.,,y, Q w.

NEWJERSEY DEPARTMENT OF ENVIRONMENTAL PRTJTECTIOPP

~

DIVISION CF r*ATER RESOURCES sNp.

MONITORING REPORT - IRANSMITTAL SHEET'_ '

-' ' ~ ~-

.. ht chm'd.' sssoas Na,,,,

~

MsPOR m ePem00

~._

'S-

.;yQMi- ; y 1019l8 6l THRul019l816l

}

fdO6161212-l--

1

~

~^

.Public Service Electric & Gas Co P.O. Box E 7...

._._ m Hancocks Bridge, RT 08038 a% Shtim PACILITY:

Name Address Hancocks Bridge (Countv)

Salen T w (609 ) 935-6000 POftAAS ATTACHED (AudiesregofEach)

OPERATING EXC8dIONS YE8 88 0 i

' SLUOGE REPORTS. SANITARY i

O O

l l

T VWX 007 T VWX 000 T VWX 000 DYE TasTINa TEMPORARY SYPASSING O

O SLuoOE REPOR13. INDUSTRIAL DISINPECTION INTERRUPTION O

C T.VWX 010A T VWX 0108 MONITORING MALPUNCTIONs O

O A

UNITS OUT OF CPERATION O

O

{

T.VWX 011 l

T VWX 012 T.VWX 013 oTHER O

O O OJ O G-GROUNDWATER REPORTS (Desnilany "Yes**oa rentse side l

VWX 015(A,B)

VWX 016 VWX 017 NPOES 018 CHARGE MONITORING REPORT 4 VOTE N "Neurs Atrended at Pisat"on ik mwrse of #4fs hmustsise CM y

lX EPA FORM 33201 m <t AUTHENTICATION I certify under penalty of law that I have personally examined and am familiar with the information submitted in this document and all attachments and that, based on my inquiry m a.a:

of those individuals immediately responsible for obtaining the information, I believe the submitted information is true, accurate and complete. I am aware that there are significant penalties for submitting falso information including the possibility of fine and imprisonment.

LICENSED OPERATOR PRINCIPAL EXECUTIVE OFFICER or DULY AUTHORIZED REPRESENTATIVE NGbO Neme (Printed)

Neme (Printed)

S-3 S-5235 Rad. Prot./Chen. Mgr.

Grade & Registry N Tide (PrinW)

M

'C

~

W re Signamne u

y \\

s j'

  1. o 10/24/86 10/24/86 Does o.ga
  • - opgRATING EXCEPTIONSOETAILEF,.

-s 4..

_s, 1.-

l. :S/lTJS*Etr[5[isbhiMCr 6000 gallons of pEl 5.5-

..-x p M w :...-r

'2. : 9/23 Md5ppass oF 48C, 3000 gallons of pH 6.0

3. ' 5/28 ' ' 5hpass oE 4'8C, 300'g'allons of pH 10.0 '

48C discharge to 484 & 485 @ 660 6pn caused effluent pH of 10.0 4.

9/24 fran 1100 to 1330.

5.

482, 484, 485, no total residual chlorine samples were obtained 9/1 - 9/11.

Sampling systems were inocerable for the noted period.

.x HOURS ATTENDED AT PLANT Month Year I !

Day of Month 1

2 3

4 5

6 7

8 9

10 11 12 13 14 15 16 Licensed Operator 7 8 [ f f

7 7 f f 8 8 7 othen 3

4 6 3 6 6 & 6 6 6 6

Day of Month 17 18 19 20 21 22 23 24 25 26 27 28 29 20 31 Licensed Operator f f f 7 7 7 7 7 7 7 otnen

& s~ 3 s~ s' 3 S 2 3

to O

Gonarc AnacJer - Env. Affnirs

o. s t, op.se, g

ammens_PS E t,G NJ000562 I_ _ 481 PO BOX 570 10C esau 7 mum sa lo..c a..

_ _ _31 a w a r k _.nIJ. _f1210 L_ _ --- - -

neoNITORING PEA 800 Salen Generating Station m

g g ower Alloways Creek eno" 86 09 01 86 09 30 iam i:2.m usari os m os-Jen us s,,

se0TE: messe insenseelsee hosess sempinalme mis ensus.

N o card o=#,e evanvety on s.omosme as card o=a,3 evaa. sty on cosecsa TaaTeoes ramaaestsa W 3Jn asedia pods) te6JJs pedA) g

'a*m**a ",*"C 'g ga sve e S8J78 avsmass acaEIM UI4 utstTS telpelaeugt aWEAmeg spastetutt ugegfe 7g,,

00400 1

  • ^="8 1/7 GR 4

"*^**** *"'

7.40 8.00 0

pH Effluent Gross 6.00 9,00 su e

17 7 og gj 7 GR C0400 2

eaa ei.s as**u==*av 7.30 7.80 l pH maeuseassemy SU y7 GR l

Influent esanast e

50050 1

  • ^

8 CALC NA

= =^*u"a's'= sa' 315.20 532.80 l

pgo, CONT NA Effluent Gross

_T ggg 1/30 GR 00340 1

saaects

"*^*u"*"*a' 62.00 62.00 5

CO3 1/30 GR l

Effluent Gross esaasar

.MG/L aseuenessass?

J 166.00 160.00 1/30 GR 00340 2

. mei.s COD 1/30 GR Influent poseest MG/L l

neousnessemy I/30 GR 00340 4

..,,. s 0.00 0.00 0

COD 1/30 GR Effluent Net reasser 50.00 gg/g noeuseassent 50060 1

,,,.,am.W..,

NOIE NOIE NOIE MG/L u

Chlorine, Total 1

Residual, SWS esamer 0.20 Period, GR ameuse m eaf Effluent Gross vsospesoses eaya mannemvi.s emincicaa. smacuviva oerican.gsage,,u,,,n,a,=, apa6;o,r 6gg y,,,,36 ggo a

0,e,a.st aseu,,sB,T,,,,o.eeO.68,,maa,,ws,o,uat h..am,,sE,O,4.,gt,

f

  • f of,

m aarm.m.m. g,OR

.e J.

Trejo om,,r a,us, acc., usa.n s. a,s.o, co.me.rs.ti,s,,c, a,os.a.m.am,a,o,,,,,,

.o nas

=, as aaie.s,as cu a"'

609 339-4399 86 10 24 e

God. Prot./Chea Mgr.

o

. r os n =,

c

>>osce.

,o,.

a m..

osc eiao.

-,o

,,g,,,g.,,,,,,,,,,ean.4 sscutiva

.. ee.

s.., s

^88*

    • d"'***********'***'"**8ad2L:*8***84***8*******

orFaCam on aufesoAIBs0 aessef goussega ygag gag

,e TVPGS oe essesTSO N aseS NTeces or apey veobaTie & 42eisseere as es meaneans Ases)

Diccharge 481 is $11 condenser cooling water NOIE: No sanples obtained due to equipnent configuration.

PAGE OF

.. n. - v.sa.:eas. is.ysteesvious sesTsom to es useo easei. aces sea pones T.4e wasca may asor as vess s

O_-

.. ~

Fereaum fee wftarm d80m*' 8 DISCH ARGa k etTORING REPORT (DNA)

,,gM sans _ _ _._@_:_ _ER._._.

.Dy_. _ M_._ _ _ __ _ __ __ _ __

ti.u,

tsr.se' Emphus 22M8 r_penges_ PSEE.G

!U0005622 481 P.O. BOX 570 10C

's""" """***

'ac"^***'****'

__ _ _ _ _tgN3R_K_ _ _ _ _.1U__ __pl}.Q.l_ _ _ _ _ _. - -

sooNiron No ranson r.s.stu_ __SMJiM__Gl2ggTJN9 E_IAT. I(tt _ _ _ _ _ _ _

.O y

i.esariess.__I_I_H.E_R_ NJfHB' 3..@E[E__,_ _ _ _ _ _ _

86 09 01 86 09 30

/

ese m oi-m ei#m osm imm < min) mote: need hemussens eindese sesosomes aos sese6 (i fe,d 0-dy )

Qu ANTITY On LOADING (d (e,d Omfy)

OuALITY On CO88CENTRAT4000 S*E,M

,AR AISETgg

( C J)

(3448)

E WJ)

( M J)

(jedl) 88 0 -

op T 8 E"

ansattese N III AvsmAGE M ARIMuM uMITs esIMIIsuM AvtAA.E MAmsesues WestTS gg g

,g, 00530 1

maa. a

. unsus=v 52.00 52.00 ij3o ca sonrog,.gggg ggjn

~ +

SUSPCKED e.nm.e.r.,,

p V30 GR

==eu"a7===v 50.25 50.25 MG/L 1/30 GR DG, SUSPENDCD

  • emeent neeuinament 1/30 GR j

INFfNC u situ"n7sEs=T 1.75 1.75 Mg/n 0

1/30 Gn g

noe'u" UTent 30.00 45.00 **

1/30 GR 1

ICP 00551 1

,,,,t.

me..uammaar

<0.50

<0.50 1/30 Ga PL=Igninn Itm MG/L EHUDTP GROSS neeviamessiv 1/30 GR

<0.50

<0.50 1/30 GR 00551 B

.,f ^o",7f,,,

PL*PBninM lt'DROCAlmCN MG/L INI'liOTP

,,,,eam,gewe p

1/30 GR 0.00 0.00 0

urflu"n7u' ant gg m ggjL 1/30 GR 10.00' 3/h EFaDETF FEP ne venem'ent penus GR 1

<0.01 0.02 0

l 50060 1

me.s.ameLa Period GR OIIfflINC, 'IUIAL E/L uns===v

_l RESIDUE,CWS pene'"

0*20

      • u'a***"?

PERIOD GR EFFf N GROSS sa

= a ma

    • a=o=

aa==* *

    • 's, won.

.a,e o's osenea'teOs's.mastosa fe t ytusseTTED seEEE8ea#dD GA.SD u or

..mros

..ci,As.==scutivs Orricea

+ c = ='as ',am~en sa=m =use=ee To'et aseD a T

o escoveDuat t mem a rm one est suQuenv of TesO&E J. Tre o o.6='veta'6ac'cusans a D ca tsis e a= amaas v=v v.was aar 'se

/.d4/'

a-

    • =* o==a ma '=== *** au=="so = = a Radiation Prot./Chan. Mgr.

'.=.a.c a,Ou.s.,ya,5.'.o.= a.su==".* o

'.a',uu "a.."=uam" "ico'.ua *

,,,,,,,,e,,g enscutive 609 339-4399 S6 10 24 o

'c n

~....e,

..,a,.,a,

.e..,a.,sc.,es a'

== *

.D

.a

,u s c s.

^

..a u

.,,.. on aur + so assar

_=""

1-vsaa ese

,,,,,o, COeses28eV AND E= PLAN ATBOM OF AN, WBOLATIOede l*eference edJ masas emme.as he,e)

    • 7 day average j

Gonora snager - Env. Affairs i.m.

(87-8's

.g g g

PSE5G NJOOOS624 482 eassess esam.T nume..

...C..

.,,_., P O.B O_X _b.7 0_10 C

,,..,M g.W a r k,,,1(1.fil l M. _ _ _ _ _ -

adONITORING PER800 salen Generating Station

.m

,g over Alloways creek ra "

86 09 01 86 09 30 amis e an 23 aussi s u m eJoas, e n ss, se0TE: asesi lesensasione Innesso sempeestas mis ensuL (J rard Oel,)

GuaseTITY Oa LOAsapee to rard Oet) eUAbaTY On CO8eCs86TmAT80se e

s (es-JJ) 43448)

(Jedj)

(46 JJ)

(j648) ase.

==

.eAAA80sTea

,,,,, }

paJ78 avsares m as su uas unsTe winnaeues Avsmass mAmusues vessve g

g, 00400 1

= aa.u"na'me=T 7.30 7,70 0

1/7 GR

    • P8 pH 1/7 GR 6.00 9.00 SU Effluent Gross esame u saavaa'ms"7 7.30 7.80 1/7 GR C0400 2

same s pH 1/7 GR Influent esaass7 e

e SU meewsmaansast

~.

CALC "A

50050 1

e== n s 326.70 532.80 u sa.uasu s= T Flow CONT NA Effluent Gross esam T e

e e

e e

MGD 00340 1

sansets 160.00 160.00 1/30 GR usaeumsus=T CO3 MG/L 1/30 GR Effluent Gross esam T noeuseasseest GR

~

1/30 00340 2

eaupts 110.00 110.00

.saeumsus=T COD 1/30 GR MG/L Influent esamsT e

aseeveneassm?

GR 50.00 50.00 0

1/30

.,.u"n'sasan, COD 1/30 ga Effluent Net esassiv e

50.00 gg/n neewseessent 50060 1

e = = et s NOTE NOTE MOTE-usieumsma=Y MG/L

., )

I Chlorine, Total 1

esaasY 0.20 M iod GR Resia nl SE Effluent Gross Tsa.= :rs oAvs

+4*ag '.,,.*a.o*a, a g',,o,r 'g'.,g',

=*,,,ay,,,,,s = g

,TTus

.ncicas.anscuYeva Occecsa o

. - on.... -.,o.

so.

.f Dg

.,,.o,

. oo

..,o,.

o...

m., u s,,o.5,mg.,es.,e,.AE,,,,

,,,o no

,,o,,

,, uo J.

Trejo o.,

.C Cum. a

..o,, sed,, Come*L S,,.

s

,s, au har, o.e.,

,,cioo,,,c, 609 339-4399 86 10 24 mus

.h, 4.,

Rad. Prot./Chea Mgr.

n o 6 c

.,..o.,.e.=,

,sc..ao.

a

,,,,,g,,,,,,,,,,,,4,,,, coy,,,

=

6 o

.n. o e.

o6

    • 8""*******'#'8*'**"**d""*****8********d6******

OrFICan On AUTDeOntasO A4sNT m-Deutessa TsAS 38 0 O.

TvesS On en4MTs0 Sm? AmeG SEeLASSAYSOSS Or apeV V'* ^TSOceS (sejereers asal es.im'~s here)

Diccharge 402 is 312 condenser cooling water NOIE: No arrples obbined due to equipnent configuration.

ensebacas sea POmm T.4e woescu asAT seOT es vess.:

3 IO PAGE

.. vais eewsous sonT Cee 70 es umso

penasarves asAasst,d.se esat3 de otSCH AnG3 ed TONING REPORT (Dat;)

t(

W NAT BoM AL,oLLUT Ase t

$ames gLeasleeAttoes Cverem g*'pOH)

Farasist Jisa=r#Lasaame am8

,g g mean

_ _ % A._- D % _ N T_._ _ _ _ _ _ _ _ _

<I nu

<

  • I-s * >

.u.,rasse Weenn_ee_ _PSEtG_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

m 0005622 482 l_ _ _ _ ___o_. _DO_X_ _57_0 _1_0C___ _ _ _ _ _ _ _ _ _

p

      • """u"***
        • =****aa**=

_ _ __ _ _.I@EL _K _

IU__.9119.l_ _ _ _ - - - -

R wow Tonino Paneoo g

gm;n,ur_ _SNLM_gggTINg_1T1LTigtL _ _ _ _ _ _ _

v..

.o I,auvJast__JDELNJON1 QUES __ _ _ _ _ _ - __

86 09 01 86 09 30 areni in.m iu m in m.is ni imm seoit: nomes seassusesses mesess eseossehe else sena.

i is c,4 o=,e cuamverv on i.omosme se (,e o.ers ouatav, on concs.svaavions i

< *- m

sms, e ms, in-ss a
nu4s, ao. * * * *. ", * " * 'eAm,*Le 17 6 aamatve.e 4 8I-III

,y S II AG E M ARIM use UMere MIN 808utS AVE =ASE 80 AE140 UGs U98819 g

g g pg,

'00530 1

e.e 55.25 55.25 1/30 GR

"*^*""*"*"'

SOLIDS, ME ngjn SUSPE'OED meeve.me.r pen 1/30 GR ant m gq 00530 B

....t.

69.00 69.00' E/L 1/30 GR

"*^****"*"'

pig 'IUrn SUSPCOED commer a**** **"*at v30 2

Iurriswr 00530 4

"*^****"*"'

0.00 0.00 0

1/30 GR yajn SOI. IDS, 'IUTE l

SUSPDJnF'D 30.00 45.00 **

V30 Gn DTrisWP NCF 00551 1

maa.,,,,

'<0.50

<0.50 1/30 GR

. unamany PC11anrnM tr.ms HG/L GTIHNr GROSS a ovi...,

.=v 1/30 Gn

<0.50

<0.50 1/30 GR i

  • ^

00551 B

,,,,,,",",.=v MG/L PEI1aninM ICDDOCARDON N 'T

.so"u " dis =v 1/30 GR 00551 4

...,t e 0.00 0.00 0

1/30 GR mm gjn usasunamany EETImfr E meeven"ee" sear

,en 10*00 1/30 GR 0

NOTE GR 50060 1

    • =ets

<0.01 0.05 MG/L usa.uasusar CIIIRItE, 'IUEAL 1

RESIDUE, CWS 0.20 PERIOD GR

  • **" ' a s===v GROSS tats,soossa oaea maassfuntos caseecseat suscursWs orrecen eyaw'u=osaays,ve or tgs,.j gag suggo oss e.T es.Qu.sv Of 1.eObg.evaou.(S.nsh.E Ob.WE L T GG brop.SaSL S f odt J. Trejo

='e'='a*=6ac'cun.is o 'ca n's ee= t e. d'.d..as v'.*"' a s~me a=a

/

a ~ oa= =

sua o

us ar 6.c.

Radir. tion Prot./Qan. Mgr.

~' < *a'..a.a.=. 'o*,*. * =...su===". ~.o

  • .=..sau'a*=== 's cm

.ao.uai-o

,,,,g,,,, o,,,, c,4.0 suscutiv.

609 339-4399 86 10 24 a

.o 6

a.. o o.o o..

-. ~. - - -.,

or,.c.a on Aurwaaisse Aesav

u===

veaa no se

..,. a..u

""="

uc ii w...

na.. ~.

,,,,o,,,,,,,,,,

Lossestaat AssO EMPLAMAvices oF ANY WBoLAvloose 4* sine.we af.es 4.naars hera p to.rE:

No chlor,ine, total residual samples were obtained 9/1 - 9/11, 9/12 - 9/30 samples were 1/ period.

s a m.,

,,a,- a n o 1r tr 1 &

Go no ro!'

nager - Env. Affairs

.t s+.

(n r.s e, L

g PSET.G NJOOOS621

[_

483 ammes

~

PO BOX 570 10C esamit numosa l

.c a es.. si

__ _ _m a w e r k _LL _Q 21 al_ ----- - -- - - -

neonsTonino esanoo Solem Generating Station m

y,,,

g,g ewer Alloways Creek ea""

86 09 01 86 09 30 esa u s in no si+ns e m m sis-Jo s e m.u, se0TE: meed assensseless tesess sempleatas uds 8ssum.

,A.A 4.s.u i om>

a n-es, i.e.u s

o. ass g '.*.**.",,.*.a

sage;= l p ces ons,s cuawisiv om s.Onoame se cod oasts evaLerv On ConCsavnavsoas (A8JFs avsmass mansu um unive naiminum Avanaea mAmissues umsve 00400 1

  • *= h8 7.30 7.90 o

1/ 7 GR nasaeumansar PH 6.00 9.00 SU 1/7 GR Effluont Gross peau 37 7 U"

00400 2

samei s

"'^****"*"'

7.30 7.80

_l pH Influont psmee st e

e 77 GR

,e SU maeuseesssast CALC NA 50050 1

,, e,.,=g,,,,

304.50 532.80 Flow Effluent Gross cammer CONT NA MGD maeuseensansv w

1/30 GR 00340 1

s,a,mp,,a 48.00 48.00 CO3 1/30 GR Effluent Gross penmov e

e MG/L m ae useamesesv 1/30 GR 00340 2

sameta as**uasuaa' 80.00 80.00 Con

, 'l 1730 GR Influent poemer MG/L nee uengem s. w, r

]

C0340 4

.. ms >

1/30 og

"'^*""*"*"'

0.00 0.00 0

cod 1/30 GR Effluent Net psaasst 50.00 goft eseweemmess?

50060 1

... n.

