ENCLOSURE 2
U.S. NUCLEAR REGULATORY COMMISSION
REGION I
Enforcement Conference Report No.
150-00038\\98-001
Docket No.
150-00038
RI License No.
Licensee:
911elsch Eno neerino. Inc.
35 Frances avenue
Cranston. Rhode Island 02910-2211
Enforcement Conference at:
Reaion I. Kina of Prussia. Pennsylvania
Enforcement Conference Conducted: Aoril 21.1998
/
/
k/22-
P
Prepared by:
. .
Eric H.
Reber'
' Date
'
Health Physicist
Approved By:
P
d.b
f(R!@
( Date
fFrancisM.00stello,Ct11ef
Nuclear Materials Safety Branch 3
Division of Nuclear Materials Safety
Summary: The findings documented in our letter dated A)ril 3,1998 were
discussed. The licensee presented its perspective on t1e root causes of the
violations and described corrective actions taken or planned. The NRC
Enforcement Policy was, explained.
7 F 8?n s !"8Af
.
l*
l
l
DETAILS
,
1.
Persons Attendina
Thielsch Enaineerina. Inc.
Nancy Hoffman, Vice President
Tony Varrecchione, Vice President
David Duda, Manager Nondestructive Testing Department
Bruce MacLure Manager Laboratory Services Department and Quality
Assurance Manager
Nuclear Reaulatory Commission
,
George Pangburn, Deputy Director Division of
Nuclear Materials Safety
Daniel Holody, Manager, ORA Technical Staff
Brad Fewell, Regional Attorney
Judith Joustra, Acting Branch Chief
Eric Reber Health Physicist
2.
Conference Sumary
Introductions were made, and the representatives of Thielsch
Engineering, Inc. were welcomed to Region I by Mr. Pangburn. Mr.
Pangburn explained the purpose of the conference which was to discuss
the findings of the NRC inspection conducted on March 9,1998. Mr.
Reber reviewed the apparent violations.
Ms. Hoffman admitted the violations and stated that Thielsch has never
had an incident of this nature. Mr. MacLure then explained the root
causes for the violations and the licensee's immediate and long term
corrective actions in detail.
Mr. Pangburn stressed the significance of these violations.
Mr. Holody outlined the NRC's enforcement options.
,