ML20214Q993

From kanterella
Jump to navigation Jump to search

Forwards Presentation Slides & Attendance List from Commissioner Fm Bernthal & Assistant Jf Meyer 870519 Visit to Facility for Meeting & Plant Tour
ML20214Q993
Person / Time
Site: Cooper 
Issue date: 06/01/1987
From: Long W
Office of Nuclear Reactor Regulation
To: Calvo J
Office of Nuclear Reactor Regulation
References
TAC-65409, NUDOCS 8706050288
Download: ML20214Q993 (15)


Text

{{#Wiki_filter:, ,Iune.1, 1987 Docket No. 50-298 MEMORANDUM FOR: Jose A'. Calvo, Chief ProjectDirectorate-_IV Division of Reactor Projects, III, IV, V and Special Projects FROM: William Long, Project Manager Project Directorate - IV DivisionofReactorProjects,III, IV, V and Special Projects

SUBJECT:

VISIT OF COMMISSIONER BERNTHAL'TO COOPER NUCLEAR STATION [ On May-19, 1987, Commissioner F. M..Bernthal and his assistant J.F. Meyer visited the Cooper Nuclear Station for a meeting and plant tour. Copies of the attendance list and presentation slides are enclosed for your information. @ {sig$ id W William 0. Long, Project Manager ProjectDirectorate-IV Division of Reactor Projects - III, IV, V and Special Projects

Enclosures:

As stated DISTRIBUTION -Mi NRC PDR Local PDR PD4 Reading WLong PNoonan D. Dubois J. Gagliardo R. Hall J. Meyer F. Schroeder D. Crutchfield F. Miraglia C. Miller J. Sneizek J. Taylor T. Murley R. Martin V. Stello PD4 WLona:as_ sr -l' I 8706050288 870601 1 PDR ADOCK 05000299 4 p PDR

ENCLOSURE 1 COMMISSICNER BERNTHAL MEETING ATTENDEES NRC Washington, D.C. - Frederick Bernthal, Commissioner Jim Meyer, Staff Assistant NRC/NRR - W. Long NRC Region IV - Ray. Hall John Jaudon NRC Site Resident Inspectors - Dennis DuBois Elden Plettner Board of Directors - Fred Harrington Ralph Johnson Iowa Power and Light - Jim Bull NPPD - Don Schaufelberger - President and Chief Executive Officer Hugh Parris - Special Assistant to the President Larry Kunci - Vice President - Nuclear George Trevors - Division Manager for Nuclear Support Bob Wilbur - Division Manager of Nuclear Engineering and Construction Vern Wolstenholm - Division Manager of Quality Assurance Dave Whitman - Program Control Manager Guy Horn - Division Manager for Operations Jim Dutton - Nuclear Training Manager Sam Peterson - Plant Services Manager (Acting) Garret Smith - Quality Assurance Manager (Site) Bob Jansky - Outage Coordinator Kim Walden - Manager Nuclear Licensing and Safety

ENCLOSURE 2 NEBRASKA PUBLIC POWER DISTRICT BOARD OF DIRECTORS Nuclear Power Group PRESIDENT VICE - PRESIDENT NUCLEAR DIVISION MANAGER NUCLEAR SUPPORT - Training Licensing Overview of Nuclear Activities Interface With Outside Groups l I DIVISION MANAGER DIVISION MANAGER DIV!SION MANAGER ENGINEERING AND NUCLEAR OPERATIONS OUALITY ASSURANCE CONSTRUCTION - Design Engineering PROGRAM CONTROL Operations - Site MANAGER -Engineering GeneralOffice Projects Construction - Maintenance vendor Audits Budgeting Configuration Management - Radiological Planning Design Basis Verification - Security Policies & Procedures Fuel - Material Control Program Maintenance - Administration l Financial Analysis

1 ~ Nuclear Power Group I I Employment (Full Time Employees) 500 -- 467 450 -- 415 l 400 -- 350 -- 300 -- 284 y 1983 1984 1985 1986 1987 1988 l*

  • 5 Site O G.O.

E Total l Annual Levels as of March 1 i

COOPER NUCLEAR STATION Operation and Maintonaco Expense Less Fuel 55-50-5 I. i ' f Q, ;;. w' 4, 35 s, gk ?: ' N

c. c z, 3 ph 15 p

y 1979 1980 1981 1982 198 1984 1985 1986 1987* 1988*

COOPER NUCLEAR STATION Capital Exp:nditura ?M8 ci.~-.., h:.':, >: -[.NQ {' :. p:. 40 N:h.' 4 t:. 3 h.: ~l F: 35 f;' > )' f::: i:. 'Ji F:.:: 2:'.4 K: 30 F:::. 1 t: :.':S p: >: X 'J: k $ k' 25- .l f:'.. 5: s f::: k t t: N, 20-E: ':'d h:::M

