAN i

LIVER GI_LLI LIVER LIVER LIVER j

i THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 TYPE' ANNUAL LIMIT

%,OF LIMIT TOTAL 4.0 MREM 0.046 BODY INTERNAL 4.0 MREM 0.047 ORGAN LIVER c

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

I RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

BYRON STATION UNIT TWO ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/96 CHILD RECEPTOR IST 2ND 3RD 4TH DOSE T1PE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.12E-03 5.77E-04 1.74E-03 7.50E-04 4.18E-03 BODY INTERNAL 3.60E-03 1.15E-03 8.97E-03 1.09E-03 1.46E-02 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

l QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I 1

TOTAL BODY.(MREM) 1.5 0.07 0.04 0.12 0.05 3.0 0.14 CRIT. ORGAN (MREM) 5.0 0.07 0.02 0.18 0.02 10.0 0.15 LIVER GI_LLI LIVER LIVER LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

i i

l I

j4 BYRON STATION UNIT TWO 1997 ANNUAL REPORT l

PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • l PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 i

CHILD RECEPTOR 1

IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL l

JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 5.85E-04 3.39E-04 3.81E-04 5.57E-04 1.86E-03 l

BODY INTERNAL 5.92E-04 3.44E-04 4.04E-04 5.57E-04 1.89E-03 i

ORGAN LIVER GI_LLI LIVER GI_LLI LIVER i

THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MRD4 0.047 BODY l

l INTERNAL 4.0 MREM 0.047 1

ORGAN 1

l 1

l LIVER l

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION NANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 I

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

l l

\\

l l

I BYRON STATION UNIT TWO I

ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 TEENAGER RECEPTOR l

IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL l

JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.52E-03 5.67E-04 3.58E-03 6.29E-04 6.29E-03 I

BODY INTERNAL 3.58E-03 2.33E-03 9.55E-03 9.07E-04 1.49E-02 ORGAN LIVER GI_LLI LIVER LIVER LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I


E OF APP I.

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.10 0.04 0.24 0.04 3.0 0.21 CRIT. ORGAN (MREM) 5.0 0.07 0.05 0.19 0.02 10.0 0.15 l

LIVER GI_LLI LIVER LIVER LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 i

ODCM DATABASE VERSION 1.1 January 1995 j

l l

t

BYRON STATION UNIT TWO 1997 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 3.06E-04 1.77E-04 2.01E-04 2.91E-04 9.74E-04 BODY INTERNAL 3.11E-04 1.87E-04 2.10E-04 2.95E-04 9.92E-04 ORGAN j

GI_LLI GI_LLI LIVER GI_LLI GI_LLI THIS'IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 l

l TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.024 BODY INTERNAL 4.0 MREM 0.025 ORGAN GI_LLI l

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE I

COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l I

l

(

BYRON STATION UNIT T50 ACTUAL 1997 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 l

ADULT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.59E-03 8.47E-04 6.42E-03 9.48E-04 1.08E-02 i

BODY INTERNAL 3.65E-03 3.33E-03 9.44E-03 1.05E-03 1.52E-02 l

ORGAN LIVER GI_LLI LIVER LIVER LIVER 1

THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 10 CFR 50 APP. I

% OF APP I.

l QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.17 0.06 0.43 0.06 3.0 0.36 CRIT. ORGAN (MREM) 5.0 0.07 0.07 0.19 0.02 10.0 0.15 l

LIVER GI_LLI LIVER LIVER LIVER l

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 1

ODCM DATABASE VERSION 1.1 January 199 l

t l

l-BYRON STATION UNIT TUO 1

1997 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/97 TO 12/31/97 CALCULATED 03/31/98 ADULT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 4.34E-04 2.50E-04 2.88E-04 4.12E-04 1.38E-03 BODY l

INTERNAL 4.41E-04 2.67E-04 2.92E-04 4.18E-04 1.41E-03 l

ORGAN l

GI_LLI GI_LLI LIVER GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1997 COMPLIANCE STATUS - 40 CFR 141 TYPE' ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.035 BODY l

INTERNAL 4.0 MREM 0.035 l

ORGAN j

GI_LLI 1

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL. THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

l t

L

r 4

  • DELIVER TO HEALTH PHYSICS
  • 31-nar-1998 12:55:24 Total Effective Dose Equivalent - 10CFR20 Listing l

STATION: BYRON STATION l

UNIT:

2 PERIOD:

01/01/97 12/31/97 NAME:

THOMPSON REPORT: ANNUAL MODE:

ACTUAL l

i For ADULT dose calculations, the included pathways are:

INHALATION MILK PRODUCE VEGETABLES MEAT GROUND DEPOSITION FISH WATER SKYSHINE l

WHOLE BODY Airborne Effluents are complete from 01/01/97 to 12/31/97 l

Aquatic Effluents are complete from 01/01/97 to 12/31/97 Skyshine entries are complete from to i

l I

i i

I l

\\,

~

BYROM STATION UNIT TWO l'

10 CFR 20 COMPLIANCE ASSESSMENT PERIOD OF ASSESSMENT 01/01/97 TO 12/31/97 CALCULATED 03/31/98 i

l 1.

10 CFR 20.1301 (a) (1) Compliance I

Total Effective Dose Egivalent, mrem /yr 8.71E-03 1

10 CFR 20.1301 (a) (1) limit mrem /yr 100.0 l

% of limit 0.01 l

l Compliance Summary - 10CFR20 1st 2nd 3rd 4th

% of l

Qtr Qtr Qtr Qtr Limit TEDE 2.02E-03 1.23E-03 4.63E-03 8.33E-04 0.01 RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

I l

l l

l t

i I

i i

]

4 BYRON STATION UNIT TWO 10 CFR 20 COMPLIANCE _ ASSESSMENT PERIOD OF ASSESSMENT 01/01/97 TO 12/31/97 CALCULATED 03/31/98 2.

30 CFR 20.1301 (d)/40 CFR 190 Compliance Dose Limit

% of (mrem)

(mrem)

Limit j

t Whole Bcdy Plume 2.67E-05 (DDE)

Skyshine 0.00E+00 Ground 3.11E-05

)

Total 5.78E-05 25.0 0.00 Organ Dose Thyroid 7.39E-03 75.0 0.01 l

(CDE)

Gonads 8.69E-03 25.0 0.03 I

Breast 7.37E-03 25.0 0.03 Lung 7.45E-03 25.0 0.03 Marrow 8.15E-03 25.0 0.03 Bone 1.06E-02 25.0 0.040 Remainder 9.89E-03 25.0 0.04 CEDE 8.66E-03' TEDE 8.71E-03 100.0 0.01 RESULTS BASED UPON: ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 I

i l

i I

1 l

j