ML20217N432

From kanterella
Jump to navigation Jump to search
Requests That NRC Review & Approve Westinghouse WCAP-14882 RETRAN-02 Modeling & Qualification for Westinghouse Pressurized Water Reactor Non-LOCA Safety Analysis, by 981201
ML20217N432
Person / Time
Site: Farley  Southern Nuclear icon.png
Issue date: 03/27/1998
From: Dennis Morey
SOUTHERN NUCLEAR OPERATING CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9804090099
Download: ML20217N432 (1)


Text

..

Dave Mir;y S:uthern Nucle:r Mce Pre';ident Op: rating Comp::ny Farley Project P.O. Box 1295 l

Birmingham. Alabama 35201 g,",,.,

Tel 205.992.5131 k

EOUTHERN h i

March 27,1998 gg Energy to Serve YourWorld

Docket Nos.:

50-348 50-364 U. S. Nuclear Regulatory Commission ATTN.: Document Control Desk Washington, DC 20555 Joseph M. Farley Nuclear Plant Request For NRC Review Of WCAP-14882, Rev. O, Dated June 6,1997

'M-02 Mc jeling and Qualification For Westinnhouse Pressuriud Water Reactor Non-LOCA Safety Analysis" Ladies and Gentlemen:

WCAP-14882, Rev. O, dated June 6,1997, titled, "RETRAN-02 Modeling and Qualification for Westinghouse Pressurized Water Reactor Non-LOCA Safety Analysis" was submitted to the NRC by Westinghouse for review and approval. Southern Nuclear Ope..ving Company (SNC) will use the Westinghouse RETRAN analysis methodology for modehng non-LOCA events to support the i

Steam Generator Replacement (SGR) Project for Joseph M. Farley Nuclear Plant (FNP). SNC j

will be submitting a proposed amendment to the Facility Operating Licenses and Technical i

Specifications for FNP Unit I and Unit 2 to support the SGR project. 'Ihis amendment is plarmed to be submitted in January 1999. As such, SNC formally requests that the Westinghouse WCAP-14882 be reviewed and approved by December 1,1998. Please notify SNC if approval of WCAP-14882 by the requested date is not possible.

I Should you have any questions, please advise.

p Respectfully submitted,

((Al ~l7W"l}'

/f()O l Dave Morey CHM / cit:retran. doc cc:

Mr. L. A. Reyes, Region II Administrator Mr. J. I. Zimmerman, NRR Project Manager Mr. T. M. Ross, Plant Sr. Resident hispector 9804090099 980327 PDR ADOCK 0500 0

P