"*""'"'a' NME NNE M

Chlorine, Total MG/L 1

R:3idual, SWS

.1 0.20 Period GR ameuseensar Effluent Gross

~

vggspeeONS 3 Avg estomasataD.ee e aws re tv sam.assego v s.a.

asaangO37L3 peepectPak EmSCurawE OFF8Cga

, ca.sev us. Dam. pensasyv or tae

. serf go asap aMo

.ameso ava.t,seg.gde aseD ent.e f.et o. a,e f aana.a.= =

,o,,,n eewo. ate, ma m p.

.a.s.,,,o. ar..o ro a som a.,.n., a.c co.... o.s o.a,,

ua.

J.

Trejo ns s a ar Ds.

/

o aio.

.,,c.a

,,,c.

a, o ca t.ne Cad. Prot./Chea Mgr.

..,o..,..

as. a m.

c,os.as.

,,g,,g, g,,,,,c,,ft susCurivs on 339-4399 86 10 24 6x_,09, o

.ao.

.o n

.c e. 3.. o,.

o = ~,

g s., sm e

.* a.= * * ** mpe.e.a*=r*8 ad **8=**

  • 8 *=*** * **d S ***'s
  • OFFeCem 04 AufMOABESO AeSMT toutsOsA ygAg agg on, vVPs3 04 PaINTSD

-mmaanm=*v Aase EXpbastAvtoes 08' apey wsOLATIOce8 48efe**ere e.af m shaneess heae) i Diccharge 483 is 313 condenser cooling water NME: No sanples were obhined due to equipment configuration.

PAGE OF

=..... =, a.

,,,..c

..o =0, e, u.so n

[

emesseTTsa osaas h c saarh.de haf soseas.,oLLuTANT SAngg CL64880G?T8000 CV. Tate (r70&J) y3 Fasemp m anna /4.msa ene' 8 Def CH AnG3.

TOnIN3 C'IPORT (DW".;t

, go, g i inaus

_ _@.: d_ _~~ _EF,. p_._ _ _ _ _ _ _ _ _

is n.

e nr.se' pnes 2 2M8 ameatme_ _PSE_&iG_ _.,_

!U0005622 483

__P_.O_. _BO_X_ 5.7._0 _1_0C __ _ _ _ _ _ _ _ _ _

    • ""iT =uuss=

o..c......

l @ E L.K _ _ _ M. _.92}D.l- - _ - - - - -

R.

wonironino Pensoo unq;n,ur__fiME.M_ QEgTJND 1TATION__ ___

vs..

-O o.,

v.A.

.O neu'm=1_ JO@_.NdGE0@ GEN @ __ _ _ _ -.---_

'"*N 86 09 01 86 09 30 eieni en.m w n, os m us.ie, ps:,

NOTE: Reed Insensesione Instese semipiseng this issue.

(J C's d O.dy p Qu a se Ti t y On LO. DING 44 (erd De#F)

Ou.LITY 04 COceCsecTR Af aOst

,AAAMSTs3 M 39) g )4 el 3 (A443)

(46-J J )

(jd4J) g,"

(M-M8 avanAGE M AE4M uM uMIT.

Re tNitoute AVEAAGE M AElt00M 4M68?S gg g

gg, 00530 1

58.00 58.00 1/30 GR SOLIDS, WE MG/L SUSPEOED nm T i

aseuiasmasar 1/30 GR N GROSS 00530 B

...,L a 54.00 54.00 E/L 1/30 GR J

"*^*uasus=7 snr.Tm, ME SUSPCOED essun 1/30 GR newENT 00530 4

"na

.n.

uasus=T 4.00 4.00 ggjn 0

1/30 cn SOLIDS, 'IUPE SUSPENrrn

      • via*=8"'

30.00 45.00 **

1/30 GR c','rmfr ter 00551 1

,,,,L,

=a.unsus"'

<0.50

<0.50 1/30 Ca PLIgninM IPlDROCARDONS MG/L EFFwENT GRNS a**wia*=*av 1/30 GR 00551 B

    • =n*

=sa.uas===T

<0.50

<0.50 1/30 GR l

PE:IgnrnM If1DROCARDON MG/L hN "U Y.'Es=7 1/30 CR f

00551 4

me.una 0.00 0.00 0

1/30 ca _

PE"rgninM N gjn

.unnusuf EETIIEff NE:P 10.00 neeu.n.e.s.s?

pe.

. ant 1/30 Gr.

l

~

1 50060 1

us ns 0.02 0.14 0

Period GR t

i

.unaus=Y g

1 RESIDUM.,

W

.n 0.20 PERIOD GR EFF11Efr GROSS e s.as.eoso 9 _A ** E TELEP900008 e temsse u.soe as.s t y or t.w e e we Manom. tty esAa98/T4TLE enteeCs,AL EEsCUTIVE OFFICEA so s s eeen n re.v.s sees sesomma. fee.1 so. tan veeoss sess.woou.Teoss tunsaff50 estasse am 65 a.asta.rgt v metroposants som p

one est eaQuemy or J. Tre N

<='..u*.a..c'c o....~ <=~.o 'c =ae.,='*.

'..a. =..e.r,'<a o a m a a an

= ** -

Su=="

w==

s.o Radiation Prot./Qusn. Mgr.

      • < ='.**.a.=. 'o*,*. r.<.=*.o===.~.r.' a.o ' *. S8
a. ' ~.. u s c i. ao'us='.'.c,,,,,M<,,,,,,me,,A#sa.CuTivs n

ma ar 609 339-4399 86 10 24 d

d, s..,

.o n oso i...

  • '"8"""*****"***Pa***""***d*******8"""'"****d*******

OPPICan OA AuYW!I.O ASSNT M

Deuteten vgAA 8AO DAY TV,$D Ost casNTs0 C;OestBEssT AMO EE,LAMATION OF ANY W80LATBOse. c Asfrecere.sif asssass haneers here)

    • - 7 day average

Gonara anaqe r - Env. Affairs i.' Jw s ag 2.'2pgg

" - - ' - * * ~ ~ ~ * -

asmus_PSE&G NJOOOS621

-. - asr.sep meM 484 PO BOX 570 10C esamav numosa pi..c.a

. u

_.M.wmrk_SJ._fl2101 neoneronimo pensoo Salen Generating Station m

g g ower Alloways Creek F**"

Ub 09 01 56 09 30 auni in ni saisi aasm esses aan>

te0TE: meed teessueeless beenso semptomes ads Gesun.

(s read Oes,p ouaesisty om a.oaDiese se resus Dasy) eua4.0Tv on CostCafeTSaftese pamaasavam (43J 8 888488 888d88 443J 8 (8848) 8'*- '**"r**' %#' " g o

E A8sAhve.G (88J7) avenaes manimuu unite minsmum avanaes manessues usues y,

00400 1

usaev"eensen, 7.40 10.00 1 1/7 Ga

    • **.a e

PH Effluent Gross 6'.00 9.00 SU 1/7 GR 00400 2

eassee.s 1/7 GR "s*" a*"*"'

7.30 7.80 pH Influent osassar SU 1/7 GR noe u unessesor 50050 1

, g= e s,,,

146.90 532.80 CALC NA Flow Effluent Gross reassar CONT NA aseweesseessy MGD s

1/30 GR 00340 1

= s a.a u ce.s uamma"'

51.00 51.00 CO3 1/30 GR Effluent Gross peamer MG/L neouseassessy

~

1/30 GR 00340 2

emmets

=amevaamsar 84.00 84.00 COD 1

1/30 GR Influent resour ggjg l

i 00340 4

1/30 GR

...,6 s 0

COD 1/30 ga i Uffluent Net reasser 50.00 gg/t i

neouseassent

-I i

NOTE 50060 1

us A=,ts NCyIE NCyIE

.u sms==

gg gg 4

l Residial' SWS esamit assuanemoar 0.20 6

PERIOD Qt I Effluent Grrma y=..=.aa e,y,

  • Cn8"'s'a n'a~s 'a*m ins v a e'soan' naves. sumerito,.eanaT.*** * ***va n-- tv s aamm.assa Ma**H O 6 **

I amasse/Tevt.a passacapaa, smacutaws carscsa ase m ean a.co ma asaressammaa com 7

munuse, c,e s ons me.moua6s sansemassa on. esv

. on aros.

masava vs summarsso escannaren

/

8

  • I. TrejO assa c, e e D,od. Prot./Chea Mgr.

.m,.seu.,s,acc,,oma,es, a,no,,co.nses,,s,i,a. a,ns a.m.ans,,v ar,v s.ms nas 6 r.

u

.o

. ctua.r.

a o = m.

  • e..,,a e.

,,,,,,og, o,,,,,,,caa[Jaecurevs 609 339-4399 86 10 24 l'

,, ca n

o

%.. a,,, o.,

e4a

.a.,

a o,sc... amo s.

^""^

=> u6c e e,.;-

w.e a a.

4 o,s.cse on auenonsaso asent esueseem vana ano o.

em asse NTedbas or ap.y wackaTBosse leefereare me ass '-- heae)

Diccharge 484 is 321 condenser cooling water NCy1E: No sanples obtained due tO equipnent configuration.

Paes or go.am.a e o a

.c..av

, s use...

E semeserves asansary es eserams, havsowaL coLLuvANT,

snea staasaseAfsome avevens trepaJ)

(

4gwgegg rarente menestmensa-

    • =8 8 Ot$CHARGEti "ORING REPORT (DW23 gg mes___@. _21*___Dy

_W,_._________

is n.

< s r-

a.. As 2-2948 m _ _P_SE_3.G_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

!U0005622 484

    • c"'"*""""

c _ _

_P_.O

_BO_X _57_0 _1_0C_ _ _ _ _ _ _ _ _ _ _

_._ ___ _ W _ _ _ _ -.NJ._.Dl 9.l_ _ _ _ _ _ _ -

neomironino esneon 1

r.amur_ _SyaLGINgmTJNG.1 TAT.10tL _ _ _ _ _ _ __

vs..

mo v=A.

bugsg__JDG.JJJDE(1GGES___ _ _ _ _ _ _._

86 09 01 86 09 30 os ni in.ni eu ni os m on-se, os.n, esoft: need meansseems einesse eesumisene een essen.

o re,d oase s cuanverv on a oansae 44 (.,e o.s,s ouai.ive on concanvaaveoes

,AA4805,g3 (dd-ji) 4344I9 4 A4 43 5 4464J) gjeds) see. 'W,,M '

S OI III avgAASE M AElteute UtelTS es teelteuse AvsmAes esassesgas usesTS g

00530 1

..una

""^****"*"'

70.50 70.50 ggjn ij3o ca soLIos, 'Iorn SUSPE' ECD mmn ameneiamment 1/30 GR N GROSS 00530 B

.Au,Ls 65.75 65.75 E/L 1/30 GR

~

"*^*uas-ear qunq, 'Iorn SUSPENDED essasit 1/30 2

INFunE 00530 4

"*^*uas=aar 4.75 4.75 m/L 0

1/30 Gn SOI. IDS, 'IUTE SUSPDOED 30.00 45.00 **

1/30 GR c':'I'rNNr :Cr 00551 1

...,t.

