Apil 16, 1998 Dr. J. Michtsl Rowa, Chisf Raictor Radittion Division Nationalinstitute of Standards and Technology U. S. Department of Commerce Gaithersburg, Maryland 20899
SUBJECT:
INITIAL EXAMINATION REPORT NO. 50-184/OL-98-01
Dear Dr. Rowe:
During the week of March 6,1998, the NRC administered initial examinations to employees of your facility who had applied for a license to operate your National Institute of Standards and Technology Reactor. The examination was conducted in accordance with NUREG-1478, "Non-Power Reactor Operator Licensing Examiner Standards," Revision 1. At the conclusion of the examination, the examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosures will be placed in the NRC Public Document Room.
Should you have any questions concerning this examination, please contact me on (301) 415-2170.
Sincerely, ORIGINAL SIGNED BY:
Seymour H. Weiss, Director Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-184
Enclosures:
1.
Initial Examination Report No. 50-184/OL-98-01 2.
Facility comments with NRC resolution 3.
Examination and answer key (RO/SRO) cc w/encis:
See next page DISTRIBUTION w/ encls.:
DISTRIBUTION w/o encls.:
)
PUBLIC PDND R/F g ()
TDragoun, RI JRoe i
\\
TMichaels, PM LTremper, LFDCB (T-9 E-10)
'D Facility File (DMcCain)
- Document Control ;
y")T PUBLIC Docket Files (50-184)
DOCUMENT NAME: G:\\NIST.INR Ta resolve e copp of this dooumont, indcote in the boa: 'C' = Copy without attachment / enclosure
'E' = Copy with a techment/ enclosure
'N' se No copy OFFICE PDND:CE,. m E
HQipB//]
E PDND:D l
l l
NAME PDoyle8'[/M Of#d::'a!n' SWeiss DATE 04F998 04 6 /98 04/ /98 OFFICIAL COPY 9804220176 900416 PDR ADOCK 05000184 V
pe utuq
- t UNITED STATES g
g NUCLEAR REGULATORY COMMISSION o
2 WASHINGTON, D.C. 20066 4 001 April 16,1998 l
l l
Dr. J. Michael Rowe, Chief Reactor Radiation Division National Institute of Standards and Technology U. S. Department of Commerce Gaithersburg, Maryland 20899
SUBJECT:
INITIAL EXAMINATION REPORT NO. 50-184/OL-98-01 i
Dear Dr. Rowe:
During the week of March 6,1998, the NRC administered initial examinations to employees of your facility who had applied for a license to operate your National Institute of Standards and Technology Reactor. The examination was conducted in accordance with NUREG-1478, "Non-Power Reactor Operator Licensing Examiner Standards," Revision 1. At the conclusion of the examination, the examination questions and preliminary findings were discussed with those members of your staff identified in the enclosed report.
In accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter and the enclosures will be placed in the NRC Public Document Room.
Should you have any questions conceming this examination, please contact me on (301) 415-2170.
Sincerely, J
Seymour 70. Weiss, Director Non-Power Reactors and Decommissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-184
Enclosures:
1.
Initial Examination Report No. 50-184/OL-98-01 2.
Facility comments with NRC resolution 3.
Examination and answer key (RO/SRO) cc w/encis:
See next page
1 4
NationalInstiture of Standards Docket No. 50-184 and Technology i
l cc:
Montgomery County Executive County Office Building Rockville, Maryland 20858 Director Department of State Planning 301 West Preston Street Baltimore, Maryland 21201 Director Department of Natural Resources Power Plant Siting Program Energy & Coastal Zone Administration Tawes State Office Building Annapolis, Maryland 21401 Mr. Tawfik Raby, Deputy Chief Reactor Radiation Division NationalInstitute of Standards and Technology U.S. Department of Commerce Gaithersburg, Maryland, 20899 Honorable Michael L. Subin Montgomery County Council Stella B. Wemer Council Office Building Rockville, Maryland 20850 l
l 1