ML20217L212

From kanterella
Jump to navigation Jump to search
FRN for Final SLR-ISG-2021-01-PWRVI, Updating Aging Management Criteria for Reactor Vessel Internal Components for Pressurized-Water Reactors
ML20217L212
Person / Time
Issue date: 01/13/2021
From: Caldwell R
NRC/NRR/DNRL
To:
Mitchell J
References
NRC-2020-0153, SLR-ISG-2021-01-PWRVI
Download: ML20217L212 (5)


Text

[7590-01-P]

NUCLEAR REGULATORY COMMISSION

[NRC-2020-0153]

Updated Aging Management Criteria for Reactor Vessel Internal Components for Pressurized-Water Reactors AGENCY: Nuclear Regulatory Commission.

ACTION: Interim staff guidance; issuance.

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) is issuing Interim Staff Guidance (ISG) SLR-ISG-2021-01-PWRVI, Updated Aging Management Criteria for Reactor Vessel Internal Components for Pressurized-Water Reactors. This ISG updates the aging management criteria for pressurized-water reactor (PWR) vessel internals components in the NRCs subsequent license renewal (SLR) guidance documents. Specifically, the ISG revises guidance contained in NUREG-2191, Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report, and NUREG-2192, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants. This ISG is intended to facilitate preparation of SLR applications by clarifying existing guidance for aging management and adding new guidance, which also will facilitate the NRC staffs review of SLR applications.

DATES: This guidance is effective on February 18, 2021.

ADDRESSES: Please refer to Docket ID NRC-2020-0153 when contacting the NRC about the availability of information regarding this document. You may obtain publicly available information related to this document using any of the following methods:

Federal Rulemaking Web Site: Go to https://www.regulations.gov and search for Docket ID NRC-2020-0153. Address questions about Docket IDs in Regulations.gov to Jennifer Borges; telephone: 301-287-9127; email:

Jennifer.Borges@nrc.gov. For technical questions, contact the individual listed in the FOR FURTHER INFORMATION CONTACT section of this document.

NRCs Agencywide Documents Access and Management System (ADAMS): You may obtain publicly available documents online in the ADAMS Public Documents collection at https://www.nrc.gov/reading-rm/adams.html. To begin the search, select Begin Web-based ADAMS Search. For problems with ADAMS, please contact the NRCs Public Document Room (PDR) reference staff at 1-800-397-4209, 301-415-4737, or by email to pdr.resource@nrc.gov. For the convenience of the reader, instructions about obtaining materials referenced in this document are provided in the Availability of Documents section.

Attention: The PDR, where you may examine and order copies of public documents, is currently closed. You may submit your request to the PDR via e-mail at pdr.resource@nrc.gov or call 1-800-397-4209 or 301-415-4737, between 8:00 a.m. and 4:00 p.m. (EST), Monday through Friday, except Federal holidays.

FOR FURTHER INFORMATION CONTACT: Jeffrey Mitchell, Office of Nuclear Reactor Regulation, U.S. Nuclear Regulatory Commission, Washington DC 20555-0001, telephone: 301-415-0833; email: jeffrey.mitchell2@nrc.gov.

SUPPLEMENTARY INFORMATION:

I. Background On August 3, 2020 (85 FR 46735), the staff requested public comments on draft SLR-ISG-PWRVI-2020-XX, Updated Aging Management Criteria for Reactor Vessel Internal Components for Pressurized-Water Reactors. The NRC received comments from the Electric Power Research Institute, Materials Reliability Program (EPRI MRP) by letter dated September 1, 2020 (ADAMS Accession No. ML20245E539), and from the Nuclear Energy Institute by letter dated September 2, 2020 (ADAMS Accession No. ML20246G654). No other comments were submitted. The NRC staff considered

those comments in developing the final version of the ISG. The staffs responses to the comments are provided in Appendix H, Disposition of Public Comments, of the final ISG.

This ISG updates NUREG-2191, Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report, and NUREG-2192, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants. NUREG-2191 and NUREG-2192 were published in July 2017, and a full review and revision to these documents is not scheduled to be performed for several years.

