% p asyaAORQ v

T PRELIMINARY.N0TIFICATION h,7 b/ha.

V November 8,1978 PREi.IMINARYNOTIFICATIONOFEVENTORUNUSUALOCCURRENCE--PNO-78-190 l

Th;s )reliminary notification constitutes EARLY not: ice of an event of PUSS 13LE safety or public interest significance.

The information j

presented is as initially received without verification or evaluation and is basically all that is known by IE staff on this date.

Facility: Privately Owned Landfill Norton, Massachusetts

Subject:

RADI0 ACTIVE MATERIAL IN PRIVATE DUMP On October 16, 1978, a member of the public contacted Region I and l

reported that he had detected radiation on some industrial itens in a dump area near Attleboro, Massachusetts.

i i

On October 24, 1978, Region I inspectors accompanied by representatives of the Commonwealth of Massachusetts and local governments conducted a l

preliminary survey of the dump site.

Industrial items reported by the

/l individual to be radioactive were surveyed by the inspectors and found seg to have no radiation levels above background. A more detailed survey of other sections of the dump, however, identified three areas with localized l

radiation readings of 5 to 15 millirad / hour gross beta-gamma above 1

(

background.

The radioactivity appeared to be associated with the soil l

and to extend to at least a depth cf four inches.

Soil samples were obtained and analyzed to identify the radioactive material.

Preliminary analysis by Region I and DQE's Radiological and Environmental Services Laboratory indicated that the radioactive material appeared to be natural and depleted processed uranium materials of unknown chemical composition. Analysis is continuing to identify the chemical composi-tion of the material which may indicate its source.

The dump is located on privately owned land intersected by the Norton-l Attleboro town line. All detected radioactivity was located in the l

section of the dump that is within the town of Norton. All dumping on this private land was stopped approximately six years ago as a result of local government action.

The property is not fenced, but there is a steel cable restricting entrance via the roadway.

The nearest normally occupied area is the land owners home located approximately 100 yards from the radioactive areas.

On October 31 through November 2,1978, Region I inspectors accompanied by local and Commonwealth governmental representatives conducted an extensive surface survey of the dump site and identified areas of up to a total of 50,000 square feet on the Norton side of the dump with radiation readings of between 0.5 and 2 millirad / hour gross beta-gamma gs 7 j

?.

I

_=

==

CONTINUED

,,2utd7 bEO 9804220112 781108 PDR I&E PNO-78-190 PDR

I

?

1 I

Page 2

' November 8, 1978 l

)

Continued PNO-78-190 and isolated small areas of up to 20 millirad /hr gross beta-gamma above background.

Soil. samples were obtained to a depth of about 24 inches below the surface; ground water and mud samples were also obtained.

These samples will also be analyzed to identify the radioactive material.

An investigation is being conducted to determine the source of this material.

A meeting will be held between NRC:IE-I, Town of Norton, and the Commonwealth of Massachusetts officials on November 9,1978, to inform them of findings to date, and a press release.is planned at that time.

Media interest is expected because of public concern regarding radio-active material in the public domain. The Commonwealth of Massachusetts and local governments are being kept informed.

j

Contact:

DSly, IE x28188 LHigginbotham,,'_IE.x2809 F

~~

}

1 wu,. i Distribution:

Transmitted H St G _ G O

~

A Chairman Hendrie Cotadissioner Bradford S. J. Chilk. SECY Commissioner Kennedy Commissioner Ahearne C. C. Kammerer, CA 4

Commissioner Gilinsky, (For Distribution)

Transmitted: MNBB N

\\~>

P. Bldg IVOh J. G. Davis, 14 L. V. Gossick, EDO H. R. Den;on, NRR Region T l \\ 11 (#

S. H. Hanauer, EDO R. C. DeYoung, NRR J. J. Fouchard, PA R. J. Mattson, NRR N. M. Haller, MPA V. Stello, NRR (MAIL)

R. G. Ryan, OSP R. S. Boyd, NRR J. J. Cummings, IA H. K. Shapar, ELD SS Bldg ii: 10 R. Minogue, SD l

C. V. Smith, NMSS PRELIMINARY NOTIFICATION i

l:

l l

,,__,,,m...

ave-*"***v*

e..