ML20215K766
| ML20215K766 | |
| Person / Time | |
|---|---|
| Site: | 07109032 |
| Issue date: | 04/07/1987 |
| From: | Ordorica S M.M.P. QUALITY INSPECTIONS, INC. |
| To: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| References | |
| 28048, NUDOCS 8705110338 | |
| Download: ML20215K766 (1) | |
Text
-
7/- 903D.
Ulttuumic Slu>p & Field Inyttuna y
e Grunx County %nallupdintu j
MAUroCE MARSHALL PCKAfD g
'Q 17602 MARTHA AVENUE D
CErnf0S. CA 90701
. j-gN).h
. __20m6ans QUOlity InSPOClions p_
g gg,utAMRI.)
[
RETURN TO 396-SS 9
\\
4 Mr. Charles E.
MacDonald, Chief Transportation Branch Division of Materials and Fuel Cycle Facili.tg L,icensing Office of Nuclear Material Safety and Sa feg uarc3 s United States Nuclear Regul at ory Coranti ssion Washington, DC 20sss 37 ffR 10 Ao S
Dear Mr. MacDonald:
g g g.
In accordance with 10 CFR 71.12 (b) (1) (iii),
M.M.P.
QUALITY INSPECTIONS, INC., Radiographic niaterials license 4832-70 requests to be reuistered as a user of Tech / Ops Ident i ficat ion Nurnber USA /__SO3A___
Model
__h S_Q___ PackaDe B(U),
under terran of Cert ificate Cornpliance Nurnber
__9Q)_1____ revision __9__
issued to Technical Operations, Incorporated, Radiation Products Division, Burlington, Mannachusetts.
Sincerely, d*
i Wa ed Sal E.
Ordorica, Radiation Safety Officer M.M.P.
QUALITY INSPECTIONS, INC.
CN 0
00CKETEQ
,g\\
USNRQ 9]
APR 7198h) $2 fiVSS
- ' A!L SECT!04 IL=
L A L @fy l I
b COCKET CLERK 6.
L 9
Ai I ca
~~
8705110338 870410 PDR ADOCK 07109032
C FO T M 41 U.S. NUCLEAn REGULATORY COMMisSlot
' jG dN CERTIFICATE OF COMPLIANCE s., 'pd ?'.
FOR RADIOACTIVE MATEnlALS PACKAGES D # Css $lON NUU][H E FAC"$ AGE IDINilliCAllCN NUMDIR 0 PAGE NU'.90t it e TOT AL NUp.U [R PAGf f 's a Cg TissCAT[ Ngug(R 9032 4
USA /9032/B(U) 1 2
tk) P5<( AMBtl j
a Theb CettileCaf e is elluec to Ceehfy that the p3Caag.og and contents desCnl4J in llem 5 twlon ancels thc appbCable Saf et y Standa'OS ici f ortn en Title 10. Code of f eCeral Reg..latsor.1 Pa's II. EaChag'n; of Racioach.c Matenals foi transpoel ana Transportation of R *,oact.se MJter at Uncer Certa.n Conditions "
h Tr.85 CertshCale Coe$ not ret. eve the Con $'gnot f rom ComphanCe with any requisement of the regwtations of tne U S Department of Transportation or other D
h apphCADie segulatory agenCae1. enClod'ng the g3.ernment of any Cou ts) througn or into wh*Cn the pdChage will be transported n
3 TMi$ CE RllisC All I$'stsut D ON THE B A5:5 Of A SAf t T V AP.At ys 5 RE POAT OF THE *ACn AGE Dt 5sGN OA APPLIC Af 6ON a PREPAAED BY (Name saa aasress; b TsTLE AND :DLN1lfICAllON Os ntPOfil 054 APPLICATION in
$ Technical Operations, Inc.
Technical Operations, Inc. application p 40 North Avenue dated August 8, 1979.
[] Burlington,11A 01803 n9 C oOCart ~uutta 71-9032 h a CONDITIONS h
This Cert.t.Cate is Conditiona! upon fait.l!.ng the requirements of 10 CFR Part it. as apphCable, and the Conditions speCified below A';0 sj (a)
Pa ckaging
}
(1) flodel No.:
650 Le s
(2) Description taa N
A steel encased, uranium shielded, Iridium 192 source changer, j
Primary components consist of an outer steel shell, polyurethane potting material, uranium shield, Titanium "U" tube, and source
(
f holdown assembly.
The source holdown assembly secures the source (9
assembly in position within the crimped "U" tube.
Tamper-proof seal s y
and a padlock are provided on the packa(jing.
Total weight of the package is approximately 70 pounds.
!S
(
(3) Drawing is 10 The packaging is constructed in accordance with the Technical Oper-L(1 ations, Inc. Drawing No. 65002, Rev. A, Sheets 1, 2 and 3 of 3.
0 s
d s
Is iq.
r,-
2.
h a
s!
Al
+
'd
~
,?. !
R,.
- b /^
..j /
l4
^
.[/ -
g
.r.
4.'
4l 3'
4 N
d..
m, VEgipgrmm Camco'mm'rN m *MMMFFENh*M"N'"MMN"N
~
m m m r r r r m v v v1= W '
%9$$$$
k k b
5 m im Lv.
,UM a+
--==-:
CONDITSON s (connnucct)
Page 2 - Certificate No. 9032 - Revision No. 4 - Docket No. 71-9032 l
(b^
J 5.
(b) Contents i
59 i
(1) Type and fom of material f
i
']-
Iridium 192 as sealed sources which meet the requirements of special g
fom radioactive material.
{
3 59 (2) Maximun quantity of material per package 9j 240 curies
' 6.
The source shall be secured in the shielded position of the packaging by the source assembly.
The source assembly must be fabricated of materials capable of resisting a 1475'F fire environment for one-half hour and maintaining their I!.
positioning function.. The cable of the source assembly must engage the source p
holdown assembly.
The flexible cable of of the source assembly must be of (g
sufficient length and diameter to provide positive positioning of the source at q,
the crimp of the "U" tube.
3 h
7.
The nameplates shall be fabricated of materials. capable of resisting the fire 4
test of 10 CFR Part 71 and maintaining their legibil,ityv y,
'J 8.
The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR @71.12.
l (
/
~
- 9. 9.
Expiration date: June 30, 1989.
0
- G ff REFERENCN (m.9' Technical Operations, Inc. application dated August 8,1979.
l l
ld FOR THE U.S. NUCLEAR REGULATORY COMMISSION F6 s
d' d
l4 Charl s E. MacDonald, Chief
. Transportation Certification. Branch
}
Divi,sion of Fuel, Cycle and
,gt Ma'terial Safety,. N1SS' gi
.. dDate:
MId
~
~
(s
?.
r(
j ) ', y
,0!
.w
\\
,f i
,41
.4t t
(ht!)hNRll'L N a
JP '=' % if M.:E=i'EsT.
% %@gg
'r v =Jgp,;.7Jr TE.LL2'&'nw.LM.Wp 'c.lJE'pATmm'er-
- 1%.
{ ;*
3..
k' 4.
4 4
1
. DDCKEi NO.
l- __.h3>
j.
CONTROL Ho.
.hh W-DATE OF 000.
///2:d7M DATE RCVD.
8kdf f.
/_____.
FCUF pon _
FCAF LPDR -
l & E REF.
7 SAFEGL'ARDS _
FCTC _ V orncy DATE f f l lng;ca i
j.
1 i
s 4
1
, ~, -, -,,
,-r..
~
+