<0.50

<0.50 1/30 Gn

"***u"*"*"'

PcIgnrnM tr.ms MG/L E M D R GROSS neeu.,

1/30 GR mear 00551 B

,,,.'u".".". u v

<0.50

<0.50 1/30 GR MG/L PETpnrnM fr.'DIOCARDON N

%u'sur 1/30 CR 00551 4

... La 0*00 0*00 0 ' 1/30 GR PE'IgnrnM HYDDOCARDON E/L

"*^*""*"*"'

EEUIER IEP peamit 10*00 i

meevinseeemt 1/30 GR 50060 1

===eLa

"*^*""*"*"'

O.12 0.80 m/L 2

Nmv m

CPIEEE, ' IDEAL 1

l ESIDUM., 0E esamer 0.20 rERIOD GR asovins= sat m apnqq vs' e**s

',g ag '.,u.",,,o,'."s,a,,g ',, a',,,*g,',-*' =',, "'.*aaaJ* ',g g a l =AmesnivLa

.=cient smacutive oericaa o -.

. o,

. oo

.-. - o.. -.

,o.

/

  • ~ ~ =.
  • * = = =

~ ~==

J. Trejo o='.a *.c'co..n o 'co

.,=. s e.

. ". s o.

..e.c us

.e o m.,

.., u,sc i... o

,,,,,((o., o,,,, c.,,U.,.coviv.

609 339-4399 86 10 4

~>

aro

  • <* us"*

e

.,ua s."=a ="

Rad.Lation Prot./Chan. M3r.

~ < *~'

=.~at 'o*,*,r.<.= su=-"*

.n o ou

,.., s,.

Li.

    • d"'"'**********'F'****'*d*****"*8"*"*'4***d****"*

OgreeCEA 04 AurgeOetBSO ASSNr 00000SSR VSAS 30 0 SAy vvPSD o# PRINv8D teasesses, Asse EEPLA8eAvtose of A8ev veoLArtoose 4*efe,eere dt ess 4amense heaep

    • - 7 day average No chlorme, total residual sanples were obtained 9/1 - 9/11 Due to its similar configuration to DSN 481, values are

,.a m w. oinnilar-hit sliahtly hiqher. 9/12 - 9/30 m ales were 14miod.

G 0 " * # C-

' nager - Env. Affairs ii n gir.se, q

aans PSE5G NJ000562 I_ 485 aseems PO BOX 570 10C esawar musessa p.c.. u

_.,3 e_w a r k,,,.yal. _f17111L _ _ _ _ _ _ _ _ _ _ _

neongyonsuo pgnsoo Salen Generating Station g ower Alloways Creek

'no" 86 09 01 86 09 30

. 2e-n. e n-n i e u-n >

cm m sisass (m.u,

se0TE: Acad husensealene bedese esagesung ads tesen.

(J c.,4 o.J,s euamusty on Loansme se card Omar) ovativv os cosecsarnaveons pgg,gggggg M JJB (3441)

(M)

(464J)

(36dJ) 88 o.

  1. "" op" PLa

==

..v.

(M)

AvsmAes M Aslad uas uh4Te MsNaasuM AwseAeg asAElesute WestTS g

00000 1

  • ^"_^8,,,

7.30 10.00 1

1/7 GR PH Effluent Gross esamst 6.00 9.00 SU 1/7 GR aneuseemmer 00400 2

,,,,4,'* n,,s,,,

7.30 7.80 1/7 GR pH Influent esamit e

aseuenessant SU 1/7 GR 50050 1

. sa.a = P'.8 230.10 532.80 s

CALC NA u.a s Plow Effluent Gross esaasst e

e e

CONT NA MGD 00340 1

same's g

GR 66.00 66.00 CO3 neouseensent MG/L 1/30 GR Effluent Gross psamov 1/30 GR 00340 2

.am es.:

"EA*uanasa' 69.00 69.00 COD g/30 GR Influent MG/L e

neousemasent 1/30 GR 00340 4

0*00 0'00 0

""^*"**"*"'

COD 50.00 Mc/L 1/30 GR Effluent Net psmany naevenessame 50060 1

NOTE NOTE NOTE Chlorine, Total 1

Residual, S6E O*20 PERIOD GR Effluent Cross ao aa " o' **= 'a

                  • o*

vs'sP'80***

aavs maassivsvi.s en =c can smacutiva orrican

+ c*a'*' 'as'o n*a=a *u*usie.' Teen sfuf onasaTo's'e b'usseTTED enga'*ss"e'aa<mp='s'a='s' o aeo aae f a at e J.

Trejo one,am c.aQudtf

,fo.f eso6,4,,seawe.D.uak b. ste.enE.Ota.it.t.yn.E.hfO,,es,6aB.k t

.,.o.A

,f-aov e o

m o.

A o,

ts, u

,o.

an.e,o ar.v a,na ams s.ac.

['T v a o.

609 339-4399 86 10 24 wees.roh.m c.c

,.is. a, o.co.m.as a ta e a,ae am, seus a una

.m, t a,

Cod. Prot./Chen Mgr.

ormwo.c o

nm.

m As oF PalesCIPAbLasCurive st y or so.a as.

648 s 5 aoD

..a..

. o esponosahaf fel.

_e u,b t..,

,o aseo Slese

>>u c

    • '"****"'"*******"**'***d******8***88***d*******

oFF8Csa on Auf teoAlasO Ae4NT soutessa vgAn us on.

vvPeo on Pasesuso Caesasses Aaes smetAseartoes oF ahy wookavsome ( Asfasease.4 ese 4mmeans Aere)

Diocharge 485 is t22 condenser cooling water NOIE: No smples obbined th= to equirunent configuration.

~

caos or

.u.nu.

.r... on to es u.so ensei.acsa sea ro.= v.4e wusen may mov es u.so..

m we

i l

s MatsoesaL poLLUTABei mm.a steestesAtecos everens stPOAJ) pW' l,emeserves esAess,

'e.e esers.de t

e=ss cesCHARG2I

.TORtwG REPORT tear 2) p,g g serenJommri maa-anses _

11_R._, _,,DE:_,A,_W._ __ _, _ _ _ _ _

G o so.

(8 7.** >

,,,,,,3 2848 asemmas_ _P_SE_&G_ _ _ _ _ _ ___.___ _ _ _ _ _ _ _

U0005622 485

_P_.O__._B._O_X _57_0 _1_0C_ _ _ _ _ _ _ - - - -

_ _ _._IDBM. -

M 92.Ml- _ -

neowevonswG. Pensoo rasmu__Smp_Gr.N. f,NLT,DC. STATI0tL _ _ _ _ _ __ _

amea'ameL. JO El MJO Elf G El@_ _ _ _ _ - - - -

86 09 01 86 09 30 os m in-m os.m os m ou m emu, sooTE: cens enemmassess bedese eemgoeshe ein Gesen.

(J (ar O.fr )

Ou Aae T e T V o. LO.Osa.e te (a.d One,)

Gu ALSTV 04 COr.CS.eTC4Ttees l

PASAmesTES Id0^3II IId4Il IIOdIB 4dO-3II (384II I'"m*

.e. r, e

IN'NI AvgAASE M ANIM UM uMITe M8M8esues Av8AASE MA33M4fM 4fMSTS 00530 1

eanna 67.75 67*75 SOLIos, ityrAL

ngjg, 1/30 GR SEPE2ED

,enweg moeuseanmer 1/30 GR N GROSS 00530 B

..,La 50.75 50.75 E/L 1/30 GR j Arn.T m, ityrAI

,emm88, 1/30

';R IIFIIDff 00530 4

i as**uas"*"'

17.00 17.00 m/L 0

1/30 m

...,L.

soLIns,.ItyrAL SUSPDOED 30.00 45.00,,

1/30 GR Ir isWP:Cr 00551 1

1/30 GR

..,L

<0.50

< 0.60

.u..

.=,

e PC'Isrw n M fr. m NG/L EFFILENT GROSS neevenement 1/30 GR

<0.50

<0.50 1/30 GR 00551 B

PE19rwnM fr2DROCARDON MC/L IlGTIENr

_ ***" 'vent 1/30 CR 00551 4

0.00 0.00 0

1/30 GR pg.rprinM N MG/I.

EETIIDff NE"P

. r.eness' oat 10*00 1/30 GR enem 4

0.05 0.26 2

NOTE 50060 1

we..u"as'u's=,

  • ^
  • E/L OHIXIIE, TUrAL 1

IESIDUM, OdS

)

neevenement 0.20 PERIOD GR N GROSS ves.opmone eAye

. c e ='*

  • u~o= = a a** ",e s.s.*o.*n=.s.'tso.'. Eue <v1g o.noaa* 6' a =aa=.so or

~

.a asa mas.amuts panace,aL suscutivs o,,ican es as se e e.e4o a.e.as a.aen a enaw a e es. e.Qu.nv of f *.ot wess.6 6 mesED

'f L T me N G Fom

.c'cu... o o 'ca

...**== =. = =

  • v.<'..e *a..a m..a ~. o.=.=.a '.e=

/A jd um J. Trejo o='.a.a

.u.

padiation Prot./Own. Mgr.

..c a.o.'a = 'o*,*,= 5-=-" ac ' '.*.** u s' a==a 's=c e ". '."

,,,,g,o., o,,,,,c,,Ai.4macursva 609 339-4399 86 10 24 a

.o o

io o s c....

i

..,.,.......,.,s

.,,,c...u....-,

es.

...e n

j i. _...

o,....

. ~,

I j

No chlorine, total residual canples were obtained 9/1 - 9/11. 9/12 - 9/30, sanples were 1/ period.

Note:

Gonora

,.[ nager - Env. Affairs

. r.

t er.c, g

PSEr.G HJ000562.

I, 486 AAMEN PO BOX 570 10C reamer numean l

.c..

