Text
__
N'.
p_. f/g HITTMAN MMW IQ 396-55' 1256 N. CHURCH STREET l
NUCLEAR MOORESTOWN, NJ 08057 l
l
}b l
J (609) 722-5700
{
l l
1 l
leg--- 3p O-bSN
'67 JJa -1 !J1 $l Remitter 3O14.A Ch ad fl 7. MM -. - --- -------
l l
May 26, NEi O g "-~~-~~~'~
T c cl b N5b crtecH y~W Lk. &{ >1---.
'M i; l
1
. g *4. u" ~ ~ ~G~
1~~~
i Transportation Certification Branch '87 JW ~2 g g D--- }Tip
'j]-~
Mr. Charles E.
MacDonald, Chief l
U.S.
Nuclear Regulatory Commission se I
Washington, DC 20555 e-p0Cmro
~
USNRC t c fi
?.
l
SUBJECT:
RENEWAL OF CERTIFICATION JUN 11987 ) ~I2 WESTINGHOUSE HITTMAN NUCLEAR INCORPORATED HN-100 SERIES 3 SHIPPING CASK ng33
~
I 9
UAIL *ECTICH 8 % W ELERK
/
REFERENCE:
Certificate of Compliance No. 9151 (N
i g
(s\\
N l
Dear Mr. MacDonald:
N (o I
l l\\
It is requested that the referenced Certificate of Compliance be j
renewed.
Enclosed are eight (8) copies of the following Westinghouse l
Hittman Nuclear Incorporated documents for your review:
" Safety Analysis Report for the HN-100 Series 3 Raowaste Shipping i
f Cask", Hittman Document No. STD-R-02-OOi, Rev.
9*.
)
.i Hittman HN-100 Series 3 Cask Certification Drawing Nos. :
1 COO 1-5-9138, Rev. 11*
COO 1-5-9143, Rev. 8 COO 1-5-9139, Rev. 8 COO 1-5-9144, Rev. 3 COO 1-5-9140, Rev. 8 STD-02-035, Rev. A COO 1-5-9141, Rev. 3 STD-02-036, Rev. A COO 1-5-9142, Rev. 1 STD-02-037, Rev. 2 With the exception of the two (2) asterisked documents, all of the listed documents have been previously submitted to and reviewed by you at the revision level indicated.
l The Safety Analysis Report for the HN-100 Series 3 Cask, Hittman l
Document No. STD-R-02-OOi, has been primarily revised for clarity and l
to remove typographical errors.
In addition the SAR has also been revised to reflect the proper size of the primary lid gasket seal.
Hittman Drawing No.
COO 1-5-9138 has been revised to include a
reference to the current cask handling procedure.
The Bill of Materials and Section B-B on this drawing have also been revised to l
l reflect primary and secondary lid seal gaskets which are more detailed and in full agreement with the Safety Analysis Report.
8706170028 870526 PDR ADOCK 07109151 jf g C
$$$$$Q$@?@@d$$$56@p{@jpggggggggg
I u
A.
}
Mr. Charles E.
MacDonald, Chief May 26, 1987 Page 2 The current Certificate of Compliance expires on June 30, 1987.
It is requested that this Certificate of Compliance be extended, as
- required, to permit your review of this consolidated application for renewal.
Enclosed please find a
check in the amount of $150 for fees associated with processing this renewal application for the Certificate of Compliance.
1 It is noted that the attached documents are stamped " Proprietary" and bear notices relative to the further dissemination and use of this information.
Hittman has no objection to the filing of this material in the Nuclear Regulatory Commission Public Document Room, provided that the notices remain on file with this material.
Very truly yours, Bryan A.
Roy Manager, Design and 3
Process Engineering DW/raj j
Enclosures As Stated cc:
D.
R.
Neely
)
D.
Wozniak j
P.
A.
Walsh D.
Dimmick B.
R.
Sewter i
j C:MM/28
l]l 4.-
. j, e
lg r-s
- - (3-
'l
.c' d'
.w i
i
'8.
g' '
.i
.)
'd l '"
J xv
.i DOCKET NO.I
[+k/[/
-CONTROL tio.'
NAf
.DATE Of D00.
6/Md7 DATE RCVD.
M//g7,
_ ag _
l/
FCUF_
p FCAF_
-Lppg 1 & E REF, -
SAFEGUARDSi FCIC OTliER DATEM
(('lt/JnAt 9
i I
d
<-