The staff has reviewed the first three subsequent license renewal applications (SLRAs) that were based on the above guidance documents. During these reviews, the staff and applicants identified improvements to the guidance that would assist in preparing and reviewing future SLRAs more effectively and efficiently. This ISG provides an interim update to NUREG-2191 and NUREG-2192 to implement these improvements.

This ISG is not intended for standalone use. It provides revisions to NUREG-2191 and NUREG-2192 sections and tables that supersede the content in the NUREGs and is intended to be used within the context of the NUREGs. The revisions captured in this ISG include:

updates to GALL-SLR Report aging management program XI.M16A, PWR Vessel Internals; changes to aging management review items in NUREG-2191 tables and corresponding summary tables in NUREG-2192; new aging management review items in NUREG-2191 tables and corresponding summary tables in NUREG-2192; changes to NUREG-2192 further evaluation guidance sections; updates to references listed in affected NUREG-2191 sections; and editorial corrections to relevant sections.

II. Availability of Documents The documents identified in the following table are available to interested persons in ADAMS, as indicated.

DOCUMENT ADAMS ACCESSION NO.

NUREG-2191, Generic Aging Lessons Learned for Subsequent License Renewal (GALL-SLR) Report ML16274A389 (Vol. 1)

ML16274A399 (Vol. 2)

NUREG-2192, Standard Review Plan for Review of Subsequent License Renewal Applications for Nuclear Power Plants ML16274A402 Draft SLR-ISG-PWRVI-2020-XX, Updated Aging Management Criteria for Reactor Vessel Internal Components for Pressurized-Water Reactors ML20156A343 Final SLR-ISG-2021-01-PWRVI, Updated Aging Management Criteria for Reactor Vessel Internal Components for Pressurized-Water Reactors ML20217L203 March 28, 2019, Summary of Category 2 Public Meeting on Lessons Learned from the Review of the First Subsequent License Renewal Applications ML19112A206 Summary of December 12, 2019, Category 2 Public Meeting on Lessons Learned from the Review of the First Subsequent License Renewal Applications ML20016A347 February 20, 2020, Summary of Category 2 Public Meeting on Lessons Learned from the Review of the First Subsequent License Renewal Applications ML20076E074 Summary of March 25, 2020 Meeting with Industry Related to Revisions to Subsequent License Renewal Guidance Documents ML20107F702 Summary of April 3, 2020, Meeting with Industry Regarding Changes to Subsequent License Renewal Guidance Documents ML20107F733 Summary of April 7, 2020, Meeting with Industry Regarding Revisions to the Subsequent License Renewal Guidance Documents ML20107F699 Comment Letter (1) of Christopher Koehler and Brian Burgos, on behalf of the Electric Power Research Institute,

Subject:

Industry Comments to Draft Interim Staff Guidance (ISG)-

SLR-ISG-PWRVI-2020-XX ML20245E539

Comment Letter (2) of Peter W. Kissinger, on behalf of Nuclear Energy Institute,

Subject:

Comments on the proposed changes to subsequent license renewal document SLR-ISG-PWRVI-2020-XX ML20246G654 III. Backfit Discussion This ISG intends to revise guidance for the NRC staff reviewing SLRAs and for prospective applicants in preparing SLRAs. Issuance of this ISG does not constitute a backfit as defined in section 50.109(a)(1) of title 10 of the Code of Federal Regulations (10 CFR) and is not otherwise inconsistent with the issue finality provisions in 10 CFR part 52. As discussed in the Backfitting section of the final ISG, the ISG positions do not constitute backfitting inasmuch as the ISG is guidance directed to the NRC staff with respect to its regulatory responsibilities and to applicants who choose to follow the guidance. Applicants and potential applicants are not, with certain exceptions, the subject of either the backfit rule or any issue finality provisions under 10 CFR part 52. The NRC staff has no intention to impose the ISG positions on existing nuclear power plant licensees either now or in the future (absent a voluntary request for a change from the licensee).

IV. Congressional Review Act This ISG is a rule as defined in the Congressional Review Act (5 U.S.C. 801-808). However, the Office of Management and Budget has not found it to be a major rule as defined in the Congressional Review Act.

Dated: January 13, 2021.

For the Nuclear Regulatory Commission.

/RA/

Robert Caldwell, Deputy Director, Division of New and Renewed Licenses, Office of Nuclear Reactor Regulation.