October 8, 1986 Docket No.: 99900302 Mr. William Van Meter 1311 N. "L" Street Lake Worth, FL 33460

Dear Mr. Van Meter:

Enclosed please find a copy of Inspection Report No. 99900302/86-01. The report

' covers the NRC inspection conducted at Western Piping and Engineering on August 11-12, 1986. The inspection was conducted to address your concerns with the qualifi-cations of the engineer that performed certifications of pipe clamps manufactured by Western Piping and Engineering as you stated in a letter to Chairman Palladino on March 29, 1986.

If you have any questions, please contact us.

Sincerely.

Original signed by Robert, Heishnam Robert F. Heishman, Chief Vendor Program Branch Division of Quality Assurance, Vendor, and Technical Training Center Programs Office of Inspection and Enforcement

Enclosure:

As stated Distribution wfo enc.losure, tw 4

QAVT Reading VPB Reading RStarostecki BKGrimes HMiller JCraig RCorreia RHeishman VP T

fDQAVT

Q RC JCraig RFHeishmars 10/(, /86

,10/f,/86 10/0$/86 8610140276 861008 I

PDR GA999 EECWESTP tj0 99900302 PDR