%_ _.M ausa rl _.EI..fl1101_ _ _ -- - - - - - - -

neomvonswa s.gnion Snlen Generating Station g

g g ower Alloways Creek raOaa 70 g

g g

g g

y l

inn e in u

<xn,

<= m sis.se. < m u,

eseTE: need bassassmene asense semiyasene ads essen.

(A rard O.Jp3 Gu Aser:Tv om LOAOsa.e (d re.d Oet) suAL4rv On CoseCSaevaAv60se

<au,

auss,

< aan,

< aw >

<ua,

  • g. ~~.;;~'.' *g,n =,l (M JI)

AvsaAG.

es AEstium Utelfs assNIMum AWamAss AAAEtteWeg uge4TS gg pg e'

00400 1

..f^""8,,,

7.30 7.70 0

1/7 GR pil 6.00 9.00 SU 1/7 GR Effluent Gross 00400 2

u s A.a = *e.a 7.30 7.80 1/7 Ga s

uas s=,

pH 1/7 GR Influent esmesev e

SU meevenessess?

50050 1

.amns e

CALC NA 185.70 532.80 measuasma=T Plow 9

Effluent Gross essestr e

e CONT NA MGD neewesenseser 1/30 GR l

00340 1

e m aa.auna 80.00 80.00 veammar CO3 1/30 GR Effluent Gross ease.sv e

e MG/L moeusesc4essY 1/30 CR 00340

.gu n,s,,,

120.00 120.00 e

COD 3/30 Ga Influent ceanist MG/L e

eseuesiasseur 1/30 GR CO340 4

  • ^"""

O*00 0.00 0

""^*""*"*"'

COD 1/30 gg Effluent Net peansiv 50.00 ggjg neousannteset 50060 1

usa. eta

. uammaar g

m g

j y

1 0.20 PERIT GR Effluent Gross aseuseement

  • a=
  • * =aa=== a T-' - -

eavs

(**'.'. 'f.".a.e.m is T.es e'.r on 'T.D '. b.u.e E."gets. ' o e.ean

. a**

a ' = " o

.A smvi.s eau.ci,Aa. anscur Wa Orrecsa o

D

.va neo ro.ma. rom

/>/,f s

iggy agm J.

Trejo o.sse.c. e

,ot 064.o s.n.woouh

, e.Qu. e or

.o maiarve v m.3 o,..o.. o =,.,

,sc..co..c,,

n.,=,.s.,o.eo non

,o. s.. a.e c

,,,,,,,g,,,,,,,,,,,,,,(an. coy,,,

a a

u.

.o, c

609 339-4399 86 10 24 n

eu cum.

CCd. Prot./Chea Mgr.

~. as o

.v

>>v.c a

.e

,..,,s.,

^"*^

m

.c 1=.s

. ei -.

Orrsesa on AuraOmisso Aesser esueseen vsaa eso o.

em Aaes _ __^r^vteos Osr AssV wSOLAv G 6 i AaAsevera N ers ses sasa er,a)

Diccharge 486 is 823 condenser cooling water NME: No smples obt-nined 'b to equipnent configuration.

PAes oer

.. a m m 10.s u.a.

insei. Aces sea m v ww.cn =Av =Or es _r i g

20

see dieseener MAf toseAL PoLLUTAsek eeA.eg 3Leestesafeces 379T30 gWpp&J) ggg pgmesarygg psa.eth.y Farens, m.me/t sans p*"'8 DeSCMARG3 ITomeNG REPORT DN2) ggg mens _ _ _%M. : C_R._ _w3.._ NT_._ _ _ _ _ _ _ _ _

"c easenoen asemus_ _P_SE_&G_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

U0005622 486

_ _ _ _ _P_.O_. _BO_X _57_0 _1.0C._ _ _ _ _ _ _ _ _ _ _

""a"*"""*

__ _ _ _.NDWE _ _ _ M. 91ML. _

wowirommG

,ER.oo usa.ur_ JSEEM. _G12 DATING. ST. AT.10tL _ _ _ _ _ _ _.

-o v

?

mvast__IDE NJGIMS.QMS_

86 09 01 86 09 30 eis ni enjJe eid ni easirn sie as eisLn, RIOTE: Reed losaseadoms bedese seeigsteeng eds Ossum.

i e s c.,a o.#, s ouamvisv on Loaoene se c.,4 o sre ovatstv on cosecsarmareces

(** 8 8 8 888 488 8 88d88 8**Ji>

88848) 8g " *. *. *, * ". *. '

    • 7,7.81i paaame,sa I

III*III AWERAGE ed Aslee ute UNITS b81N640Ute Av8AA48 MAstesget Utsegg g,

" i 00530 1

me s.ameLasar 46.50 46.50 vaan

' NDS, 'IUTE g

ij3o a

i SUSN as e.nm.e.r p

. ewt 1/30 2

i eg 00530 B

52.75 52.75' E/L 1/30 m8

"'^*""*"*=v qv.Tm,

'1 Urn pente s?

1/30

'41 13anIsWP 00530 4

...n.

0.00 0.00 m/L 0

1/30 m

SOI. IDS, 'IUPAI.

SUSPmDED

,s 30.00 45.00 **

1/30 GR Cy; risWP 14:T 00551 1

...,t.

"sa*""<"*"'

<0.50

<0.50 gj3o a.

PCIgnrn M If. m s NG/L CFFIDE2ff GROSS ns.v..,

ment 1/30 Gn 00551 B

,,,,.'u".".".=,

<0.50

<0.50 1/30 GR PCrpnrnM If1DROCARDON MG/L i

INI'llE2ff

,,,', "",gume 1/30 CR l

00551 4

... n

  • 0*00 0.00 0

t PCFpnin M m E/I.

1/30 m

EFFIIE2ff NE'r no a.neser p

10.00

nemen, 1/30 GR.

50060 1

me.e.aans 1

0.03 0.18 0

une sm, M/L Period GR OHHtItE, 'IUFAL 4

i ESIDUM, WS

pense, 0.20 OERIOD GR i

N GROSS ua a ai ' or === === - * **

veLePMONS SAya ma sivens c.. c.e4L suecutivs ocrecen

. Ce=' ansm<=ea=m me~ tee toeg esp osmateOsa Summf14.ano-a.ss e =-o asEB aae f seE 4 s easD GaMO one est m =mv ce goeced sadaveuma t samatenatste atNE FOA aa6 'a

=* *a 'ea a as t *

  • a *==="s o== o== 'a='

J. Trejo

<='v*aut e ans 'acamE sh aCCumata aseO Comargggg Teest Westas AM Sdk l

a c

u s'o.. o'sc==a ea a.a.=.==.'a.a.

,,,,,,g,,,,,,,,,,c,,ae.'d acu,,,. 609 339-4399 86 10 24 nadiatica Prot./Chan. Mgr.

'.=.' < ~.o a.a a.at 'o*,*, r.o.aa.s.u==n.ac

..e i

e

.o

..,o s c..... e.

..., a.

.,., d w.., as s m.,

,,.c.. o.i auvesoaisso masser

- r --

Ivaan u

.e -

..e.....

COasenteel Atat EmptAmaTgoes oF AMv WloLAYloseS 4*t8e'eare es# 888ese hemeere 4*'#9 i

    • 7 day average

9.., a...a.

r.,u,

-a....a..,

S= *rseemet

=a.....i..~..

8 pasCHARG3 j TORING REPORT apad23 j ((

,4 Gnnorna

.neger - Env. Affairs si n.

e sp.n W88

~es 2-2SM M_P S E EC NJ0005622 481-483 PO SOX 5 ~10 LOC rammeT mumean

...c.a a.a a

Newark NJ 07101 040estTORING PERIOD Salen Generatin9-. Station vaan no oav vsAs no mAv Lower Alloways Creek Pao" 09 01 86 09 30 4Jo-n i e n-JJi eJd.no aJaira sie se, ms:,

000TE: neesi tosenseelsen hedese sempioehne ade tesen.

(J rard O.Jp3 quaseTITY om LOAD 88ee (d rard Oah) euAL4T7 om CoseCs8efeATieel eAaert a]

PASAmeTeA MJ4 E344f6

( W J)

(46JJ) 4364#)

suo.

    • em 88 TYPS (gg) anas,...

Avsmass m Amine use unste esimimum Avemass asamaesuas usuTo 194N

ted48, ged Fars 00010 2

>,f4m,,P,',a,smi 22.80 23.50 CONT NA Toop Deg Centigrad' q

Influent DEG.C CONT NA 00010 1

,,,84",,%*,,,

31.20 33.80 0

CONT NA Tsop Dag Centigrado si Effluent Gross

_Penges T_

43.30 DEG.C CONT NA.

L 00016 4

s4m ets 7.90 10.20 0

CALC NA

"***u"*"*a' Tcp Difference Effluent Net Pamess?

15.30 DEG.C CONT NA naeneessenesst emosen.a mesmounsaeani PSSesIT neousaseneser eameos a4 EAsu A$te SNT

.. j PStu f f eseusesseseef eassets u sasunau s=v PeansIT neevenaseest sansets usaeunama=T PdAedIT Acouestesesef e C6atWV t, nota reaasTT of 64. Toma t e awg egna.na.a. tv gggg,gggggg gg9g i

' eseess/TsTLf3 resseC8 PAL sESCuTiwk OFFigga asso ase taasanaa entes f et swasmaatoms bummaf1Eo. assam a.saansato

~~e no ma6so ons.sv esousav of tesOSE pdlDweuma b seemetonaist y ag &posstsam 8 FOa am..s.as v ar o =eomaava.

(609)

J.TrOjo v.i

-rvs sma ans me.

anta. va oevaa <. va ** o==av a.

.6 eaua accusava ano co-t:1 s

sumari.<. a6sa area ava. ac **

339 4349 86 10 24 v s.monae..u..s,tio n e.om a soo'. a"n'osise=Avfs or ca Cseaa. anCufswa Cod. Prot./ Chem Mgr.

an caas

  • e ma u ce

..n o a ca on aar nas se u,ms o

.a aa

.u

-.< nr.. s

.,m.

o,rican on Aurmonisse Aes=T esuesosa vsAm eso ea,

. di

-u

,,,g.

,,,n,..

Psesseef Asse Eart.ANAf toes or any waoLAf toose e Aefereere em m sh. nears here) 481-483 is unit 31 condenser thermal monitoring data.

