May 8,'1998
'Mr. G. A. Kuehn, Jr.
Program Director SNEC Facility GPU Nuclear, Inc.
2574 Interstate Drive
. Harrisburg, PA 17110
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION
Dear Mr. Kuehn:
As part of the decommissioning of the Saxton Nuclear Experimental Facility (SNEF), various facility components will be shipped off site for disposal as radioactive waste. To ensure that shipments of radioactive waste meet the requirements of the regulations in 10 CFR Part 61, the staff has reviewed information on the Saxton docket related to the classification of radioactive waste. During our review, questions have arisen for which we require additional information and clarification.. Please provide responses to the enclosed request for additional information within 60 days of the date of this letter. Following receipt of the additional information, we will continue our evaluation.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely, ORIGINAL SIGNED BY:
Alexander Adams, Jr., Senior Project Manager Non-Power Reactors and D9 commissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50146
Enclosure:
As stated
! py cc w/ enclosure:
J See next page DISTRIBUTION:
E-MAIL HARD COPY Ok j
I PDoyle -
TBurdick Docket File 50-146 JRoe L
MMendonca SWeiss PUBLIC AAdams TMichaels CBassett OGC EHylton 9
SHolmes
. PIsaact DMatthews PDND r/f g
WEresian Region i TDragoun g
g GSWulNMSS/LLDP) i gf 4/
g
,A P
PDN M
NMS LLDP PDND:D a.
E ton' A
SW SWeiss 5/f/98.
5 98 5/ /98 5/1I/98 OFFICIAL RECORD COPY -
-b b.
l DOCUMENT NAME: G:\\SECY\\ ADAMS \\146RAlWA.STE
e g[ #0%,,8 1
UNITED STATES p
g j
NUCLEAR REGULATORY COMMISSION
' 4" WASHINGTON, D.C. 20&E4001 May 8, 1998 l
Mr. G. A. Kuehn, Jr.
Program Director SNEC Facility GPU Nuclear, Inc.
2574 Interstate Drive Harrisburg, PA 17110
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION
Dear Mr. Kuehn:
As part of the decommissioning of the Saxton Nuclear Experimental Facility (SNEF), various facility components will be shipped off site for disposal as radioactive waste. To ensure that shipments of radioactive waste meet the requirements of the regulations in 10 CFR Part 61, the staff has reviewed information on the Saxton docket related to the l
classification of radioactive waste. During our review, questions have arisen for which we require additionalinformation and clarification. Please provide responses to the enclosed request for additionalinformation within 60 days of the date of this letter. Following receipt of the additional information, we will continue our evaluation.
If you have any questions regarding this review, please contact me at (301) 415-1127.
Sincerely,
@+10 Alexander Adams, Jr., Sen Project Manager Non-Power Reactors and Decs. nissioning Project Directorate Division of Reactor Program Management Office of Nuclear Reactor Regulation Docket No. 50-146
Enclosure:
As stated cc w/ enclosure:
See next page l
Saxton Nuclear Docket No. 50-146 Experimental Corporation Page 1 of 2 cc:
Mr. Michael P. Murphy, Nuclear Engineer Carbon Township Supervisors Bureau of Radiation Protection ATTN: Penny Brode, Secretary Department of Environmental Protection R. D. #1, Box 222-C 13th Floor, Rachel Carson State Saxton, Pennsylvania 16678 Office Building P. O. Box 8469 Hopewell Township Supervisors Harrisburg, Pennsylvania 17105-8469 ATTN: Sally Giornesto, Secretary Mr. Jim Tydeman RR 1 Box 95 1402 Wall Street James Creek, Pennsylvania 16657-9512 l
Saxton, Pennsylvania 16678 Mr. D. Bud McIntyre, Chairman l
Mr. James H. Elder, Chairman Broad Top Township Supervisors Concerned Citizens for SNEC Safety Broad Top Municipal Building Wall Street Ext.
