fa

/NEA Idaho NationalEngineedng Laboratory March 9, 1987 Mr. M. Carrington, Program Manager Office of Nuclear Reactor Regulation U.S. Nuclear Regulatory Commission Washington, D.C.

20555 TRANSMITTAL OF " DRAFT TECHNICAL EVALUATION REPORT, REVIEW 0F SOUTH TEXAS PROJECT QUALITY DATA PROCESSING SYSTEM RELIABILITY STUDY" EGG-REQ-7542, FEBRUARY 1987 (FIN D6019) - EWR-38-87 Ref: FIN No. D6019 - Technical Assistance For Casework Reviews

Dear Mr. Carrington:

Transmitted herewith is the above subject draft TER.

This TER documents EG&G Idaho's evaluation of a Westinghouse submittal regarding the reliability of the South Texas Project (STP) Qualified Data Processing System (QDPS).

It is our conclusion that the QDPS digital channels have an estimated higher availability than comparable analog channels.

Very truly yours, m

0 E. W. Roberts NRC Headquarters Support 9P

Enclosure:

8703 g60$hO 0500 As Stated PD

^

cc:

G. L. Jones, DOE-ID J. L. Mauck, NRR-PAEI (2)

F. Rosa, NRR-PAEI (w/o Encl.)

S. Weiss, NRR-PAEI J. O. Zane, EG&G Idaho, Inc. (w/o Encl.)

[EGzGu.~.

1142s nockvitse rike suite tro acckv111e, no 20es2