A OPERATING DATA REPORT Docket No.:

50-309 Date:

01/Aug/86 Completed By:

Steven L Jacobs 1

Telephone:

207-882-6321

1. Unit Name.......................................

Maine Yankee

2. Reporting Period................................

July 1986

3. Licensed Thermal Power (MWt)....................

2630 4.

Nameplate Rating (Gross MWe)....................

864 5.

Design Electrical Rating (Net MWe)..............

825 6.

Maximum Dependable Capacity (Gross MWe).........

850 7.

Maximum Dependable Capacity (Net MWe)...........

810 8.

If Changes in Capacity Ratings (Items Number 3-7)

Since Last Report, Give Reasons:

NO CHANGES

9. Power Level to Which Restricted, if Any (Net MWe)

NO RESTRICTIONS

10. Reasons for Restrictions, if Any:

THIS MONTH YEAR-TO-DATE CUMULATIVE

11. Hours In Reporting Period 744.00 5.087.00
12. Number of Hours Reactor Was Critical...........

320.08 4.169.94 96.507.66

13. Reactor Reserve Shutdown Hours..................

0.00 0.00 0.00

14. Hours Generator On-line..

304.30 4.085.06 93.729.72

15. Unit Reserve Shutdown Hours..................

0.00 0.00 0.00

16. Gross Thermal Energy Generated (MWH)........

724.170.00 9.972.953.00 211.973.634.00

17. Gross Electrical Energy Generated (MWH)........

240.350.00 3.352.660.00 69.592.380.00

18. Net Electrical Energy Generated (MWH)........

232.241.00 3.233.728.00 66.420.043.00

19. Unit Service Factor......

40.90 80.30 77.90

20. Unit Availabilty Factor..

40.90 80.30 78.67

21. Unit Capacity Factor (Using MDC Net)........

38.54 78.48 69.93

22. Unit Capacity Factor (Using DER Net)........

37.84 77.05 68.09 --

23. Unit Forced Outage Rate..

0.00 2.19 6.67

24. Shutdowns Scheduled Over Next 6 Months:

NONE

25. If Shutdown at End of Report Period, Estimated Date of Startup:

N/A 8610140385 860731 PDR ADOCK 05000309 g

5 g

.'N Docket No.:

50-309 Unit Name:

Maine Yankee Date:

August 1,1986 Completed By:

J. M. Taylor Telephone:

882-6321 REPORT MONTH:

July 1986 NARRATIVE

SUMMARY

OF OPERATING EXPERIENCES At the beginning of the month, the plant was shutdown. At this time, a new type rupture disk mechanism was installed in the EFCV air cylinders, and the condenser and #2 LP turbine were inspected.

On 18 July, the reactor was made critical.

On 19 July, the unit was phased to the grid and power held at 30% for S/G boron soak.

On 20 July, power was increased to and maintained at 75% for mussel control.

On 21 July, power was raised to 90%.

On 22 July, power was raised to 96%.

On 24 July, power was increased to 98%.

On 30 July, power was increased to 99% using steam flow calorimetric due to fouling of feed flow venturi.

Power remained at 99% for the remainder of the month.

+

0227N

,. N.

AVERAGE DAILY UNIT POWER LEVEL FOR JULY 1986 Docket No.:

50-309 Unit:

Maine Yankee Date:

01/Aug/86 Completed By:

Steven L Jacobs Telephone:

207-882-6321 Day Avg. Daily Power Level Day Avg. Daily Power Level (MWe-Net)

(MWe-Net) 1 O

16 O

2 O

17 O

3 O

18 O

4 O

19 130 5

O 20 528 6

O 21 739 7

O 22 795 8

O 23 818 9

O 24 932 10 O

25 831 11 O

26 833 12 O

27 831 13 O

28 831 14 O

29 830 15 O

30 832 31 846

,._s,-_m,,._

_-.-_y---

7 7

y y

m w---

ek

.s UNIT SHUTDOWNS AND POWER REDUCTIONS Docket No.:

50-309 FDR JULY 1986 Unit:

Maine Yankee Date:

01/Aug/86 Completed By:

Steven L Jacobs Telephone:

207-882-6321 Page:

1 of 1 Number 12-86-9 Dato 860630 Typa (1)

S Durction (Hours) 439.7 Roccon (2)

B Method (3) 1 LER O N/A Sy2 tem Coda (4)

CD Component Cada (5)

VALVEX-D Maintenance outage to repair EFCV air cylinders and to inspect condenser.

Ccuse and Installed new type Corrective rupture disk Action assembly in EFCV air cylinders.

Inspected condenser and LP turbine.

2. REASON: (cont)
4. SYSTEM CODE:-
1. TYPE:

(F)orced F-Administrative Exhibit G-Instructions (S)cheduled G-Operational Errcr for Preparation of Data

~

H-Other (Explain)

Entry Sheets for Licensee Event Report

2. REASON A-Equipment Failure
3. METHOD:

(LER) File (NUREG.0161)

B-Maintenance or Test 1-Manual C-Refueling 2-Manual Scram 5.

COMPONENT CODE:

D-Ragulatory Restriction 3-Automatic Scram Exhibit I-Same source E-Operator Training te 4-Other (Explain) as above.

License Examination

O MAIRE HARHEE 'ATOMICPOWERComPARUe

,uaug,ay,?n"gC,"2s h

(207) 623-3521 be l

l l

August 7, 1986 l

HN-86-102 GDH-86-185 l

Office of Resource Management United States Nuclear Regulatory Commission Hashington, D. C.

20555 Attention:

Mr. Richard A. Hartfield, Chief Management Information Branch

References:

(a) License No. DPR-36 (Docket No. 50-309)

(b) NUREG-0020, Licensed Operating Reactors Status Summary Report

Subject:

Haine Yankee Monthly Statistical Report Gentlemen:

Enclosed you will find the Monthly Statistical Report for the Maine Yankee Atomic Power Station for July, 1986.

l Very truly yours, HAINE YANKEE ATOMIC POWER COMPANY h&

G. D. Whittier, Manager Nuclear Engineering and Licensing GDH/bjp l

Enclosure cc: Mr. Ashok C. Thadani Dr. Thomas E. Hurley

/

Mr. Pat Sears 4 6 Hr. Cornelius F. Holden Mr. Lloyd Savage

/