Download: ML20215K156 (1)


Text

v GPU Nuclear Corporation

~ '

g g{

Post Office Box 480 Route 441 South Middletown, Pennsylvania 17057-0191 717 944 7621 TELEX 84-2386 Writer's Direct Dial Number:

(717) 948-8461 4410-87-L-0051 Document ID 0136P April 29, 1987 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555

Dear Sirs:

Three Mile Island Nuclear Station, Unit 2 (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 Annual Update of the Defueling Water Cleanup System Technical Evaluation Report Pursuant to NRC Letter dated February 4, 1982, attached, for your information, is the annual update to the Technical Evaluation Report for the Defueling Water Cleanup System (DWCS).

This update primarily reflects previous NRC-approved system modifications (e.g.,

use of charcoal

filters, deep-suction, use of filters in series, use of modified knockout canisters as deep-bed filters).

Additionally, this revision updates the estimated man-rem exposure from DWCS operations.

Sincerely, V

,. R. Standerfer Director, TMI-2 FRS/RDW/eml Attachment cc: Regional Administrator, Region 1 - Mr. W. T. Russell Director, TMI-2 Cleanup Project Directorate - Dr. W. D. Travers 8705110098 870429 DR ADOCK 05000320 PDR GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation