Text
.
~
O uuo S/JAAMENTO MUNICIPAL U11UTY DISTRICT C 62015 Street. P.o. Box 16830, Sacramento CA 368621830.(916) 462 3211 AN ELECTRIC SYSTEM SERVING THE HEART OF CALIFORNIA AGM/NUC 90-236 September 04, 1990 I
U. S. Nuclear Regulatory Commission Attn J. B. Martin, Regional Administrator Region V 1450 Maria Lane, Suite 210 Halnut Creek, CA 94596 Docket No. 50-312 Rancho Seco Nuclear Generating Station License No. OPR-54 SPENT FUEL POOL LEAKAGE ASSESSMENT
Dear Mr. Martin:
Attached for your information is our Final Engineering Report, Assessment of Spent Fuel Pool Liner Leakage.
The District has completed its investigation and all planned actions to reduce the leakage rate. He trust this report will resolve any concerns you may have on this issue.
Members of your staff with qtestions requiring additional information or clartf tcation may contact Jerry Delezenski at (209) 333-2935, extension 4914.
Sincerely, f/Yh A
.k Dan R. Keuter Assistant General Manager Nuclear Attachment cc:
C. Myers, NRC, Rancho Seco Document Control Desk, Washington DC ll,llllIll,llllLil,llI.ll i
j /
9V09190239 900904 iLE C0PY fDR ADOCK 0500 2
RANCHO SECO NUCLEAR GENERATING STATION O 1444o Twin Cities Road, Herald, CA 95638-9799;(2o9) 333 2935