ML20214U197
| ML20214U197 | |
| Person / Time | |
|---|---|
| Site: | Limerick |
| Issue date: | 06/02/1987 |
| From: | Butler W Office of Nuclear Reactor Regulation |
| To: | |
| Shared Package | |
| ML20214U200 | List: |
| References | |
| NUDOCS 8706110089 | |
| Download: ML20214U197 (5) | |
Text
.
!e asog#o,,
UNITED STATES 8
~
NUCLEAR REGULATORY COMMISSION o
g j
WASHINGTON, D. C. 20555
%,...../
P_HILADELPHIA ELECTRIC COMPANY DOCKET NG. 50-352 LIMERICK GENERATING STATION, UNIT 1-AMENDMENT TO FACILITY OPERATING LICENSE Amendment No. 5 License No. NPF-39 1.
The Nuclear Regulatory Comission (the Comission) has found that A.
The application for amendment by Philadelphia Electric Company (the licensee) dated January 30, 1987, as supplemented on March 27 and May 13 and 20, 1987, complies with the standards and requirements of the Atomic Energy Act of 1954, as amended (the Act), and the -
Commission's rules and regulations set forth in 10 CFR Chapter I; B.
The facility will operate in conformity with the application, the provisions of the Act, and the rules and regulations of the Comission; C.
There is reasonable assurance (i) that the activities authorized by this amendment can be conducted without endangering the health and safety of the public, and (ii) that such activities will be conducted in compliance with the Comission's regulations; D.
The issuance of this amendment will not be inimical to the common defense and security or to the health and safety of the public; and E.
The issuance of this amendment is in accordance with 10 CFR Part 51 of the Commission's regulations and all applicable requirements have been satisfied.
2.
Accordingly, the license is amended by changes to the Technical Specifications as indicated in the attachment to this license amendment, and paragraph 2.C.(2) of Facility Operating License No. NPF-39 is hereby amended to read as follows:
Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 5
, are hereby incorporated into this license.
Philadelphia Electric Company shall operate the facility fr. accordance with the Technical Specifications and the Environmental Protection Plan.
i P
t '
. 3.
This license amendment is effective as of its dan of isstance.
FOR THE NUCLEAR REGUI ATORY COMMISSION Walter R. Butler, Director Project Directorate I-2 Division of Reactor Pro.iects
Attachment:
Changes to the Technical Specifications j
Date of Issuance: June 2, 1987 J
t v
5
ATTACHMENT TO LICENSE AMENDMENT NO. 5 FACILITY OPERATING LICENSE NO. NPF-39 DOCKET NO. 50-352 Replace the following pages of the Appendix "A" Technical-Specifications with the attached pages. The revised pages are identified by Amendment number and contain vertical lines indicating the area of change. Overleaf page provided to maintain document corapleteness.*
I Remove Insert 3/4 7-7 3/4 7-7 3/4 7-8*
3/4 7-8*
i l
i
PLANT SYSTEMS a
SURVEILLANCE REQUIREMENTS (Continued) 2.
Verifying within 31 days after removal that a laboratory analysis of a representative carbon sample.obtained in accordance with Regulatory Position C.6.b of Regulatory Guide 1.52, Revision 2, March 1978, meets the laboratory testing criteria of Regulatory Dosition C.6.a of Regulatory Guide 1.52, Revision 2, March 1978, for a methyl iodide penetration of less than 1%; and 3.
Verifying a subsystem flow rate of 3000 cfm + 10% during subsystem operation when tested in accordance with ANSI N510-1980.
d.
After every 720 hours0.00833 days <br />0.2 hours <br />0.00119 weeks <br />2.7396e-4 months <br /> of charcoal adsorber operation by verifying within 31 days after removal that a laboratory analysis of a repre-sentative carbon sample obtained in accordance with Regulatory Position C.6.b of Regulatory Guide 1.52, Revision 2, March 1978, meets the laboratory testing criteria of Regulatory Position C.6.a of Regulatory Guide 1.52, Revision 2, March 1978, for a methyl iodide penetration of less than 1%.
At least once per 18 months by:
e.
1.
Verifying that the pressure drop across the combined prefilter, upstream and downstream HEPA filters, and charcoal adsorber banks is less than 6 inches water gauge wnile operating the subsystem at a flow rate of 3000 cfm + 10%; verifying that the prefilter pressure drop is less thar. D.8 inch water gauge and that the pressure drop across each HEPA is less than 2 inches water gauge.
2.
Verifying that on each of the below chlorine isolation mode actuation test signals, the subsystem automatically switches to the chlorine isolation mode of operation and the isolation valves close within 5 seconds:
a)
Outside air intake high chlorine, and b)
Manual initiation from the control room.
3.
Verifying that on each of the below radiation isolation mode actuation test signals, the subsystem automatically switches to the radiation isolation mode of operation and the control room is maintained at a positive pressure of at least 1/8 inch water gauge relative to the turbine enclosure and auxiliary equipment room and outside atmosphere during subsystem operation wit air flow rate less than or eoual to 525* cfm:
a)
Outside air intake high radiation, and b)
Manual initiation from control room.
- An allowable outdoor airflow rate of less than or equal to 2100 cfm is per-missible until the issuance of the Unit 2 full power operating license.
LIMERICK - UNIT 1 3/4 7-7 Amendment No. 5
PLANT SYSTEMS 1
SURVEILLANCE REQUIREMENTS (Continued) 4 f.
After each complete or partial replacement of a HEPA filter bank by i
verifying that the HEPA filter bank satisfies the inplace penetra-tion and hypass leakage testing acceptance criteria of less than 0.05%
in accordance with ANSI N510-1980 while operating the system at a flow rate of 3000 cfm i 10L g.
After each complete or partial replacement of a charcoal adsorber bank by verifying that the charcoal adsorber bank satisfies the inplace penetration and bypass leakage testing acceptance criteria of less than 0.05% in accordance with ANSI N510-1980 for a halogenated hydrocarbon refrigerant test gas while operating the system at a flow rate of 3000 cfm i 10L 4
)
3 i
LIMERICK - UNIT 1 3/4 7 '
_.. _. _ - _ _.. - _ _.,, - _ _. _ _..