ML20215G083

From kanterella
Jump to navigation Jump to search
Forwards AEOD/T611, Denied Access Due to Negative Room Pressure, Technical Review Rept.Licensee long-term Corrective Actions Adequate & Appropriate.Search for Similar Events of Denied Access Was Negative
ML20215G083
Person / Time
Site: Limerick 
Issue date: 12/19/1986
From: Cintula T
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
To: Rubin S
NRC OFFICE FOR ANALYSIS & EVALUATION OF OPERATIONAL DATA (AEOD)
Shared Package
ML20215G085 List:
References
AEOD-T611, NUDOCS 8612240270
Download: ML20215G083 (1)


Text

.__

co Mz-December 19, 1986 MEMORANDUM FOR: Stuart D. Rubin, Chief Reactor Operations Analysis Branch Office for Analysis and Evaluation AE0D/T611 of Operational Data THRU:

Patrick W. Baranowsky, Chief.

Reactor Systems Section 1 Reactor Operations Analysis Branch Office for Analysis and Evaluation of Operational Data FROM:

Theodore C. Cintula, Reactor Systems Engineer Reactor Systems Section 1 Reactor Operations Analysis Branch Office for Analysis and Evaluation of Operational Data

SUBJECT:

DENIED ACCESS DUE TO NEGATIVE ROOM PRESSURE Forwarded herewith is a copy of the subject AE0D technical review report. The investigation of this event of denied personnel access due to a negative room pressure.found:

1) The significant delay in gaining entry was due to a cognitive decision to address other problems at the plant. Subsequent entry to the room was achieved without undue time delays.
2) The licensee's long-term corrective actions were adequate and appropriate.

A search for similar events of denied access was negative. Therefore, this report finalizes and concludes the investigation of this event.

Theodore C. Cintula, Reactor Systems Engineer Reactor Systems Section 1 Reactor Operations Analysis Branch Office for Analysis and Evaluation of Operational Data cc w/ enclosure:

DISTRIBUTION:

J. Heltemes, AE0D M. Beaumont, W W

SRubin F. Hebdon, AE0D C. Brinkman, CE ROAB C/F KBlack J. Crooks, PTB R. Borsum, B&W TCintula MWilliams S. Massaro, PTS L. Gifford, GE PBaranowsky WLanning AE00 S/F JSniezek, DEDR0GR

\\

n OFC

ROAB S
ROAB:BC

_____:_____f_ g :ROAl NAME :TCintula:nc :PBaranowsky :SRubin s

p DATE:12/17/86

12/l6/86
12/l9/86 I

0FFICIAL RECORD COPY S

-