May 14, 1998 l

MEMORANDUM TO: Theodore R. Quay, Director Standardization Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation FROM:

Jerry N. Wilson, Senior Policy Analyst original signed by:

Standardization Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation l

DATE TIME:

May 21,1998 - 9 a.m. - Noon 10 B13 l

AND ROOM 1 p.m. - 5 p.m. 9 A18 LOCATION:

U.S. Nuclear Regulatory Commission l

One White Flint North 11555 Rockville Pike Rockville, Maryland 20852 PURPOSE:

To resolve remaining open issues on inspections, tests, analyses, and acceptance criteria for the AP600 design.

l l

PARTICIPANTS":

NRC WESTINGHOUSE T.Cheng D. Terao G. Piplica G. Thomas G. Hsii B. McIntyre J.Lyons M. Chiramal l

D. Thatcher R. Emch H. Walker M. Snodderly Docket No.52-003 l

cc: See next page

' Meetings between the NRC technical staff and applicants or licensees are open for interested members of the public, petitioners, intervenors, or other pariies to attend as observers pursuant to " Commission Policy Statement on Staff Meeting Open to the Public," 59 Federal Reaister 48344, 9/20/94. However, portions of this meeting may be closed to protect Westinghouse proprietary information. Members of the public who wish to attend should contact me at (301) 415-3145.

}Ij )

l DISTRIBUTION:

See next page DOCUMENT NAME: A:MTG0521.JNW To receive a copy of this document, indicate in the box: "C" = Copy without attachment / enclosure "E" = Copy with attachment / enclosure "N" = No copy OFFICE PM:PDST:DRPJI l D:PDST:DRPM l l

l NAME JNWilsorW J TQuay 1R4

' DATE 05/(4/94 MT 05/l 4/98

(/

OFFICIAL RECORD COPY f,

[

~'

h @ uf 9805190103 980514

3..

PDR ADOCK 05200003 E

PDR I

3

(

Westinghouse Electric Corporation Docket No.52-003 cc:

Mr. Nicholas J. Liparulo. Manager Mr. Frank A. Ross Nuclear Safety and Regulatory Analysis U.S. Department of Energy, NE-42 Nuclear and Adver,ced Technology Division Office of LWR Safety and Technology Westinghouse Electric Corporation 19901 Germantown Road P.O. Box 355 Germantown, MD 20874 Pittsburgh, PA 15230 Mr. Russ Bell Mr. B. A. McIntyre Senior Project Manager, Programs Advanced Plant Safety & Licensing Nuclear Energy Institute Westinghouse Electric Corporation 1776 I Street, NW Energy Systems Business Unit Suite 300 Box 355 Washington, DC 20006-3706 4

Pittsburgh, PA 15230 Ms. Lynn Connor Ms. Cindy L Haag Doc-Search Associates Advanced Plant Safety & Licensing Post Office Box 34 Westinghouse Electric Corporation Cabin John, MD 20818 Energy Systems Business Unit Box 355 Dr. Craig D. Sawyer, Manager Pittsburgh, PA 15230 Advanced Reactor Programs GE Nuclear Energy Mr. M. D. Beaumont 175 Curtner Avenue, MC-754 Nuclear and Advanced Technology Division San Jose, CA 95125 Westinghouse Electric Corporation One Montrose Metro Mr. Robert H. Buchholz 11921 Rockville Pike GE Nuclear Energy Suite 350 175 Curtner Avenue, MC-781 Rockville, MD 20852 San Jose, CA 95125 Mr. Sterling Franks Barton Z. Cowan, Esq.

j U.S. Department of Energy Eckert Seamans Cherin & Mellott t

NE-50 600 Grant Street 42nd Floor 19901 Germantown Road Pittsburgh, PA 15219 Germantown, MD 20874 Mr. Ed Rodwell, Manager Mr. Charles Thompson, Nuclear Engineer PWR Design Certification AP600 Certification Electric Power Research Institute NE-50 3412 Hillview Avenue 19901 Germantown Road Palo Alto, CA 94303 Germantown, MD 20874 Mr. Robert Maiers, P.E.

Pennsylvania Department of Environmental Protection Bureau of Radiation Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 i

DISTRIBUTION: Memorandum to Theodore R. Quay. Dated: May 14,1998 Docket File PUBLIC PDST R/F SCollins/FMiraglia,0-5 E7 BSheron,0-5 E7 BBoger,0-5 E7 JRoe DMatthews TJKenyon l

WCHuffman JMSebrosky JNWilson DScaletti JMoore,0-15 B18 TCheng,0-7 H15 GThomas,0-7 H15 JLyons,0-8 D1 HWalker,0-8 D1 DTerao,0-7 E23 GHsii,0-8 E23 MChiramal,0-8 H3 DThatcher,0-7 E4 REmch,0-10 D4 MSnodderly,0-8 H7 ACRS (11)

RBailey,0-2 B2 PMNS (e-mail)

OPA (e-mail)

)

i