Text

., .

,

1

August 29,1997

Mr. W. T. Subalusky, Jr.

Site Vice President

LaSalle County Station

' Commonwealth Edison Company

2001 North 21st Road

Marseilles, IL 61341

t

Dear Mr. Subalusky:

SUBJECT:

NRC INSPECTION REPORT NO. 50 373/97007; 50 374/97007 AND

- NOTICE OF VIOLATION

Dear Mr. Suba!usky:

This refers to the inspection conducted on May 10 through June 27,1997, at the LaSalle

f acility. The enclosed report presents the results of that inspection.

During this 7-week inspection period, your staff's performance on three occasions

demonstrated a non conservative approach to equipment operability. Specifically,

operations shif t management waited 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> to declare a residual heat removal pump

inoperable for the low pressure coolant injection mode and 24 houre for the shutdown

cooling mode, while pursuing the calibration accuracy of test instrumentation as the

possible cause of the pump's failure to meet surveillance test acceptance criteria, la

addition, operations shift management directed and operators conducted a radioactive

waste discharge without first resolving operability concerns with lake blowdown flow

Indication. Finally, post-maintenance testing to ensure operability following replacement of

all four air start motors on an emergency diesel generator did not reflect the possible effect

of the maintenance on emergency diesel generator start time.

- Based on the results of this inspection, the NRC determined that three violations of NRC

requirernents occurred. These violations are cited in the enclosed Notice of Violation

(Notice) and the circumstances surrounding them are described in detailin the subject

inspection report. Two of the violations are of concern because they involve the non-

conservative approach to equipment operability discussed above. The third violation

involves a f ailure to apply appropriate radiological markings to tygon tubing installed in the

Jplant and indicates that plant personnellack knowledge of radiological administrative

controls.

You are required to respond to this letter and should follow the instructions specified in the

enclosed Notice when preparing your response. The NRC will use your response, in part,

to determine whether further enforcement action is necessary to ensure compliance with

regulatory requirements.

9709250007 970829

PDR

ADOCK 05000373

0

-PDR

"

,

-_

_

-

,

W. T.- Subalusky, Jr.

2-

- In accordance with 10 CFR 2.790 of the NRC's " Rules of Practices," a copy of this letter,

its enclosures, and your response will be placed in the NRC Public Document Room (PDR),

Sincerely,

Orig, signed by Melvyn Leach

Melvyn N. Leach, Chief

Operator Licensing Branch

Division of Reactor Safety

- Docket Nos.: 50 373; 50-374

License Nos.: NPF-11; NPF-18

Enclosures:

1.-

Notice of Violation

2.

Inspection Report

50 373/97007; 50 374/97007

cc w/encls:

T. J. Maiman, Senior Vice President

Nuclear Operations Division

D. A. Sager, Vice President,

Generation Support

,

H. W. Keiser, Chief Nuclear

Operating Officer

F. Dacimo, Plant General Manager

P. Barnes, Regulatory Assurance

Supervisor

4

1. Johnson, Acting Nuclear

Regulatory Services Manager

Richard Hubbard

Nathan Schloss, Economist

Office of the Attorney General

State Liaison Officer

Chairman, Illinois Commerce

Commission

Document Control Desk-Licensing

DOCUMENT NAME: R:\\lNSPRPTS\\ POWERS \\LASA\\LAS97007.DRP

To ,ecewe e copy of ttwo document, traficate in the boa 'C' = Copy without attachnent/ enclosure "E' = Copy with attachmentlenclosu,e

  • N* = No

copy

OHICL

Riu

]

Rh8

[

Riu

l

Ritt

l

Hill

l

NAMt

Hes/co

Oenoway

Stua,

ihn0

Leach

Daft

09! 49 7

09/ 19 7

09/ /97

09/ 19 7

09/ s97

OFFIC AL MECORD COPY

f

.- m.

.

..

i

.

.

.

--

-.+. -c-.

- - . -

%

.

.-

.

- . , .

.~.

. _ - - . ~ .

. _ ..

. . . ,

. _ . _

._.

_ .. _ . ._

.__

-

<

w

.-

W. T. Subalusky, Jr _

-3.

,

. t

Distribution:

Docket File w/encls

DRP w/encls

PUBLIC IE-01 w/encle

Rlli PRR w/encls

,

OC/LFDCB w/encls

SRI LaSalle w/encls -

,

CAA1 w/encls (E mail);

A. B. Beach w/encls

Project Manager, NRR w/encls -

Deputy RA w/encls

RAC1 (E-Mail)

DRS (2) w/encls

Rlll Enf. Coordinator w/encls

DOCDESK (E-mail)

,

TSS w/encis-

.

$

4

. . ,

.,

.

.

,-

-

3---

-

r-

, - .

-