=

m

l l

m

\\

F m.,, n.

3,

.. i s s,

seaviuau. euu.uir.=v smo. sum m...o= c :vses irruas, l amen Je==rs

    • =88 DisCHARGs L ORING REPORT assac;

,%y. m

' g m.4

!eus Genorni

.n nLe r Env. Affairs o et.

t o y.,

t

t.. em 2-294d BHRH PSEEG NJOOOS622 I

ggg_4gg; PO BOX 570 10C

    • aae*T mumosa

.c a.

u.,e..

towark NJ 07101 e40NITOatlNG PE R SOO g _ Salem Generatin(Station I

Lower Alloways Creek Fao=

g 86 09 01 86 09 30

(

.n ni in ni euns en m en n,,wu, es0TE: amed ansesmestems basass sempesume ads assus.

~~

as card o.s,s ouanverv on tomosme te card o.ars euausv on coescanvaarsees pggg,,gygg M JA3 (34486 iA84J)

(se,$J)

(364J) eso. #***",,"**E' Saaseth g

85 Tves 4 3,87) ama.

avsmass wasimum unite essaimum avsmass asamassues usuve a

g, lO0010 2

,,,y,,,s,,,,

23.20 23.90 CONT NA Tcop Deg Centigrado

, Influent

  • sesse?

4 DEG.C CONT NA I

seeeeeemeener t

00010 1

eauets

""^****"*"'

28.50 33.40 0

CONT NA T0op Deg Centigradg Effluont Gross 43.30 DEG.C CONT NA 00016 4

easses.s

""^****"*"'

5.90 9.60 0

CALC NA Temp Difference Effluont Net peness?

15.30 DEG.C CONT MA meansenensess7 sauros usaeumsmauf PGA4887 neouseensesor eaues.s

.A saeuhsM sNT Penesse nee,pensasseet i

sanset s as sasuftsM sNT PSaasIT neouseensass7 eassei.s usasunsusaw 4

PapasIT matulemee88T TELEPseones D475 assass/TaTLS PenseCapaL smacutivt C#Fracsa e cantar useota pse.a6sv or saa vs.at e o.ava ramaos.a.sse a saamsma0 aos F ameaeam mates voeg essponneavaDse humanvita essag e aseD es&&D aaso.se eses m: W^

rost

.o cometrus. m. a smaTEtv.viso rom.E.avea

/

(609) as D.weua66 caQuelty of teeo64 one J.Trojo e'vs=4 acconava a.av.c aste n v.

sum o am ar. v.*

no

.as v sv v. ma nas s<.

6u==rvac. Passa aro==aie= act 339 4349 86 10 24 l m==

mas is u sc a icoua=<-

seenavufs or enencipas. saMcutivs Rnd. Prot./ Chem Mgr.

=== =c aa' **.'naa v a m. r.o.a ano o

r or. ano 4

.u.c......

u, o,,,cs. on nurwonsaso r--*

_ " " ^_

eeuaseen vsaa eso oav n

^

m

., a.

. s

                • T asse SEPLaseATeoes of aper wookaTBosse (Geforeers.4 es sse.neess Aere) 484-486 i s unit 32 q,pndenser thermal monitoring data.

- = =

=

_,__c-

.See (sers.use NATlOS.4L POLLUT1NT

. Ameg gLgegDS$ATleet SVgTWIG (%PDS$)

g s smessTTe.s seAas's, Far.ame Re ne/Leres dW m e88 DISCHARGE 6

.44TORING REPORT tsafat ggg naus _ _ M.r _MGE D_Ws AFF _ _ _ _ _ _ _ _ _

u 8+i uf-n>

2 ggym g,- pSEs.G RI0005622 Fyc pTOT FOT37F-W ---------

Ps MiT =UMess c..

E u NEWJtK RT 07101 wontioRINo esRooo g&qi&lII NNW__E__U_@ _ _ _ _ _ _ _

TEAn eeO cv vaAA 00 0 DAY MKAT.Htst_ _Iqql_ATJ_IM_YS, _CW_ _ _ _ _ _ _ _ _ _

'"*"l86 09 01 86 09 30 iwn, in-ni pe m os m usa, < mni NOTE: Reed tumuseums heaue esmeteens een suun.

(J Card Only)

OUA8.TITY On LOAOING te Card Om43 GUALITY 04 CoseCSeeFA470e00 PAAA40ETER

(#3II IId4II IMI IOI (MI

'.M r -

su m.s IIIU)

AVERAGE

  • M AEIM und UNITS telNi40Ute AWSAA.E teAsateWeg UsefTS g

g, g,

"E U

.=T 7141.00 14431.00 0

CAIC NA 1

MIM OF M IEl IKXL't NE!P

'iT-

' '-waa

,,,,E.,

l EFFIE NP NEP

            • '*'T M600.00 te1UIR IDmi NA I

l oAasPLs es E AsunameENT me U.esman?

. AM Ptc asEAsumEasENT m

me Useensam?

C

. AMPt E MEASUREMENT

.,f-7 meGUlpenses?

.AMPts MEASUREMENT W IT neeUensuswT

.. M Pt E MEASUREMENT

. PGA00GT neoueaanauf 9 AM PL E MEASUREMENT PWlf as2Winemsuf 5: Ate 3/ TITLE PftlNCSPAL EMECUTIVE OPPICEA

. Cas.t.sv.u or.n. M ttyest T E e Fos T s.p enesO or t.m

. H.vg gamo tty a sugo m

,A,g i

.N eF

.at

.s.vEmA.T.O h a-.*TTED f ets.

l oDv ts e.fDs.ftty ust N E F(m J. Trejo o.sv,.,.c.cc.m...n oT O.SEvo tive.

v.m.s.um r,vio

..o.n. Mar.a

/

e.Qu.sv or i

enew a

=t.

u v

v

, o co

/

Radiation Prot./cian. Mgr.

609 339-4399 86 10 24 n u. c..m..v t v.,...o.n s.o rv c

.t.u o.. ia.u,sc i io t.uo.m.i.o

,,,,,g.,,,,,,,c, PAL ERCUTive c.,o.

a ue.

.c o

me u...

.a---

---.u,,

o

.~,.

..e u

.,,o serp.Cs Osi AuT osisuso Aess Y ssWeseSimi vuAsi ese

.AT a...e. -.

,,,E,o,

,,,,,,E.

COSSRSENT AND EMPLANATION 08' ANY WIOLAYSONS (Referenre N m..e.re eers here)

FAC IS STATION HEAT RELEASE l

s mAus esse (s.,s de

=AveOus. poi.e.urs.=r uAmes si.eme= Avion everuse a::ross)

.. Agusused entr.a.s,i w a-

    • = )

pesCHARGE.

4. Tom. Die AscoRT (Desa)

,,g gg, m anism, u umas _ __CEN,,,, _n_ __W;._ _AE_.

(mi 187-8*)

g,g,g,,,33ag MJ0005622 48C Ameages_ _P_SE_E_iG. __ _-10___ ___ _.P._.O_. _BO_K_.5._ _ _ _ _.1

___._ _ _ _ _ __0C_ _ _ _ _ _ - - _

esaan au=osa c =*a======

__ _ _ _ _ N _ _ _ _ _ _M1.__.92_la_1_ _ _ _ _ _

uonivo no

,En oo raGurtIY_ _SMLM__ CELE _R_ERC_ _ STAT _I,_,_ _ _,._ _ _ _ ___

W ya,

nasavutes._ __IGLE_R_.A, J.J qS,_ _ CREE _K_ _ __ __ _ _ _ _ _ _

86 09 01 86 09 30 imm m.m <*m osm emm emn)

Isota: need massessk+: taesse eseessais een essen.

(J Cmd Os.f,)

QU ANTeiv OR LOAO8MG (d Ceuf O 5)

GUALITY 04 COpeceseTSATeese PARA 8ssTsa M 3J)

(344f)

(J649)

( W J)

(jedf) 88 8.

SA88 K.8 S

g,F E

TV5 assat y.e.

I I

Avsm.Gs M ANIM UM UNITS AstNtt0UM AVsRAes MAEastfet testETe g,

00530 1

.A.ns "s**vement 17.20 28.00 0

2/30 2411C w w.Trn,

'IUPAL bG/b I'

~

SUSPDEED panesw 30.00 100.00 2/30 24l0 EFITIENT GROSS 00010 1

...ns asasua==sar 25.10 32.00

  • p 15/30_ GAB TEMPERARIRE DEG. CENTIGRADE penun (U3. C KNIHIX GAB EFFrIEWP GROSS 00551 1

.A.

a

" " ^ * * " * " * " '

<0.50

<0.50 0

2/30 GR pimYwFIM HWL r

~

HYDROCARBONS peamir a

~

10.00' 15.00 2/30 GR EFFrIswr GROSS 01042 1

...ns

"***u"*"*"'

0.04 0.05 0

2/30 241C

COPPER, R7IAI.

MyL

- + _ -

1 (AS cu) n 0.2) 2/30 240C <

EFFTIFNP GIOSS 01045 1

.Amns us**ua===av 0.61 1.10 1

2/30 2pf3

1pm,

.ggr3I, (AS FE) penesn EFFrIENP GROSS 1.00 2./30 241C l

50050 1

mea.ns

. uns===v 0.14 0.41 0.72 C3rr 4EAS y

-?.

. panesw QNP WAI I

EFFIHNF GROSS 00610 1

maa.A ns

. uas-sar 18.50 26.00 0

2/30 GR a

( AS N) eensen

~. U -

35.00 70,00 *~

2/30 e

EFFusarr Gpnm eavs

. gag'.,._.u.a== =o,r tgaga.- o,

.,.,=,.,,o 4 =u.=

y,,g,,,,,,,,,6

Amsmns renacieAi. sesCuviva OeveCan o

..u.,

arm.spe t

o.S..s.s.esG.c.v.,om

.,.,,c.,o c =, v a.r c a..o.s

,,M, t a v.,. >o,.,,o,. ca.,o _

_:,,,,.,..,,,.u.c..c.oua.ns,,,,,,,,,,,,,,,,,4,,,,,,,,,

J. Trejo 609 339-4399 86 10 24

=

.,==. =

n

,v Radiation Prot./ Chem. Mgr.

.o

. u. c...,,,

,.,, s s,.

