'm\\
_ } Commonwealth Edison i
72 West Adams Street, Chicago. Illinois v/ Address Reply to: Post GSce Box 767 Chicago, Illinois 60690 - 0767 September 26, 1986 Mr. James G. Keppler Regional Administrator U.S. Nuclear Regulatory Commission Region III
~199 Rcosevelt Road Glen Ellyn, IL 60137
Subject:
Byron Station Unit 2 l
NRC Cat Inspection NRC Docket No. 50-455 Reference (a): January 24, 1986 letter from D. L. Farrar to J. G. Keppler
Dear Mr. Keppler:
Reference (a) provided Commonwealth Edison's response to the inspection report of the NRC Construction Appraisal Team (CAT). One of the inspection findings involved radiographic film which was not retrievable.
The radiographic films are for components supplied by Westinghouse.
In response to this CAT inspection finding, Commonwealth Edison's Quality Assurance Department has been auditing Westinghouse for radiograph retrievability. As a result of this audit effort, it has become apparent that some additional radiographs may be mislocated. Westinghouse has developed an action plan to account for these radiographs. We will inform l
you of the results of their efforts by October 15, 198,6.
Please direct any questions regarding this matter to this office.
Very truly yours, K. A. Ainger Nuclear Licensing Administrator 1m 861016022S 860926 PDR ADOCK 05000455 2170K PDR SEP 3 01986 Leot
-- ---- --