.6 I

October 4, 1999 s'

1'. m L

VEMORANDUM TO: Cheryl A. Trottier, Chief

. Radiation Protection, Environmental Risk and Waste Management Branch.

Division of Risk Analysis and Applications.

Office of Nuclear Regulatory Research -

FROM:

. Elizabeth Q. Ten Eyck, Director Original signed by:

Division of Fuel Cycle Safety and Safeguards, NMSS

SUBJECT:

REVIEW OF NCRP DRAFT REPORT " URANIUM: RADIATION PROTECTION GUIDELINES"

~ Attached are comments on the above draft report. If you have any questions, please contact Sean Soong at 415-8155 of my staff.

Attachment:

As stated Distribution (FCSS Ticket 1999-117) vel:tt NRCffle" Center FUBOC" FCSS R/F FCSS T/F NMSS R/F LIB R/F LIB T/F Madams J

i

~ [G:\\ lib \\ fess99-117.wpd]

LIB LIB FCSS / FCSql, OFC-LIB //) 6 LIB ' h NAME.

SSoong:mm PSh'eaQ CEn893 TSMrrh M%er ETenEyck DATE 10h99 10/hM9 10/d /99 10/ 4/99 [0/ /99 10/&-/99 lo/Wtr/

i f

i l

of os i

vq-\\ PT90 NI g Cu.vWbtup &

N - t 77

.QOO11 9910140132 991004 PDR ORG NOMApg

j'l

[f fd*""'*%.

c{'lg' UNITED STATES

"{

j l NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20086 4001

% q,,,+

October 4, 1999 MEMORANDUM TO: Cheryl A. Trottier, Chief Radiation Protection, Environmental Risk j

and Waste Management Branch i

Division of Risk Analysis and Applications Office of Nuclear Regulatory Research

. FROM:

Elizabeth Q. Ten Eyck, Director.

Division of Fuel Cycle Safety d

and Safeguards, NMSS

SUBJECT:

REVIEW OF NCRP DRAFT REPORT " URANIUM: RADIATION PROTECTION GUIDELINES" Attached are comments on the above draft report, if you have any questions, please contact Sean Soong at 415-8155 of my staff.

Attachment:

As stated j

l

g.

.g L

'1 Comments on NCRP Draft Reoort

" Uranium: Radiation Protection Guidelines" i

Eage Llan Comments 21 5

. Equation 3.3 should be revised as follows: UF + 2H O = UO F, 2

2

+4HF-I 66 17' Inhalation, e (50) under 1 and 5 AMAD for U-235, type M should 4

4 be revised to 2.8x10 and 1.8x10, respectively. These data are listed in page 68, ICRP 68, July 1994.

68-

-10 in the Table 6.1, fraction absorbed to blood for Class Y under ICRP 30 model should be revised from 0.098 to 0.054.

'74 21 Section 7.3, " Internal Exposure Monitoring" addresses only a bioassay technique for the internal exposure monitoring We recommend that this section be expanded to include the measurement of activity concentration in air by means of an air sampler as another technique for monitoring intemal exposure.

78 10-20 This paragraph should describe how the data in Tables 7.2 and 7.3 is obtained.