KANSAS GAS AND ELECTRIC COMPANY THE ELECTRC COMPANY November 5, 1986 W4E PAES8 DENT - NUCLEAR Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D.C.

20555 KMLNRC 86-203 Re:

Docket No. STN 50-482 Subj:

License Condition 2.C.(7), Attachment 3, Item (1)

Functional and Task Analysis Ref:

1) Letter SLNRC 85-11 dated 04/01/85 from NAPetrick, SNUPPS, to HRDenton, NRC
2) Letter KMLNRC 85-245 dated 11/04/85 from GLKoester, KG&E, to HRDenton, NRC

Dear Mr. Denton:

The purpose of this letter is to fulfill the requirements of Wolf Creek Generating Station (WCGS) License Condition 2.C.(7), Attachment 3, Item (1) regarding the Functional and Task Analysis. This license condition requires Kansas Gas and Electric Company to submit ".

a description of the process used to complete the functional and task analysis, including a description and justification for all information and control deviations from the Westinghouse Owners Group Emergency Response Guidelines, Revision 1."

Reference 1, in conjunction with the suh ittal of Reference 2 as amended below, satisfies this license condition.

The three changes to Reference 2 listed below have been previously discussed with the Staff.

1.

Item 3 on page 8 of the enclosure to Reference 2 reads:

" DESCRIPTION The option to use the procedure without RVLIS was added to ten (10) EMG's.

The affected procedures are listed below.

Each procedure was mcdified to allow the reactor operator to perform the procedure step with or without RVLIS."

The description of Item 3 should ~oe clarified as follows:

" DESCRIPTION The use of the procedure without RVLIS was added to ten (10) EMG's.

The affected procedures are listed below Each procedure was modified to provide guidance for the operator to perform the procedure stop with or without RVLIS."

\\

0 0

8611100178 861105 DR ADOCK 050006 ygg, PDR I

I 201 N. Market - Wichita, Kansas - Mail Address: PO. Box 208 I Nchita, Kansas 67201 - Telephone: Area Code (316) 261-6451

a a

Mr. H. R. Denton November 5,1986 KMLNRC 86-203 Page 2 2.

Item 5 on rsge 9 of the enclosure to Reference 2 reads:

" DESCRIPTION A foldout in the generic guidelines which addressed RWST switchover criteria has been deleted in BMG ES-13, Transfer to Cold Leg Recirculation Pollowing Loss of Reactor Coolant.

JUSTIFICATION The foldout was deleted to avoid confusion since RWST switchover to cold leg recirculation must occur prior.

to initiating hot leg recirculation."

Item 5 should be revised to read:

" DESCRIPTION Step 5 of the ERG E-1 series foldout which addres+ed RWST switchover criteria has been deleted in EMG ES-13, Transfer to Hot Leg Recirculation.

JUSTIFICATION Step 5 of the foldout was. deleted to avoid confusion since RWST switchover to cold leg recirculation must occur prior to initiating hot leg recirculation."

3 Item 8 on page 11 of the enclosure to Reference 2 reads:

" This item is discussed in the response to Request 3 under Pinding 1."

Item 8 should be revised to read:

" Thio item is discussed in the response to Request 1 -under Pinding 1."

If there are any questions concerning this submittal, please contact me or Mr. O. L. Maynard of my staff.

Very truly yours, Glenn L. Koester Viue President - Nuclear GLK:see

.co : P0'Connor (2)

JCummins l

\\

STATE OF KANSAS )) ss CITY OF WICHITA )

s Glenn L.

Koester, of lawful age, being first duly sworn upon oath Officer of Kansas says that he is Vice President - Nuclear and an Gas and Electric Company; that he has read the foregoing document and knows the content thereof; that he has executed that same for of said Company with full power and authority to do behalf and on to the and that the facts therein stated are true and correct so; best of his knowledge, information and belief.

Glenn L. Koester 8

'M #

N.

Vice President - Nuclear SUBSCRIBED and sworn to before me this I day of

,F1986.