ML20217F406

From kanterella
Jump to navigation Jump to search
Provides Advance Notification of Second of 2 Shipments of Spent Nuclear Fuel Consisting of Quantity of SNM of Moderate Strategic Significance.Info Required by 10CFR73.72 Provided on Encl Shipment Id Form
ML20217F406
Person / Time
Site: University of Iowa
Issue date: 03/18/1998
From: Wendt S
IOWA STATE UNIV., AMES, IA
To: Bennington G
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
References
NUDOCS 9804280157
Download: ML20217F406 (4)


Text

.-

.05000//6046 aat Aro l

IOWA STKfE UNIVERSITY l"" lf%"4*"l"Li seg, e.,ieg OF SClENCE AN D TECHNOLOG Y 2025 11 M. Black Engineering Building Ames, Iowa 500 1 216o 525 294 1423 FAX 515 294-326s March 18,1998

[ R& $7 [

Gloria Bennington Spent Fuel Project Office MS 0-6 F 18 U.S. Nuclear Regulatory Commission Washington, DC 20555-0001 l

Dr. Mrs. Bennington:

l The purpose of this letter is to provide advance notification of the second of two shipments of spent nuclear fuel by Iowa State University. The information required by 10 CFR 73.72 is provided on the Shipment ID form which is enclosed. The governor's designees of the states in which the shipment will pass will be notified per 10 CFR 71.97(c) and (d).

l l

The shipment is of a quantity of SNM of moderate strategic significance However, arned escorts for the l

shipment have NOT been arranged since the unshicided dose rate from the contents of tie package does NOT exceed 100 rem per hour at 3 feet as specified in 10 CFR 73.37 (a). 'Ihe in-transit physical protection of the SNM has been arranged in accordance with the requirements of 10 CFR 73.67(e)(3). The l

enclosed route, which was approved by the NRC, will be used even though the shipment is NOT a highway route controlled quantity.

As with other recent spent fuel shipments that have passed though the state of Tennessee, the TransCom l

satellite tracking system will be used to track the progress of the shipment.

Please feel free to contact me (515) 294-0539 if you have any questions.

Sincerely, f f.

Scott E. Wendt Reactor Manager l

c: (with enclosures)

Bill Tobin, US NRC, Region Il j

\\

Jim Kameley, US NRC, Region III Lveek 9804280157 900318 PDR ADOCK 05000116 P

PDR

@v\\0S

c 050 00// 6 0 40f Shipment ID: R59-9803B 03/183 8

1. Shipper
2. Carrier l

l Scott E. Wendt Tri-State Motor Transit Co.

209W Nuclear Engr. Lab.

Joplin, MO lowa State University 208-232-3445 or Ames,IA 50011 800-641-7500 515-294-0539

3. Receiver
4. Notification David Blanchard This notification is being furnished in compliance Westinghouse Savannah River with NRC regulations in:

Savannah River Site, Bldg 105 L Aiken, SC 29808 10 CFR 73.72 803-557-6087

5. PlWSICAL DESCRIPTION Physical Form Aluminum clad plates (0.125" x 3" x 26").

Fuel matrix is UAl, Quantity 77 plates in one BMI-l cask 1.68 kg U-235 Type of Reactor UFR-10 (Argonaut type)

Original Enrichment 93 %

I

6. SHIPMENT INFORMATION
a. Mode: Highway shipment - Tractor / Trailer - Exclusive Use Vehicle
b. Transferpoints: NONE
c. Route: (NRC Approved Route.) The street address of the point of origin is:

112A Nuclear Engineering Laboratory Iowa State University Ames,IA 50011 Page 1 of 3 pages l

\\

'I 0 50 00f/ 6 0 90 Shipment ID: R59-98038 03/18/98 and the route to be used within the state ofIowa is:

Bissell Road to Union Drive.

Union Drive to Sheldon Avenue.

Sheldon Avenue to Lincoln Way.

Lincoln Way to Duff Avenue.

Duff Avenue to US-30 US-30 to I-35.

I-35 to I-80.

I-80 to I-280.

1-280 to Iowa / Illinois border.

The shipment is scheduled to be transported through (or into) the following additional states using the routes indicated:

Number State Route (s)

Scheduled Entry Time 1

Iowa US-30 to I-35 to I-80 to I-280.

Commence at 3:00 pm on 3/31/98 2

Illinois 1-280 to I-74 to I-474 to I-74 to I-55 7:00 pm to I-74 to I-57 to I-24.

on 3/31/98 3

Kentucky I-24.

3:30 am on 4/1/98 4

Tennessee I-24.

6:30 am on 4/1/98 5

Georgia I-75 to I-285 to I-20.

9:30 am on 4/1/98 6

South I-20 to SC-19.

3:P', pm Carolina on 4/1/98 Savannah Arrives at River Site 4:30 pm Page 2 of 3 pages

,o, Shipment ID: R59 9803B 03/18/98 8.

This notification is being provided by:

Organization:

Iowa State University By:

(Signature)

Address:

209W Nuci Ener Lab Reactor Manager Ames. IA 50011-2241 l

1 NRC License No.

R-59 Page 3 of 3 pages

__