Forwards Proposed Rev to FSAR Table 14.2-89, 50% Load Reduction, Modifying Test to Permit Performance at 100% Reactor Power Only & Allowing Minimal Manual Intervention to Bring Plant Conditions to Steady State,For Concurrence
ML20215E380
Person / Time
Site: Byron, Braidwood, 05000000
Issue date: 12/11/1986
From: Ainger K
COMMONWEALTH EDISON CO.
To: Harold Denton
Office of Nuclear Reactor Regulation
References
2444K, NUDOCS 8612220246
Download: ML20215E380 (2)


Text

.

/

h CORMRORWealth h

' One Fwst Nebonel Plaza, CNcego, Illinois j\\~

Address Reply to: Post Omco Box 767 g

CNoa00. lilinois 60600 0767 December 11, 1986 Mr. Harold R. Denton, Director Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, DC. 20555

Subject:

Byron Station Unit 2 Braidwood Station Units 1 and 2 Initial Test Program NRC Docket Nos. 50-4'55, 50-456 & 50-457

Dear Mr. Denton:

This letter contains a proposed revision to a startup test included in the Initial Test program. The specific test, 50% load reduction, is described in FSAR Table 14.2-89.

The test is being modified so it will only be performed at 100% reactor power. Additionally, the acceptance criteria of the test is being modified to allow some minimal manual intervention to i

bring plant conditions to steady state following the load reduction.

Attachment A of this letter contains the proposed ravision to the FSAR Chapter 14 test abstract.

We believe this proposed change is consistent with current test methods on other Westinghouse plants where the test is performed only at one power level. In addition, we believe some manual intervention is acceptable and should not invalidate the test results if operating procedures call for manual control of a system to recover from the transient.

We are requesting NRC concurrence with this proposed change to the Initial-Test program for Byron Unit 2 and Braidwood. The attached FSAR revision will be included in the next amendment if the proposed change is approved.

please direct any questions regarding this matter to this office.

One signed original and fifteen copies of this letter and attachment are provided for NRC review.

Very truly yours, Kd K. A. Ainger Nuclear Licensing Administrator

/klj cc: Resident Inspector - Byron Resident Inspector - Braidwood Attachmen' 8612220246 861211 h

R ADOCK 05000455 ffS PDR 4V 2444K g

/

\\

,4 77ACHMEA! Y A B/B-FSAR

's i';

TABLE 14.2-89 50% LOAD REDUCTION 5*

(Startup Test)

Plant Condition or Prerequisites Reactor power will be at h 100%.

Test Objective To demonstrate manual and.- automatic.. plant response to a 50% step load reduction. q.,

Test Summary Demonstrate plant response to nL50% step load reduction from~3DDaunt 100% reactor power.

With plant systems in their automatic modes of control, the 50% load reduction is-initiated from the't6rbine control panel.

i Acceptance Crite'ria' a.

Reactor and turbine'do not trip.

. b.- Unacceptable levels of water hammer will not occur in the steam generator or feedwater system due to the 50%

load rejection.

c.

Steam generator safety valves will not lift.

d.

Pressurizer safety valves will not lift.

' Soue "inimal may e.

Jan manual intervention d' be required to bring plant conditions to steady state.

t w

14.2-101

..