ML20217P305

From kanterella
Jump to navigation Jump to search
Forwards List of Triga Research Reactor Components Available for Acquisition.Location of Each Component,Provided
ML20217P305
Person / Time
Site: 05000606, University of Utah
Issue date: 04/30/1998
From: Hamm J
ARKANSAS TECH UNIV., RUSSELLVILLE, AR
To: Alexander Adams
NRC
References
NUDOCS 9805060222
Download: ML20217P305 (3)


Text

Sb-67 M-Arkansas SD - 6?O(o N Tech n:!K s w.cs, s %

5 University w,,y.

i Russellville, Arkansas 72801-2222 u-. n -

April 30,1998 Mr. Al Adams U.S. Nuclear Regulatory Commission Mail Stop O-11-B-20 Washington, DC 20555 Dear Mr. Adams Enclosed is a list of the TRIGA research reactor components. Allitems are held by Arkansas Tech University with the exception ofitems 18,38 and 39. The control console (item 18) has been transferred to the VA Hospital in Omaha, Nebraska. A new fission chamber and a new uncompensated ion chamber (items 38 and 39) are at General Atomics, San Diego, California.

Arl:ansas Tech University is directing General Atomics to ship items 38 and 39 to the University of Utah. The remaining components are scheduled for a May 8,1998 departure from Russellville, Arkansas and a May 11,1998 arrival at the University of Utah in Salt Lake City.

If additional information is needed, please contact my office.

Sincerely Yours, k

W Jac Hamm Dean Copy: Dr. John Krohn Dr. Mike Slaughter j!

File

/

(,]ji

(

9805060222 980430 PDR ADOCK 05000407 P

PDR

Reactor Components Available for Acquisitian kTEM i

1.

Aluminum Clad Graphite Reflector and Stand l

2.

Aluminum Rotary Specimen Rack 3.

Aluminum Bottom Grid Plate 4.

Aluminum Top Grid Plate 5.

2 Compensated Ion Chambers, in case w/ extensions 6.

1 Uncompensated lon Chamber, in case w/ extension 7.

Fission Chamber (2 gm U-235), in case w/ extension and preamp 8.

3 Control rod guide tubes l

9.

Aluminum Central Thimble Assy 10.

4 Aluminum Fuel Storage Racks 11.

Am-Be neutron source with holder 12.

3 aluminum clad Boron Control Rod w/ extensions 13.

Pneumatic control rod drive assembly (refurbished by GA) 14.

2 electromechanical control rod drives (refurbished by GA) 15.

Rotary specimen rack drive assy (motorized) 16.

Rotary Specimen Access Tube 17.

Fishing Rod with solenoid hook 18.

Control Console complete (refurbished by GA) 19.

Fuel inspection tool with adaptors 20.

Fuel handling tool 21.

11 aluminum graphite reflector elements 22.

lon chamber support ring 23.

3 underwater lights 24.

Guide tube removal tool 25.

Central channel assembly 26.

6 tank covers

~

ADDITIONAL 27.

Heat exchanger 28.

Primary pump 29.

Secondary pump 30.

Demineralizer L

31.

Standby power supply l

32.

Area monitor 33.

Particulate monitor 34.

AR-41 monitor

\\

j 35.

Intrusion alarm 36.

Pneumatic sample transfer system 37.

Manuals and documentation for above items

)

38.

New fission chamber k

39.

New uncompensated ion chamber j

]

I i

1 4

l J