ML20217G737
| ML20217G737 | |
| Person / Time | |
|---|---|
| Site: | 07000364, 07003085 |
| Issue date: | 08/23/1999 |
| From: | Craig D AFFILIATION NOT ASSIGNED |
| To: | Dreier T PENNSYLVANIA, COMMONWEALTH OF |
| References | |
| NUDOCS 9910210344 | |
| Download: ML20217G737 (3) | |
Text
<.
gonM l r m
[
B&W Services Inc.
a Meoermott company R. D.1, Box 355 x
e J,
Vandergrift, PA 15690 (724) 845-2808 CERTIFIED hiAll # Z 024 804 555 August 24,1999 f
q 0 r) g hir. Tim Dreier J
Pennsylvania Department of Environmental Protection Southwest Region: Water Quality Program hianager 400 Waterfront Drive Pittsburgh, PA 15222
Subject:
NPDES Stormwater Permit Parks Township Facility, PAR 236113.
Project Unit C Excavation Stormwater Run Off Sampling Results - July 1999 Reference (1)
Letter, from T V. Dreier, DEP, to W. F. Heer, BWSI, RE: E&S Plan /Stormwater Runotf for Project Unit C Excavations - Discharge Authorization, dated February 26,1999 (2)
Letter, from T. V. Dreier, DEP, to W. F. Heer, BWSI, RE: NPDES PAR 236t l3, i
Storm Water Only Discharges, dated April 15,1999 (3)
Letter from D. W. Craig, BWSI, to T. V. Dreier, DEP, RE: Project Unit C Excavation sequence and Sampling Requirements Claritication, dated June 2,1999 Enclosure (1)
Data Reporting Form-Temporary Discharge, Location: Outfall 001, j
Period: July 1999
)
Dear hir. Dreier:
BWSI, Parks Township Facility is submitting Enclosure (1) in accordance with the reporting recuirements of the Reference (1) Temporary Discharge Authorization. It should be noted that of the six stormwater run off sampling k) cations specified in Reference (1), flow was present only at the Outfall 001 location, during the July sampling evolutions, conducted at the twice weekly periodicity specified in Reference (2). As discussed in Reference (3), the East Drain and the West Drain sampling locations have been permanently plugged, and the
" riprap outlet protection within the Dry Run Area" was not yet constructed during the month of July. Due to the current drought conditions no tiow was available at the upgradient diversion channel or at the down gradient diversion chranel, during the July sampling evolutions.
Should you have any questions concerning our sampling protocol or methodology, please contact me at 724-842-1412.
Sine ely,
/
9910210344 990824 M
V
{DR ADOCK 07000364 AV. Craig, y ger PDR Environmentaldnety & Health h
gW60 4Q thss tuo f
j g w j
I DATA REPORTING FORM - TEMPORARY DISCHARGE n
.A Company Name: B&W Services, Inc.
Facility Name:l Parks Environmental Restoration Project Location: Parks Townshi, OUTFALL 001 P
County: Armstrong For the period:
JULY 1999 Allowable Limits
- Sample Analysis Monthly Avg.
Instant. Max.
Monthly Avg.
Instant. Max.
Flow (gpm)
Monitor / Report 1.13 gpm 1.25 gpm Total Suspended Solids Monitor / Report 44 mg/l_
44 mg/l Oil & Grease '
Monitor / Report 45.0 mg/l 4.5.0 mg/l Total Dissolved Solids Monitor / Report 187 mg/l 192 mg/l Trichloroethane (TCE)-
Monitor / Report 4 5.0 ug/i
<. 5. 0 ug/1
.PCBs Monitor / Report 4 1.0 ug/l
< 1.0 ug/l pH Monitor / Report 7.45 7.47 pH (S.U.)
Between 6.0 and 9.0 at all times All units are in mg/l unless otherwise noted.
- 1. The average of all the grab sample analytical results during a calendar month.
- 2. The analytical results of any single grab sample must comply with the limitation.
)
s y
DOUGLAS.W. CRAIG.
[h 4m h/,7f[fjf
/
L(ate 7 Name of Responsible Official -
'Sibturg
T o
g w
'4 cc:, Mr. Terry Pallas O
" Pennsylvania Department of Environmental Protection 4
Southwest Region Chief of Operations. Water Management Program 400 Waterfront Drive Pittsburgh, PA 15222 Mr Ronald Schwartz Pennsylvania Department of Environmental Protection.
Southweat Region Chief of Permits, Water Management Program 400 Waterfront Drive Pittsburgh, PA 15222 Ms. Kareen Milcic -
Pennsylvania Department of Environm:,ntal Protecdon Southwest Region, Water Management Program 400 Waterfront Drive Pittsburgh, PA 15222 Mr. Fredrick G. Brandt, Water Quality Specialist Pennsylvania Department of Environmental Protecbon Greensburg Distict Offee RR 2, Box 603-C Greensburg, PA 15601-8739 Mr. John J. Matviya Pennsylvania Department of Environmental Protection Southwest Region Environmental Cleanups Program Manager 4
400 Waterfront Drive I
Pittsburgh, PA 15222-4745 t Mr'. Dominick A. _Orlando, Project Manager' Low LevelWaste and Decommissioning Projects Branch MS T8F 37 Division of Waste Management '
I Offee of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission.
Washington, D.C. 20555 I