.,,, Cam OA AUTesoggasse AesseT getamesp vgagg ggg ga, n

Comess pet AMO sket.ANATION *]F ANY V80LATIOpes (Refe,rere es essacha.eers he,eb a4 8C is Non Radiological waste treatment l

,seaserTes Aass esse (feringly NAYBONAL POLLUTLMT 4Ames eL80860sAfte88 oveTSS (#P983)

W Farms #mme/Ler=86 J'f*=es s ogSCH ARO'.2 e 41 TOR 4NG KEPORT (Sera) ygm natsg _ _ _Cfd.__D_._r_ W.:_AFE..,,_ _ _ _ _ _ _ _

al*>

(874*>

Emphus 32948 G

Asengap_ pSFJt _ _ _ _.

M70005622 48C

._P.J}.,_ AOL.5_7_Q_

10C

    • c"'"==

W-----------------

640NITORING PERSOO rag;m,tIJ_ _Syg4_GR@_ATINE _STM'_IW

,s..

.O

.A, v.A.

.A, mTm._pJg_ALJ_OR_Y_S _CREEX___ _ _ _ _ _ _ _

86 09 01 86 09 30 imminmenm (a m imm (mu,

'as0TE: need husbueduas bedsso eseqpleens in GesuL e

( A Card Only)

OU/.NTITY 04 LOA 0$NG to (mef Omfy)

.UALITY 04 COseCaseTRAfeese

" 808'L PARAbesTgg (46-3J)

(34473 (J8 dj)

(46JJ)

(jddf) 88 9.

er, TT**

em (32-37) 6 AvsmAes M AMIte Ute Unite 08880640Utd AWEAAes geA30glung UgefTS g,

gg, 01092 1

.Amns "s**uas" sat

<0.01

<0.01 0

2/30 24HC ZINC, 'IUPAL g

(AS Zn)

,onen, N

r

~

a***'asse=T 0.60

  • - 2/30 24HC EFFrmir GROSS 001032 1

. A ns us**ua====T 0.03 0.04 0

2/30 24HC CHROMIW-lE:XANT M3/L i

neevensmswr 0.14 2/30 24HC G

24HC 00340 1

.s A.Auns Uns===7

<10.00

<10.00 0

OEMICAL OXY N DDEND M

2/30

=J""""n 50.00 /

2/30 i

1 00400 1

,,ffo",",*s=T 7.30 10.00 1 18/30 GR pH (Compliance pt. )

SU m

y I

nee'w'"e""eEmwr n

6.00 9 00 1/30 GR e

00400 m ell".7."s=T NA GR 10.20 12.20 g

gg runwIER EE.

venement 3R GR us[.u"nIos sur M

1M E

gyg BY i

IC-50 (96-HR) (M.bahia)

. emesser y

"8'"'"*"*"'

> 50 -

W)L.

E -

u s a.a=PLs C

Unsus=T neevinemesse gas.se2/TITLs PeaseCIPAL sesCUTsys OFF8Can e cassev umsoen eve ats, or taar to.at e eenws pse.asentty saassseo N

.Aya asen ans taasanan umstu emer esomasaisuse tuemeTTso eenases amo essee On e manwsouatS

. v es,u.,,sa,ve,.eNam.m,a,aq'm.s.s in stemattav.r o, e.asv asuou..sev.o,r to.eOG4 m

accu.a., o a.oca t,,.,.,

J. Tre o a

,e a

"*o==a" 9 "GODI 609 339-4399 86 10 24 Radiation Prot */Owm. Mgr.

a*'c a

oa Su=~rma * *'"

'ctus==

"" *o*,* r.'est e.

,.4.u,S Ce.,...asa.m.

gggggghgg gy pggggggpag hygg,g

> > u PoG6e. t eT T ipet aseo _- -

'a===8 NT ME e

c.

and * 'as s**a*

  • pas =**=ra8 4 *
  • 8 88"*848 8 ***M 8 OFFICsa 04 AUT"MEO MI MM M

M M

TYPs0 OR PAIN 1JD COceae#MT ANO EXPLANATION OF ANY WBOLAT40see 1 Aeferrare ads meses 4.sients here) t available g loassay ocmple{on. trol group during Bi sav,resttlts arap ter. Ioss o con water prec acc tion to receiv

'aamse **==i g......A

.,v {...,-

d.

AT.O~A

,0 uu r Q...

. u.O

.T.r

.a u)

(#iw.

i

'" 8 DISCHAR tr TORING REPORT t

)

gg g

0 mentas_ _PS_ @ _ _ _

1U000M22 487 E

_ _ _ _ E.9.r B_OX _57

_ _ 10C_ _ _ _ _ _ _ _ _ _

  • a" ' ' """ ** a
      • c a'*** ava ** =

M2EBtL _ _ _ _ til_Q21QL _ _ _ _ _ _

ouironina panion

'm_

S._AII_M_GE_NE_RA_TI_NG_S_TA_TI_ON_ _ _ _ _ _ _ -

vaan seO oAv veAm mO oAv ma'Ja81_ _M_^F @_Y. S_E_ _ _ - - _ _ _ _ _

86 09 01 86 09 30 ao ni in.u eu.m in m us.m vs.n, ItOTE: Reed basensellens hetese emaiptedes Sie essen.

gs Ca,d OaJy) QuANTITv 04 LOADING to Card Omfy)

OuALITV 04 CO8eCENTR AT1006 a..e"r PAAAteSTg, (46-JJ )

43443 Ud43)

(464J)

(addl) 88 0 OA00 L8 g

6v IN*NI AVERAGE M AEIM uM uMITO MIMitsuM AVERASS NAEltluGG ut04TS y

gg, ggg 00530 1

...,L.

" * ^ * " " * " * ",

18.00 18.00 0

1/30 Ga SOI. IDS, 'IUPAI, SLEPENTEn E/L EFFU D E GROSS

      • "' ament 30.00 **

100.00 1/30 GR 00390 1

u s A.A= PLs 12.00 12.00 0

1/30 GR

u. sus =Y CHEMICAL OXYGEN DENAND m/L

~

98R8881 100,00 1/30 GR EFETJHWP GROSS meeviasmear 10551 1

,,f,^o",,?,*a T

NOTE 2 NOTE 2 NOIE 2 PETFLdELH E/I*

gyg,p HYDROCARBONS

,,,",,",",' ' ear 10.00 15.00 1/30 GRi EWHBWP Nc

  • ^
  • s 50050 1

us Asu"na'm enf NOTE 1 NOIE 1 NOIE 1 FIIM ED

~ ~

PEA 8017 1/30 GR EFFUEff GROSS

        • '"*"*"?

00010 1

. A.,os 0

V30 GR

"*^*""*"*"'

33.00 33.00

'IER DEG.C PWebteIT 1/30 GR EFETIEWP GROSS nuovexamsar 30.00 00400 1

,,,"fo",7,*saf 7.20 7.20 __

0 1/30 ca pH

, mamit 6.00 9.00 1/30 cn EFFIDENP GROSS S AM PLE ME ASu Rete ENT PSAe817 asouinament TSLSPMOesE 3Ay3 esAmeS/TsTLE PasseC8 PAL SESCuTIVE OrrlCgpl tat to.at e avt MatoseatLv.s aa.es.Eo

, e.(.o.a.av unos a ps at tu o.r t ae es.InwsLasatS se.u.en nto. ease.

a e eauo

.romuavon s a

e ram.Liam ent va a EOsatsty mE5Pos.6sett FOR oss eT e.QuenT Of Tee 0EE J. Tre3'o "s s'e*u*s'ac'c"u'sa"va m""ec*o"neet sia*e a.a 'm"e'iana v"'"r 'tus"es a"a"rss"

/M

/

i a

Ibadiation Prot-r-

". 'e'c'c"o's

".t.v'.o,.'.o." a.Sua.".'.".".'o ' '='>" u"s i '"u s c" e "o'."*a"n'o

,, o,,,,,c,PAusEsCurivs 609 339-4399 86 10 24 c

. u s c i. i i.. e.

,..w,,

..,,., i,..,

s.

Orrican Osi Auf--!:so ---t seuseessi vsasi

.Av ii

- r

.,a,

..a e.

CoastSEseT t seO EEPLAMATIOes OF ANY WIOLATIOpes e Arieteere mal eas rkmaansa he,a)

Note 1 - Physical modification reauired in order to obtain data.

487 is the HHB yard drain measurements are obtained only h sanpling protocals are met.

x -, n== a 7 a A,,

O.

pseesg CEse (forhade N AT4084t.L POLLUTANT' seAmes EL8M8MATB000 SYSTW8 (%7984) es W farsaw,TTEE esAteI camw/ tares Jefeevo)

DISCHARG2

.ITORING REPORT (DWI) ggm naus _

@._ M R_.__DE,:_ _Aw._ _ _ _ _ _ _ _ _

is-sel t ##-I'8 G

Emphus N H d Agenges_ _P_SE_K.G_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

R10005622 87A

_ _ _ _ _P_._.O_BO.X.__5.7_0 _ _ _10._C _ _ _ _ _ _ _ _ _

      • c"^***va'**=
      • "n "U"**a

_ _ _ _NDERE. _ _ _ _ _ RT_ D.7101 _ _ _ _ _ _

uonironino caRion g&Gts,tI.L _ M8hDi_ M M _ _ _ _ _ _ _

v5An esO oAv vEam eso oAv saGavm _lDER MJ4HWS.CBEE ___ _ _ _ _ _ _

86 09 01 86 09 30

< w ii> o m i osari osm usas, euss, NGi t: need ensmusenes hetsse comptelhg tes Issut (J Card Omfy) QU ANTITY On LOAOsNe (d Card On%)

GU ALITY Oft COS8CENTRATIOSE PARAGGETER M III (I84Il o0"8II 480J3)

(384I) gy

  • =

Tv's IEIII A

6, AVERAGE M ANIM UM UNITS MINlt4UM AvsmAes esAEle8Utt UsefTS gg gg, gg, 00056 1

i m EA.Am,La UnamENT 4643.00 12691.00 0

30/30 GR gg c

GPD

~

DhILY GR me=U NOTE e

Ewrmfr GROSS 00310 1

. E A.u"n'u'E,

89.07 0.65 31.00 O

3/30 GR

  • ^

B00, 5-DW IM9-MG/L E E U.Dff GROSS

'.'3E7,

>87.50%

0.97 day 1/30 GR 00530 1

. Am nE 4

""^*""*"*"'

5.30 8.70 0

2/30 24R

SOLIDS, M

SUSPENDED esmatir MS/L 1/30 2R 30.00*

100.00 EwrN GROSS

  • ^"
  • 74055 1

.EA.U.".ENT 0.00 0.00 0

1/30 ca (YW.TFUM-FECAL

, n.