Defiance, Pennsylvania 16633 Saxton, Pennsylvania 16678 Mr. Don Weaver, Chairman Mr. Ernest Fuller Liberty Township Supervisors R.D.#1 R.D.#1 Six Mile Run, Pennsylvania 16679 Saxton, Pennsylvania 16678 Saxton Borough Council U.S. Army Corps of Engineers l
ATTN: Peggy Whited, Secretary Baltimore District I
9th and Spring Streets ATTN: S. Snarski/P. Juhle Saxton, Pennsylvania 16678 P. O. Box 1715 l
Baltimore, Maryland 21203 Ms. Norma ickes, Chair Bedford County Commissioners The Honorable Robert C. Jubeliter County Court House President Pro-Temp Senate of l
203 South Juliana Street Pennsylvania l
Bedford, Pennsylvania 15522 30th District State Capitol Mr. Larry Sather, Chairman Harrisburg, Pennsylvania 17120 Huntingdon County Commissioners County Court House Mr. William G. Heysek Huntingdon, Pennsylvania 16652 Licensing Department TMI Nuclear Station Saxton Community Library P. O. Box 480 Front Street Middletown, Pennsylvania 17057
' Saxton,' Pennsylvania 16678 Mr. Manuel Delgado Mr. Arthur Rone 2799 Battlefield Road Vice President Nuclear Fishers Hill, Virginia 22626 Safety and Technical Services GPU Nuclear Inc.
Mr. Eric Blocher
-.1 Upper Pond Road 216 Logan Avenue Parsippany, New Jersey 07054 Wyomissing, Pennsylvania 19610 l
r a
i Saxton Nuclear Docket No. 50-146 Experimental Corporation Page 2 of 2 cc:
i l
1 Ernest L. Blake, Jr., Esquire Shaw, Pittman, Potts, and Trowbridge 2300 N Street, NW Washington, DC 20037 l
' Mr. David Sokolsky
_4241 Liberty Bell Ct.
Eureka, California 95503 Mr. Gene Baker 501 16th Street Saxton, Pennsylvania 16678 Mr. Dick Spargo 1004 Main Street Saxton, Pennsylvania 16678 Mr. Tom Strn.d TLG Services :
148 New Milford Road East Bridgewater, Connecticut 06752 Mr. Gareth McGrath Altoona Mirror 301 Cayuga Avenue Altoona, Pennsylvania 16603 l-i l
l t
h RE*aUEST FOR ADDITIONAL INFORMATION SAXTON NUCLEAR EXPERIMENTAL FACILITY i
DOCKET NO. 50-146 General Comment 1)
Can SNEC confirm that the lower core guide blocks (guide blocks) in the reactor vessel are the only Greater Than Class C (GTCC) waste? Explain. (See questions 3 and 4 below.)
l Specific Comments
{
Comments based on the "Saxton Facility Reactor Vessel, Internals, Ex-Vessel Lead, Structural Steel and Reactor Compartment Concrete Shield Wall Radionuclide Inventory" dated December 1995 2)
Section 3 - The neutron activation analyses assumed various fuel configurations to reflect the use of uranium oxide and mixed oxide fuels. Are these simplifying assumptions conservative in terms of overestimating the concentrations of nuclides l
important for waste classification?
3)
Section 7.3.1 - This report stated that the guide blocks are GTCC waste if classified individually, but because the guide blocks are permanently bolted to the lower core plate (plate), the guide blocks and the plate can be blended, and that the blend of guide blocks and the plate is within the Class C waste limits. Provide a l
clear picture or diagram that illustrates the bolted connection between the lower core guide blocks and the lower core plate.
Comments based on the "SNEC Site Characterization Report" dated 1996 4)
Section 4.2.10 - Justify blending the pipe sections that are individually GTCC with other piping systems. Guidance for averaging concentrations in homogeneous l
waste types is presented in Section 3.1 of the " Branch Technical Position on Concentration Averaging and Encapsulation," January 17,1995.
5)
Table 4 Identify the waste class of the items listed as "To Be Detcrmined" (TBD) if these items have been evaluated and classed.
ENCLOSURE
!