March 18,1998 Mr. William C. Whitehead, Plant Manager
-Westinghouse Electric Company Specialty Metals Plant R D #4, Box 333 Westinghouse Road Blairsville, Pennsylvania 15717-8904
SUBJECT:
NRC INSPECTION NO. 99900005/98-01 Dear Mr.Whiteheadi During the period February 18-20,1998, the U. S. Nuclear Regulatory Commission (NRC) performed an inspection of the Westinghouse Electric Corporation Specialty Metals Plant (SMP),
located in Blairsville, Pennsylvania. The enclosed report presents the results of that inspection.
The purpose of the inspection was to review the manufacturing and testing activities and determine if these activities were conducted in accordance with NRC requirements. The.
Inspectors reviewed documentation associated with the manufacture of zirconium alloy fuel clad tubing used in nuclear power reactors. Within this area, the inspection consisted of an examination of procedures and representative records, interviews with SMP personnel, and
' observations by the inspectors. The inspectors did not identify any instances where the SMP quality assurance program failed to meet NRC requirements for the areas inspected. Therefore, no response to this letter is required.
In accordance with 10 CFR Part 2.790 of the NRC's " Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC's Public Document Room.
Sincerely, Original signed by:
Suzanne C. Black, Chief Quality Assurance, Vendor Inspection, and Maintenance Branch Division of Reactor Controls and Human Factors i
Office of Nuclear Reactor Regulation Docket No.: 99900005 i
Enclosure:
Inspection Report No. 99900005/98-01 DISTRIBUTION flX i
AKe.vvhole w/o eAd.
M HOMB R.F.
Mkmr DOCUMENT NAME: G:\\Fmel\\SMP9801.4w/A Ta secohre a espy of this doeurnent, indeste in the bons "C" = Copy without enclosures "E" = Copy with enclosures 'N" = No copy HOMB 08Dr E
DE:EMCB-E SC:HOMB' 6
BC:HOMB d
0FFICE HOMB:DRCH 6-7 NAME RPettiss:ccto GCffdHna' DNaujock f/,
RAGram %
SCBlack 9$3 DATE 03/$/98f/7 03/// /98 03/// /98 03/lV98 03/l6 /98 0FFICIAL RECORD COPY:
9003200056 900318 PDR GA999 EMWEST 99900005 PDR diyk 3D
F.
March 18, 1998
' Mr. William C. Whitehead, Plant Manager
. Westinghouse Electric Company l
Specialty Metals Plant R D #4, Box 333 Westinghouse Road Blairsville, Pennsylvania 15717-8904
SUBJECT:
NRC INSPECTION NO. 99900005/98-01
Dear Mr. Whitehead:
L During the period February 18-20,1998, the U. S. Nuclear Regulatory Commission (NRC) performed an inspection of the Westinghouse Electric Corporation Specialty Metals Plant (SMP),
j located in Blairsville, Pennsylvania. The enclosed report presents the results of that inspection.
l The purpose of the inspection was to review the manufacturing and testing activities and i
determine if these activities were conducted in accordance with NRC requirements. The inspectors reviewed documentation associated with the manufacture of zirconium alloy fuel clad tubing used in nuclear power reactors. Within this area, the inspection consisted of an.
examination of procedures and representative records, interviews with SMP personnel, and
)
observations by the inspectors. The inspectors did not identify any instances where the SMP.
I i..
quality assurance program failed to meet NRC requirements for the areas inspected. Therefore, no response to this letter is required.
In accordance with 10 CFR Part 2.790 of the NRC's " Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC's Public Document Room.
Sincerely, Original signed by:
Suzanne C. Black, Chief Quality Assurance, Vendor Inspection, and Maintenance Branch Division of Reactor Controls and Human Factors Office of Nuclear Reactor Regulation l
Docket No.: 99900005.
i
Enclosure:
Inspection Report No. 99900005/98-01
)
DISTRIBUTION Central File HOMB R.F.
AHemholt Weexh
>mkm DOCUMENT NAME: G:\\ Final \\SMP9801.4FwA l
' To eseelve a espy of thle document indleste in the box: 'C" = Copy without enclosures *E" = Copy with enclosures "N" = No copy OFFICE HOMB:DRCH dP HOMByDF(DP -
E DE:EMCB E
SC:HOMB p,
BC:HOMB N
NAME-RPettiss:cct,,
GCGd&Mna" DNaujock P'4 RAGramm %
SCBlack 4 DATE-03/9 /98 V 7 03/// /98 03/// /98 03/lV98 03/l6/98 1
I l-0FFICIAL RECORD COPY:
{
l
l p*
UNITED STATES i
y j
NUCLEAR REGULATORY COMMISSION g
WASHINGTON, D.C. 20065 0001 4
o 9*****g March 18,1998 Mr. William C. Whitehead, Plant Manager l
Westinghouse Electric Company Specialty Metals Plant R D #4, Box 333 Westinghouse Road i
Blairsville, Pennsylvania 15717-8904
SUBJECT:
NRC INSPECTION NO. 99900005/98-01
Dear Mr. Whitehead:
During the period February 18-20,1998, the U. S. Nuclear Regulatory Commission (NRC) performed an inspection of the Westinghouse Electric Corporation Specialty Metals Plant (SMP),
located in Blairsville, Pennsylvania. The enclosed report presents the results of that inspection.
The purpose of the inspection was to review the manufacturing and testing activities and determine if these activities were conducted in accordance with NRC requirements. The inspectors reviewed documentation associated with the manufacture of zirconium alloy fuel clad tubing used in nuclear power reactors. Within this area, the inspection consisted of an j
examination of procedures and representative records, interviews with SMP personnel, and observations by the inspectors. The inspectors did not identify any instances where the SMP quality assurance program failed to meet NRC requirements for the areas inspected. Therefore, no response to this letter is required.
In accordance with 10 CFR Part 2.790 of the NRC's " Rules of Practice," a copy of this letter and its enclosure will be placed in the NRC's Public Document Room.
Sincerely, d%
Suzanne C. Black, Chief Quality Assurance, Vendor Inspection, and Maintenance Branch Division of Reactor Controls and Human Factors Office of Nuclear Reactor Regulation
~
Docket No.: 99900005 L
l
Enclosure:
Inspection Report No. 99900005/98-01 f
.