N/100MI i w 200.00 400.00 1/30 m

EwrmTP GROSS 00556 1

= Au nE Oil & Grease 1/30 Q

Mg/L pene:T Effluent Gross neeUsmemsat 10.00 1/30 Gt 00400 1

.EA.U.""ENT 6.00 7.00 0

21/30 og 18 Su I

. PGAtSt?

d 1/30 Gt l

EFFrmTP GROSS 6.00 9.00 '

i SAMPLE MEASUREMENT PGAe847 REQUIREB8830T g

i l

N AMS/ TITLE PAINCIPAL EEECUTlvE OPPICEn e cER'av useorm es peat s, or taw is.ar e navs presossatty s maasesto TELEP900NE DATE asen ans taaseteam movie y,eg serosasatsOM sumanfftD pegsges aseD SaGED i

Ope My ecouemy or TeeOst eeCaveDuett sesneECmaitty aterossedEE FOR i

J. Trejo O.ST.a.sseesGaccu.a.u,FOpesavaD8e,,,,e,,e,FLe,Evf Te.st SugamT,TE,S,.e.s.FOA.nsat.eOne

/

Teet o u

a,so co a a a

,,ea a

e

==ctua-a 609 339-4399 86 10 24 f^ !

Radiation Prot./'Chan. Mgr.

  • ","s'p"'sse"t.',',"o,,'.o," a,5"*'."".e o,s.'.c'=',58 c

su""is"u*c" e soon maso eseMvunt OF PasmCIPM EEECursvg "s

,e o

e so e nusctiuo,e d..a,.,

. css,s..,

ssesm.

TYPED OR PRINTgg sad a' "'* **"'** **P****e*** *d Ad*** 8 ***84 8 **d 8 "***

  • OFFICEA OA AUTDeceIIED AGENT toutesEst VEAR gee pAv j

Coe8002NT AND EMPLANATION OF ANY WSOLATIONS ( Arterenre mil a##en 4. wars Arre)

Note -BOD Avg. quantity coltan represents % reduction.

NOTE - Avg. flow limitation = 0.20 MGD 45 nu/1 as a 7 day ave.

en. wives =A=u.

e s= s

=41 O=4a. cou.uv Aar

==.s suettu.TeOm cvevens (creas3

.,eapresse.

Ca** a== i' -

=8 pescHArics C romane cronT(para gm nas _ _ _GLN,_ _& _ _ENy._% _ _ _ _ _ _ _ _ _

(sv.

or.sn

,,,, g mamme_ _PSEgG_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _.

RT0005622

(

489

___ _ _ _P.9.i N 570_ _ _1_0c_ _ _ _ _ _ _ _ _ _

E es==eT aves.

l...C-a

..so.

i.___

_MbEBIL__

_tu_Q21Q1_______

s.o.(yo,no

,,,,oo

'.A G MI.Y _ SAT 7M CJWRATDE STATIN,,,,_ _ _ _ _ _,,,,,

,,A.

.g g,

,,g matATmt__I.O_E_lR_A_IJN_ _YS_(3tE_EK _ _- --

86 09 01 56 09 30

,,,,,,y,,

se0TE need tesmossems tiedese esepteens ein Assen.

( A Card Omer) ou A8JTeTV OA LOADefoe e8 Card 0e%)

OuhkeTV 04 COseCeasTRAftege pgggggggga (46JJ)

()d4fD

( AS=d$)

(d6JJ)

($def) ese. -,, - - -

=

A (8847)

AvsaAss es4 Bees use veseTo menseeves AvseAes esAssesses ussese g

g 00530 1

,,gg, ent.mn,

'ItymL m e A. u nessam ?

32.00 32.00 1

1/30 GR N

MVL nensue EFTHENP GROSS

          • essev 30.00**

100.00 1/30 GR 00340 1

mea.Auns e

u=====T 180.00 180.00 1

1/30 CR

_OE!MICAL OKYGEN DEMAND MVL i

EFTUENP GROSS 100.00 1/30 GR 1

00551 1

.esf.'u"e" s=T NOTE 2 NOTE 2 NOIE 2 PETBD El.M MYI' MILT i

HYDROCARBNS eeneser 10.00 15.nn 1/30 GR

!EFFuzWP G W l50050 1

me A.'u"."s 's=T N01E 1 gyni; 1 NME1 j pts MD romanes 1/30 GR; neewsamment

. EFTUENP GROSS 1

mea Auns 00400 uasmaaf 7.30 7.30 0

1/30 GR SU

pH pemeseY EETUENT GRCGS neeumessaer 6.00 9.00 1/30 GR I

e SAtePts sesAsupe=sNT 1

2

. esmaner i

esevenessant i

1 usa.Am.ns

. u sme=T i

commeT 1

asevenement or e seaws ss== tv s aansano Tm 3ayg I asaseg/TeTLs PeteeC6 PAL susCUTevs orrecem e.C.aeta v usso.a.m og smat t,a -v.e v4 tae seemt a

o =aven nue=nso was.eaggpnema.o onese am es,m em a

i-J. Treio o.='.a.a=5 accu.a"is -.a'ca t.en.m, a

'd.a.*:u=="e. *.*. o==a.o.=

g/ M stumJay OF ToeoEE seoiveDuats sanssonatsty mn g pgm Ops f

o==

e= a m '*

  • so us

..ea aan 4 top's""

ggg,pggggggpggghggggg,g 609 '339 N

86 10 24 Radiation Prot./Chesn. Mgr.

w.c===

==a**** <aa sue n e.: wo==aie

ar sa,er essenses one, eeranser swore as a. 3.ans Sf( SG WEC v es posbeute Or ases aaso _ - - aa est gggggg 3 3 u 6 C 4 e 3 e o ehasas re e.ede, aus

  • =d=****e*=*a**"'***=*****d**8**8=aa8****d*******

OrreCsA OS AufgeomeIse AGeBef Segessen vgas me p., y TVPSS 04 PasseTag Cateesses? A8e9 sEPLANATIO90 Oer ANY WeOLATeeses eRefereere enN essasshanessa here)

Notes Physical nrviification ed in order to obtain data.

489 is the Guard house yard drain neasurements are ob only when sappling protocols are met.

oc mM_ m o T che ca;a

V J

O PSEG m

%.,')

Pubhc Service F.lectric and Gas Company P O Box E Hancocks Bridge, New Jersey 08038 Salem Generating Station October 24, 1936 George Caporale - Chief Bureau of Permits Admin.

Division of Water Resources CN-029 Trenton, NJ 08625 Dear Mr. Caporale NEW JERSEY POLLUTANT DISCHARGE ELIMINATION SYSTEM DISCHARGE MONITORING REPORTS SALEM GENERATING STATION PERMIT NO.

NJ0005622 Attached is the Discharge Monitoring Report for Salem Generating Station containing the information as required in Permit No.

NJ0005622 for the month of September, 1986.

l l

This report is required by and prepared specifically for the Environmental Protection Agency ( EP A) and the New Jersey r~N Department of Environmental Protection ( NJDEP).

It presents only k,)

the observed results of measurements and analyses required to be performed by the above agencies.

The choice of the measurement i

devices and analytical methods is controlled by EPA and NJDEP, not by the company, and there are limitations on the accuracy of I

such measurement devices and analytical techniques even when used and maintained as required.

Accordingly, this report is not intended as an assertion that any instrument has measured, or any reading or analytical result represents, the true value with absolute accuracy, nor is it an endorsement of the suitability of any analytical or measurement procedure.

Exclusion explanations are included on additional pages.

l Very truly yours, fl

~.

l hemi s t ry/ Rad. Prot. Manager Salem Operations PDB: sig Attachments 1

l C

Executive Director, DRBC

/

Director. USNRC Office of Nuclear Reactor Regulation /

f Vice President - Nuclear j [f gy f

d, ph t

USEPA - Dr.

Richard Baker File:

NPDES.RPT I

ftA e

The Energy People n-

w NJPDES Report 10/24/86 Explanation of Exclusions September, 1986 m

('-}

The following exclusions are included in the attached report and explained below.

Exclusions have not endangered nor significantly impacted public health or the e nvi ro nme n t.

DMR NO.

EXPLANATION 484, 485 TRC - Chlorination rate reduced immediately to decrease TRC values.

48C Iron - Insufficient information available to determine the cause of the out-of-compliance value.

EH - Value exceeded when cooling water circulators were removed from service without realigning 48C discharge valves.

489 TSS. COD - These values may be the result of piping repairs being concluded at the time of sampling.

An investigation r~'

k,)s will be conducted if values continue to be high.

l t

1 I

l

<x I U

C NJPDES Report 10/24/86 j-Explanation of Doviations

(_

September, 1986

( )

The following explanations are included to clarify possible deviations from permit conditions.

General - The columns labeled, "No.

Ex.",

on the enclosed DMR, tabulate the number of daily discharge values outside the indicated limits.

Data reporting and accuracy reflect the working environment, the design capabilities and reliability of the monitoring instruments and operating equipment.

All reported concentrations are based on daily discharge values.

Total residual chlorine is performed once per eight hours of chlorination unless otherwise indicated.

Analytical values which are less than detectable are reported as zero unless o t he r wi s e indicated.

N/A indicates no chlorination occurred during the report period.

Analytical results for all parameters other than p H, temperature, TSS and TRC are provided by Century Laboratories ( NJDEP certification 03153).

(3

\\s l 48C Clarifier - Effluent pH is reported for informational purposes only.

487,489 - Measurements are obtained when sample acquisition proto cols are met.

No means is currently available for flow monitoring at these locations.

482,485 - Total residual chlorine values are normally unobtainable due to ongoing entrainment studies and the resultant equipment configuration.

Since all chemical treatments of or discharges to the circulating water system are common with at least one other discharge, those values are assumed to be identical for all parameters.

481-486 - Chlorination of the circulation water system normally does not occur except as otherwise noted.

Service water system chlorination is normally continuous and is monitored on the circulating water system outfall due to the inability to sample service water effluent directly.

Chlorination of both systems will be indicated by results reported for both and represents their combined affect upon the circulating water outfall.

..._- _.