e y Ente gy Operations,Inc.

Killona. LA 70066 Tel 504 739 6242 Early C. Ewing,lil

. f a Safety & Regulatory AMaira W3F1-98-0054 A4.05 PR March 30,1998 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555

Subject:

Waterford 3 SES Docket No. 50-382 License No. NPF-38 Personnel Monitoring Reports

)

Gentlemen:

Attached are the following 1997 personnel monitoring annual reports submitted pursuant to the requirements of Technical Specification 6.9.1.5:

1. Attachment 1 - Summary of Personnel Monitoring ending

, December 31,1997.

2. Attachment 2 - Work and Job Function Exposure Tabulation - 1997 Report.

\\\

')

g*1888anang2 R

., c.-

v..vvvq 4

4 Personnel Monitoring Reports '

'W3F1'-98-0054 l

- Page 2 March 30,1998 Should you have any questions on the monitoring reports, please contact R.W. Prados at (504) 739-6632.

Very truly yours, I l<

Eh. Ewing Director Nuclear Safety & Regulatory Affairs

' ECE/RWP/ssf

- Attachments 1

(w/ Attachments) cc: E.W. Merschoff, NRC Region IV C.P. Patel, NRC-NRR I N.S. Reynolds J. Smith J.T. Wheelock (INPO Records Center)

NRC Resident inspectors Office l l

l l

l

  • b

(

.. Attachment 1 to W3Pl-98-0054 Entergy Operations, Inc.

Waterford 3~SES Killona, Louisiana 70066-License: NPF-38 (NRC)

License: Docket # 50-382

. Technical Specifications 6.9.1.5 End.of' Year Report 1997 estimated whole body number of exposure range individuals in (rems) each range no measurable exposure .......................... 1382 measurable exposure less than 0.1 ............... 692 0.1 to < 0.25 ................................. 338 0.25 to < 0.50 ..... ........................... 120 0.50 to < 0.75 ................................. 24 0.75 to < 1 ................................. 7 1 to <- 2 ................................. 5

2 to < '3 ................................. 0 3 to < 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . - O 4 to < 5 ................................. 0 5- to < 6. ................................. O  ;

6 to < 7 ................................. 0 7 to < 8 ................................. 0 8 to < 9 ................................. 0 9 to < 10 ................................. 0 10- to <.11- ................................. 0 11 to < 12 ................................. 0-12+ ................................. O Total number of personnel monitored 2568 C

<"' Attachment 2 to U3F1-98-0054 Intergy Operations, Inc.

Waterford 3 SES K111ona, Louisiana 70066 License: NPF-38 (NRC)

License: Docket # 50-382 Technical Specifications 6.9.1.5 End of Year Report 1997 Number of Personnel (>100 mrem) Total Man-Rem Station Utility Contract Station Utility Contract WORK & JOB FUNCTION Employees Em

..==================================================================ployees ===============

REACTOR OPERATIONS Maintenance Personnel 0003 0000 0016 4.079 0.276 14.099

'Oparations Personnel 0030 0001 0003 9.547 0.621 4.111 Hamith Physics Personnel 0011 0006 0018 4.223 1.123 4.386 Suparvisory Personnel 0001 0000 0000 0.602 0.003 0.077 Engineering Personnel 0000 0000 0000 1.329 0.026 0.497 ROUTINE MAINTENANCE Maintenance Personnel 0024 0003 0105 7.145 1.312 31.882 Op3rstions Personnel 0002 0000 0030 1.187 0.453 9.473 Haalth Physics Personnel 0001 0002 0002 0.175 0.245 0.581 Suparvisory Personnel 0000 0000 0000 0.196 0.000 0.020 Engineering Personnel 0000 00C0 0001 0.113 0.000 0.455 INSERVICE INSPECTION Maintenance Personnel 0000 0000 0000 0.119 0.000 0.433 Oparations Personnel 0004 0001 0002 0.647 0.272 0.447 Haslth Physics Personnel 0000 0000 0000 0.001 0.004 0.121 Suparvisory Personnel 0001 0000 0000 0.360 0.033 0.037 Engineering Personnel 0000 0000 0000 0.048 0.000 0.056 SPECIAL MAINTENANCE Maintenance Personnel 0017 0000 0025 5.638 0.004 6.438  !

Op2 rations Personnel 0003 0000 0009 0.989 0.092 2.737 Haalth Physics Personnel 0000 0001 0001 0.207 0.362 0.288 Supervisory Personnel 0005 0000 0023 1.647 0.000 9.046 Engineering Personnel 0000 0000 0015 0.132 0.000 3.921-UASTE PROCESSING Maintenance Personnel 0000 0000 0000 0.160 0.000 0.158 Oparations Personnel 0000 0000 0001 0.031 0.000 0.311 Hasith Physics Personnel 0000 0000 0000 0.077 0.001 0.052 Suparvisory Personnel 0000 0000 0000 0.002 0.000 0.000 Engineering Personnel 0000 0000 0000 0.000 0.000 0.000 REFUELING Maintenance Personnel 0011 0000 0005 5.764 0.067 3.031 Oparations Personnel 0007 0002 0014 1.983 0.606 6.043 Haalth Physics Personnel 0002 0000 0006 0.831 0.092 1.456 SupSrvisory Personnel 0002 0000 0001 0.389 0.000 0.148 Engineering Personnel 0001 0000 0006 0.378 0.001 1.059 TOTALS M11ntenance Personnel 0055 0003 0151 22.905 1.659 56.041 Op3 rations Personnel 0046 0004 0059 14.384 2.044 23.122 Hamith Physics Personnel 0014 0009 0027 5.514 1.827 6.884

-Suparvisory Personnel 0009 0000 0024 3.196 0.036 9.328 Engineering Personnel 0001 0000 0022 2.000 0.027 5.988

, GRAND TOTAL 0125 0016 0283 47.999 5.593 101.363

  • The dose assignments to the various duty functions are based on Electronic Dosimeter measurements.

I L