ML20216H459

From kanterella
Jump to navigation Jump to search
Advises That in Course of 870521 Meeting Incorrect Statement Made Re Technical Differences Between Two Plants.Seismic Ground Accelerations & Response Spectra for Each Unit Documented in FSAR Section 3.7
ML20216H459
Person / Time
Site: Sequoyah  
Issue date: 06/24/1987
From: Gridley R
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF ADMINISTRATION & RESOURCES MANAGEMENT (ARM)
References
NUDOCS 8707010408
Download: ML20216H459 (2)


Text

.

9-TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSCE 374o1 SN 157B Lookout Place JUN 241987 U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C.

20555 centlement In the Matter of

)

Docket Nos. 50-327 Tennessee Valley Authority

)

50-328 SEQUOYAH NUCLEAR PLANT - TVA-NRC MEETING OF MAY 21, 1987 In the course of the subject meeting (as documented on page 293 of the emeting transcript), when discussing the significance of Watts Bar with respect to Sequoyah restart, TVA made an incorrect statement in regard to technical differences between the two plants. TVA stated that the seismic ground accelerations for the two plants are different. The seismic ground accelerations are the same for Sequoyah and Watts Bar.

However, the response spectra are different for the two plants. As a-result, the seismic loads are greater at Watts Bar than those at Sequoyah. Designs for plant features such as pipe supports are different for the two plants. The seismic ground accelerations and response spectra for each plant are documented in section 3.7 of their respective Final Safety Analysis Reports.

This matter was discussed with J. A. Zwolinski on June 11, 1987. If you have any questions, please telephone D. L. Williams at (615) 632-7170.

Very truly yours, TENNESSEE VALLEY AUTHORITY 8707010400 870624 F

/( '

ADOCK0500g7 R. L. Gridley, Director PDR P

Nuclear Safety and Licensing ec: See page 2 0

An Equal Opportunity Employer 0

p r U.S. Regulatory Commission JUN 241987-cc: Sequoyah Resident Inspector Sequoyah Nuclear Plant 2600.Igou Ferry Road

' Soddy Daisy, Tennessee 37379 Mr. C. G. Zech, Assistant Director Regional Inspections

. Division of TVA Projects Office of Special Projects U.S. Nuclear Regulatory Commission Region II-101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. J. A. Zwolinski, Assistant Director for Projects office of Special Projects U.S. Nuclear Regulatory Commission 4350 East West Highway EWW 322 Bethesda, Maryland 20815 8

, ;