~.3

[' f; 15 f'. !'N f: /. W F.. x ::: 14 [: s l[J [: 10 t: l ,, h: ' M '(:.., k. F:: I s' p::: ) s c Nls ', ~ 5- -t-c. .s 0 1979 1980 1981 1982 1983 1984 1985 1988 1987* 1988* Year vettmatn

MAJOR FACILITY IMPROVEMENTS COMPLETED 3 Cost Completion Year (Millions)

1. Mark i Torus 31.9 1983 l
2. Multipurpose Facility (20,500 sq. ft.)

5.6 1984 47.3 1985

3. Pipe Replacement
4. Plant Management Information System 14.6 1986 l
5. Training Facility (29,000 sq. ft.)

3.0 1986

6. Equipment Qualification Project 7.7 1986
7. Appendix "R" Improvements 5.2 1986

MAJOR FACILITY IMPROVEMENTS UNDERWAY Estimated Cost Completion Year (Millions)

1. Office Building Addition (20,000 sq. ft. new, 3.2 1988 16,000 sq. ft. remodeling)
2. Control Room Design Review (CRDR) Modifications 5.5 1989
3. Security System Upgrade 4.0 1989
4. Plant Simulator 15.0 1990

l. POTENTIAL MODIFICATIONS 3 (Regulatory Driven) 1 i l l Estimated Cost Completion Year i (Millions) i {

1. Station Blackout Modifications 1.8 1989 i

i

2. Mark 1 Containment Venting Modifications 5.0 1990 1

l l i I l 1 i i

COOPER NUCLEAR STATION

SUMMARY

OF 1986 PERFORMANCE Latest Latest Actual 1986 1986 Industry industry Performance Goal Median Best Quartile

1. Equivalent Availability %

71.9 2 70 63.7 74.5

2. Forced Outage Rate %

1.2 s 3.0 7.2 2.4

3. Thermal Performance BTU /KWH 10,231 s 10,350 10,284 10,184
4. Unplanned Automatic Scrams 2

s3 4 2

5. Unplanned Safety System Actuations 2

0 0 0

6. Personnel Radiation Exposure Man-Rem 304.3 s650 781 542
7. Low Level Radwaste Shipments Cubic Meters 434.6 s400 709 602
8. Fuel Reliability - Micro Curies Per Gram.000268 s.0013

.0010 .0J010 t

9. Lost Time Accident Rate 0

s1 .33 .09 j Accidents per 200,000 Man-Hours i i

] 1 1987 l i COOPER NUCLEAR STATION PERFORMANCE INDICATOR STATUS I i THRU APRIL Year To Date 1987 Goal

1. Equivalent Availability INPO:

81.6 2 80 ) Unit Availability Factor: 91.8 j (Percent) 2. Unplanned Automatic Scrams 4 s2 1 1 3. Collective Radiation Exposure

  • 34.701 s200 j

(Man / Rem)

4. Volume of Low Level Solid Radwaste 177.6

< 350 i (Cubic Meters) 5. Lost Time Accident Rate 0 s 0.5 j (Per 200,000 Man-Hours Worked) I J

6. Unplanned Safety System Actuations 2

s2 4 j 7. Forced Outage Rate 3.9 <3 l (Percent)

8. Thermal Performance Gross 10,097

< 10,300 l (Heat Rate, BTU /KWH) s 9. Fuel Reliability 1.78 E-04 < 3.0 E-4 ) i (lodine Activity, Microcuries/ Gram) l

  • Thru March i

INPO EVALUATIONS August 1986 Total Findings 23 l New Findings 15 Related Findings 8 Major Areas for improvement - Radiation Protection -Industrial Safety - Post Maintenance Testing l - Procedure Upgrade Program INPO Rating (1-5) - 3 i September 1985 i Total Findings 41 New Findings 22 Related Findings 19 i Major areas for improvement - Management and Supervisory involvement - Correction of Recognized Problems 4 i - Training - Industrial and Radiological Safety Work Practices i Overall Rating (1-3) - 3 (Marginal) 4 I

~ COOPER NUCLEAR STATION SALPS Previous Present ~ Function 7/83-1/85 2/85-7/86 PlantOperations 2 1 RadiologicalControls 2 2 Maintenance 2 2 Surveillance 2 2 Fire Protection 1 2 t Emergency Preparedness 2 2 Security 2 3 Outages 1 1 i Ouality Programs 2 2 i Licensing Activities 1 1 Training and Qualifcation 3 2 I i I

r NPPD FITNESS FOR DUTY (FFD) PROGRAM Nov 1,1985 Established Drug Testing Program for NPG

