T
.
j a" "i %g
UNITED STATES
f
,\\
NUCLEAR REGULATORY COMMISSION
.
$k.f f5
r 'GION IV
611 RYAN PLAZA ORIVE. SulTE 400
%
'
9.....8
'
AR LINGTON. T E XAS 76011 8064
APR 21 1998
i
l
Charles M. Dugger, Vice President
l
Operations - Waterford 3
l
Entergy Operations, Inc.
'
P.O. Box B
Killona, Louisiana 70066
SUBJECT: NRC INSPECTION REPORT 50-382/98-06 AND NOTICE OF VIOLATION
Dear Mr. Dugger:
From February 1 through March 21,1998, an inspection was conducted at your Waterford
Steam Electric Station, Unit 3 reactor facility. The enclosed report presents the scope and
I
results of that inspection.
During this inspection, three violations of NRC requirement were identified. The first violation
l
involved the failure to test a containment isolation valve (CVC-103) after performing
maintenance to ensure that the velve could still perform its intended safety function.
The second violation involved a failure to perform comprehensive corrective actions following
l
overflow of the spent fuel pool. Several other diaphragm valves with deficiencies were identified.
l
and as a result, it was determined that the scope of your staff's corrective actions was narrowly
l
focused.
The third violation involved an engineer performing an operational activity without the direction or
concurrence of control room personnel. This was a repeat of a similar violation that occurred in
early 1996.
These violations are cited in the enclosed Notice of Violation (Notice) and the circumstances
surrounding the violations are described in detailin the enclosed report. Please note that you
j
are required to respond to this letter and should follow the instructions specified in the enclosed
j
Notice when preparing your response. The NRC will use your response, in part. to determine
!
l
whether further enforcement action is necessary to ensure compliance with regulatory
l
requirements.
In accordance with 10 CFR 2.790 of the NRC's " Rules of Practice," a copy of this letter, its
enclosures, and your response will be placed in the NRC Public Document Room (PDR).
I
l
l
9804230107 980421
ADOCK 05000382
G
.
4
Entergy Operations, Inc.
-2-
Should you have any questions concerning this inspection, we will be pleased to discuss thern
with you.
S'
rel ,
/
li. Harrell, Chief
Pro, et Branch D
Divi on of Reactor Projects
Docket No.:
50-382
License No.: NPF-38
Enclosures:
2. NRC Inspection Report
50-382/98-06
cc w/ enclosures:
Executive Vice President and
Chief Operating Officer
Entergy Operations, Inc.
P.O. Box 31995
Jackson, Mississippi 39286-1995
Vice President, Operations Support
Entergy Operations, Inc.
P.O. Box 31995
Jackson, Mississippi 39286-1995
Wise, Carter, Child & Caraway
P.O. Box 651
Jackson, Mississippi 39205
General Manager, Plant Operations
Waterford 3 SES
Entergy Operations, Inc.
P.O. Box B
Killona, Louisiana 70066
I
l
1
.
i
.
Entergy Operations,. Inc.
-3-
1
Manager - Licensing Manager
Waterford 3 SES
Entergy Operations, Inc.
,.
l
P.O. Box B
l
Killona, Louisiana 70066
i
Chairman
l
Louisiana Public Service Commission
j.
One American Place, Suite 1630
'
Baton Rouge, Louisiana 70825-1697
Director, Nuclear Safety &
,
Regulatory Affairs
!
Waterford 3 SES
'
Entergy Operations, Inc.
P.O. Box B
'
Killona, Louisiana 70066
William H. Spell, Administrator
i
Louisiana Radiation Protection Division
l
P.O. Box 82135
I.
Baton Rouge, Louisiana 70884-2135
l
l-
Parish President
St. Charles Parish
l
P.O. Box 302
Hahnville, Louisiana 70057
Mr. William A. Cross
l
Bethesda Licensing Office
i
3 Metro Center
Suite 610
l
Bethesda, Maryland 20814
Winston & Strawn
1400 L Street, N.W.
l
Washington, D.C. 20005-3502
.
.
.
Entergy Operations, Inc.
-4-
APR 21 1998
E-Mail report to T. Frye (TJF)
E-Mail report to T. Hiltz (TGH)
E-Mail report to NRR Event Tracking System (IPAS)
E-Mail report to Document Control Desk (DOCDESK)
E-Mail report to Richard Correia (RPC)
E-Mail report to Frank Talbot (FXT)
bec to DCD (IE01)
bec distrib. by RIV:
Regional Administrator
Resident inspector
DRP Director
DRS-PSB
Branch Chief (DRP/D)
MIS System
Project Engineer (DRP/D)
RIV File
Branch Chief (DRP/TSS)
J
R:\\_WAT\\WTQgf= Copy with
RP.JMK
DOCUMENT NA
+
ent, indicate in bow
surd "J" = Copy with qeclosures "N" = No copy
To receive copy offort
'
su
RI$W fARB(,R ) dgNRR _
.tR
C:DRP/D
Ril: RIM,
5
DRLailyEX.t
JMK4t'onyjM M'dg6rVV
MAK W sM
PHHarrell
4/1, /98 7 / 4/M /98'\\
4/7.)ggd
4/ /98
4/f) /9{f Tng
\\
yFFICIAL RECORD COPY
\\ \\#7
'
'
i
.
l
f
Entergy Operations, Inc.
-4-
APR 21 1998
)
i
l
E-Mail report to T. Frye (TJF)
I
E-Mail report to T. Hiltz (TGH)
l
E-Mail report to NRR Event Tracking System (IPAS)
'
E-Mail report to Document Control Desk (DOCDESK)
E-Mail report to Richard Correia (RPC)
E-Mail report to Frank Talbot (FXT)
i
bec to DCD (IE01)
bec distrib. by RIV:
Regional Administrator
Resident inspector
1
DRP Director
DRS-PSB
l
Branch Chief (DRP/D)
MIS System
Project Engineer (DRP/D)
PlV File
Branch Chief (DRP/TSS)
<
L!30010
' R:\\_WAT\\WTQgf
RP.JMK
DOCUMENT NA
ent, indicate in bow
'
a Copy with
surd "E" = Copy with qeclosures "N" = No copy
To receive copy ofAop
ey
RI$W f#RN)(N)' /fNRR _ M
C:DRP/D l
Ril:RIMF,
i
DRLa'nyEfQ
JMKfet'on)(W MBg6rty/V
MAKWsJ(f ' PHHarrell
4/f) /97\\Tnf 4/R/987/ 4/t1/98'\\
4/2.U$'Md 4/ /98