ML20215F468

From kanterella
Jump to navigation Jump to search
Advises That One Insp Finding Involved Unretrievable Radiographic Film,Per Util 860124 Response to Const Appraisal Team Insp Rept.Westinghouse Developed Action Plan to Account for Mislocated Radiographs
ML20215F468
Person / Time
Site: Byron 
Issue date: 09/26/1986
From: Ainger K
COMMONWEALTH EDISON CO.
To: James Keppler
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
NUDOCS 8610160225
Download: ML20215F468 (1)


Text

_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - - _ _

'm\\

_ } Commonwealth Edison i

72 West Adams Street, Chicago. Illinois v/ Address Reply to: Post GSce Box 767 Chicago, Illinois 60690 - 0767 September 26, 1986 Mr. James G. Keppler Regional Administrator U.S. Nuclear Regulatory Commission Region III

~199 Rcosevelt Road Glen Ellyn, IL 60137

Subject:

Byron Station Unit 2 l

NRC Cat Inspection NRC Docket No. 50-455 Reference (a): January 24, 1986 letter from D. L. Farrar to J. G. Keppler

Dear Mr. Keppler:

Reference (a) provided Commonwealth Edison's response to the inspection report of the NRC Construction Appraisal Team (CAT). One of the inspection findings involved radiographic film which was not retrievable.

The radiographic films are for components supplied by Westinghouse.

In response to this CAT inspection finding, Commonwealth Edison's Quality Assurance Department has been auditing Westinghouse for radiograph retrievability. As a result of this audit effort, it has become apparent that some additional radiographs may be mislocated. Westinghouse has developed an action plan to account for these radiographs. We will inform l

you of the results of their efforts by October 15, 198,6.

Please direct any questions regarding this matter to this office.

Very truly yours, K. A. Ainger Nuclear Licensing Administrator 1m 861016022S 860926 PDR ADOCK 05000455 2170K PDR SEP 3 01986 Leot

-- ---- --