U

o

p* '" cw

UNITED STATES

,/

h,

NUCLEAR REGULATORY COMMISSION

'g ,(N

,.3

7

REGloN W

( t,

-

!

B01 WARREV 'lLLE ROAD

/

.

ustt. itur mm2-ust

,

.....

Oc

1, 1997

1

Mr. John K. Wood

Vice President Nuclear

Davis Besse Nuclear Power Station

Centerior Service Company

5501 North State Route 2

Oak Harbor, OH 43449

.

SUBJECT: NRC INSPECTION REPORT 50-346/97009(DRP); NOTICE OF VIOLATION

Dear Mr. Wood:

On August 18,1997, the NRC completed an inspection at yout. Davis Besse site. The

enclosed report presents the results of that inspection.

Two violations of NRC requirements were identified during this inspection. The fir'.t violation

involved a " Conduct of Operations" procedure that granted the shift supervisor unilateral

authority to allow procedural steps to be performed out-of order under certain conditions.

This authority is not consistent with the requirements of the Davis Besse Technical

Specifications that require, for a procedure change, a second review and approval by

another member of your management staff. This violation is of particular concern because

the temporary procedure change process was circumvented by an approved procedure,

indicating a lack of staff understanding and appreciation for Technical Specification

requirements.

The second violation involved a failure to .mplement adequate interim corrective actions

associated with a probabilistic safety assessment report for a Circulating Water system

linebreak. The probabilistic safety assessment report, issued May 1996, identified that

operations personnel would have insufficient time to respond to a worst case Circulating

Water linebreak before the resultant flooding caused a complete loss of feedwater, including

auxiliary feedwater. While Davis Besse's staff took substantial corrective action to reduce

the probability of the event occurring, little was done in the way of immediate actions to

minimize the consequences of the accident.

These violations are cited in the enclosed Notice of Violation, and the circumstances

surrounding the violations are described in detailin the enclosed report Please note that

I(

you are required to respond to this letter and should follow the instructions specified in the

enclosed Notice when preparing your resporse. The NRC will use your responso, in part, to

determine whether further enforcement action is necessary to ensure compliance with

regulatory requirements.

9710140264 971001

11I Iul1Il ldi,1W@I t}ilflilig!I,Ilim ,llIll l

ll11111111111111

P!/R

ADOCK 05000346

O

PDR

.

,

._ _

_ _ _ . _ _ _ . - _ - _ _ _ - _ _ _ _ _

_ _ _ . -

_

,

.

.

J. K. Wood

2

i

In accordance with 10 CFR 2.700 of the NRC's " Rules of Practice," a copy of this letter and

Its enclosures will be placed in the NRC Pub!!c Document Room (PDR).

'

Sincerely,

/s/ mrc L. papas for

,

Geoffrey E. Grant, Director

i

Division of Reactor Projects

Docket No.: 50-346

License No.: NPF 3

Enclosures:

1. Notice of Violation

2. Inspection Report 50-346/97009

cc wh nel:

John P. Stetz, Senior

Vice President Nuclear

J. H. Lash, Plant Manager

J. L Freels, Manager

Regulatory Affairs

State Liaison Officer, State

of Ohio

Robert E. Owen, Ohlo

Department of Health

C. A. Glazer, State of Ohio,

Public Utilities Commission

Distribution:

Docket File w/encls

DRP w/encls

PUBLIC IE-01 w/encls

SRI Davis Besse w/encls

OC/LFDCB w/encls

A. B. Beach w/encls

Project Manager, NRR w/encls

Deputy RA w/encls

Rlli Enf. Coordinator w/encls

Rlli PRR w/encls

CAA1 w/enci (E mail)-

DRS (2) w/encls

TSS w/encls

DOCDESK(E mail)

DOCUMENT NAME: R:\\lNSPRPTS\\ POWERS \\DAVi\\DAV97009 DRP

To receive a copy of this docummit, indicate in the box "C" = Copy without attach /enct "E"

= Copy with attach /enci "N" = No copy

OFFICE

Rlli

Rlli

Rlli

Rlli

NAME

Campbell /cb

Wright

Grant 8

df

DATE

9/ 24 /97

9/ 7,f /97

h / /97

'

0FFICIAL RECORD COPY

.

- .

- . .

- . - .

Y