METROPOLITAN EDISON COMPANY JERSEY CENTRAL POWER AND LIGHT COMPANY PENNSYLVANIA ELECTRIC COMPANY GPU NUCLEAR CORPORATION DOCKET NO. 50-289 THREE MILE ISLAND NUCLEAR STATION, UNIT NO. 1 AMENDMENT TO FACILITY OPERATING LICENSE Amendment No.121 License No. DPR-50 1.
The Nuclear Regulatory Comission (the Commission) has found that:
A.
The application for amendment by GPU Nuclear Corporation, et al.
(the licensees) dated June 26, 1986, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Commission; C.
There is reasonable assurance (i) that the activities authorized
-by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and
. E.x The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
gno28eR*n8){gi P
. 2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.c.(2) of Facility Operating License No. DPR-50 is hereby amended to read as follows:
Technical Specifications TheTechnicalSpecificationscontainedit[ Appendix A, as revised through Amendment No.121, are,
hereby incorporated in the license. GPU Nuclear Corporation shall operate the facility in accordance with the Technical Specifications.
3.
This license amendment is effective as of its date of issuance.
FOR THE NUCLEAR REGULATORY COMMISSION John F. Stolz, Directo PWR Project Directorate #6 Division of PWR Licensing-B
Attachment:
Changes to the Technical Specifications Date of Issuance: October 1,1986
_-..e..,
ATTACHMENT TO LICENSE AMENDMENT N0.121 FACILITY OPERATING LICENSE NO. DPR-50 DOCKET N0. 50-289 Replace the following page of the Appendix "A" Technical Specifications with the attached page. The revised page is identified by Amendment number and contains'a vertical line indicating the area of change.
Remove Insert 3-87a 3-87a 1
I
s I
TABLE 3.18-1 FIRE DETECTION INSTRUMENTS Total Number Instrumen'; Location of Detectors Minimum Instruments Operable Heat Smoke Heat Smoke 9.
Auxiliary Bldg. Elev. 271' Heat Exchanger Vault (Zone 11) 0 10 NA 5
- 10. Auxiliary Bldg. Elev. 281' Pipe Penetration Area (Zone 1) 0 5
NA 3
Makeup & Purification Pumps 0
3 NA 2
(Zone 2)
Valve Gallery (Zone 3) 0 1
NA 1
Cable Gallery (Zone 4) 0 3
NA 2
l Hallway (Zone 10) 0 7
NA 4
- 11. Auxiliary Bldg. Elev. 305' Decay Heat & Nucl. Service Pumps & MCC 1 A,1B (Zone 5) 0 7
NA 4
Ventilation Room 1
1 1
1
- 12. Intermediate Bldg. Elev. 295' EF-P-2 AaB Rooms (Zone 1) 0 6
NA 3
Cable Area (Zone 2) 0 2
NA 1
EF-P-1 Room (Zone 3) 0 2
NA 1
Valve Gallery (Zone 4) 0 2
NA 1
13.
Intermediate Bldg. Elev. 305' Tank Room (Zone 5) 0 1
NA 1
- 14. Reactor Bl dg. Elev. 281
Exhaust Ducts (Zone 1) 0 3
NA 2
Decay Heat Valve 1 (Zone 2) 0 1
NA 1
Decay Heat Valve 2 (Zone 2) 0 1
NA 1
Cable Tray at Let Down 0
1 NA 1
Cooler (Zone 3)
- 15. Reactor Bldg. Elev. 305' Exhaust Ducts (Zone 4) 0 5
NA 3
Purge Exhaust (Zone 5) 0 1
NA 1
Cable Tray at Personnel 0
2 NA 1
Hatch (Zone 6) 16.
Reactor Bldg. Elev. 346' D-Ring ld (Zone 7) 0 6
NA 4
0-Ring le (Zone 8) 0 6
NA 4
- 17. Reactor Bldg. Elev. 382' Cable Tray (Zone 9) 0 2
NA 1
18.
Reactor Bldg. Elev. 382' Elevator Room (Zone 10) 0 1
NA 1
Amendment No. pff, % 121 3-87a
-..