  • Preemployment
  • For cause o Annual Apr 18,1986 NPPD Employee Lawsuit Filed in Federal Court Aug 4,1986 NRC Policy Statement on FFD issued Dec 18,1986 Revised NPPD FFD Program o Expanded preemployment and for cause testing company wide.

o For NPG, added random testing. f Feb 23,1987 Received Court Decision Mar 25,1987 Court Decision Appealetf Apr 9,1987 Commenced RanoSr.; fr3 A ng June 18,1987 Grandfather period ends. FFD will apply to all required unescorted access to CNS - Contractors, Consultants, NRC, etc. ( 1 l

DRUG TESTING Tests Conducted 1985 1986 1987 To Date For CNS Access NPPD 45 581 515 1141 58 58 Contractors Random 22 22 Non-Nuclear (Preemployment) 90 90 For Cause 0 0 0 0 Total 45 581 685 1311 Results (Positive for lilegal Drugs) Nuclear 2 Non-Nuclear 4 )

e. w June 1, 1987 Docket No. 50-298 MEMORANDUM FOR: Jose A. Calvo, Chief Project Directorate - IV DivisionofReactorProjects,III, -IV, V and Special Projects FROM: William Long, Project Manager ProjectDirectorate-IV DivisionofReactorProjects,III, IV, V and Special Projects

SUBJECT:

VISIT OF COMMISSIONER BERNTHAL TO COOPER NUCLEAR STATION On May 19, 1987, Commissioner F. M. Bernthal and his assistant J.F. Meyer visited the Cooper Nuclear Station for a meeting and plant tour. Copies of the attendance list and presentation slides are enclosed for your information. Mginst e1ON William 0. Long, Project Manager ProjectDirectorate-IV Division of Reactor Projects - III, IV, V and Special Projects

Enclosures:

As stated DISTRIBUTION Docket File NRC PDR Loca14PDRs PD4 Reading WLong PNoonan D. Dubois J. Gagliardo R. Hall J. Meyer F. Schroeder D. Crutchfield F. Miraglia C. Miller J. Sneizek J. Taylor an (Af T. Murley ~ l R. Martin 4 l V. Stello PD4 _WLona:.ai, t > 'r i 1 t

ENCLOSURE 1-COMMISSIONER BERNTHAL MEETING ATTENDEES. NRC Washington, D.C. - Frederick Bernthal, Commissioner Jim Meyer, Staff Assistant NRC/NRR - W. Long NRC. Region IV - Ray Hall John Jaudon NRC Site Resident Inspectors - Dennis DuBois Elden Plettner 3 -Board of Directors - Fred Harrington Ralph Johnson Iowa Power and Light - Jim Bull NPPD' - Don Schaufelberger - President and Chief Executive Officer Hugh Parris - Special Assistant to the President Larry Kunc1 - Vice President - Nuclear George Trevors - Division Manager for Nuclear Support Bob Wilbur - Division Manager of Nuclear Engineering and Construction Vern Wolstenholm - Division Manager of i Quality Assurance Dave Whitman - Program Control Manager Guy Horn - Division Manager for Operations Jim Dutton - Nuclear Training Manager Sam Peterson - Plant Services Manager (Acting) Garret Smith - Quality Assurance Manager (Site) Bob Jansky - Outage Coordinator Kim Walden - Manager Nuclear Licensing and Safety 4 I - -. - - _.,, _,, -..... _...... - - - _, _.., -., - ~ . -,., ~ - _ _. - - - - _, _ _ _,

~ ENCLOSURE 2 NEBRASKA PUBLIC POWER DISTRICT BOARD OF DIRECTORS Nuclear Power Group i PRESIDENT VICE - PRESIDENT NUCLEAR DIVISION MANAGER I NUCLEAR SUPPORT - Training Licensing Overview of Nuclear Activities Interface With Outside Groups i I I DIVISION MANAGER DIVISION MANAGER DIVISION MANAGER ENGINEERING AND NUCLEAR OPERATIONS OUALITY ASSURANCE CONSTRUCTION Operations - Site - Design Engineering PROGRAM CONTROL MANAGER - Engineering General Office Projects Construction - Maintenance Vendor Audits Budgeting I - Radiologal Configuration Management Planning - Security Design Basis Verification Policies & Procedures - Material Control Fuel Program Maintenance - Administration Financial Analysis

l ~ l I Nuclear Power Group i Employment l (Full Time Employees) 500 -- 467 ] 450 -- 415 ) 400 -- 350 -- 300 -- 284 250 -- V y o l 1983 1984 1985 1986 1987 1988 E S{e OcishshuarenH nua l

O Operation nd Mal tena e po se Less Fuel \\.(> 50 I + 35 30 25 L H,.,x N' 20 c 15 q e

4

.0 b i O Year N i

COOPER NUCLEAR STATION .Capit:1 Exp:nditures f:5 g,y..,..> E:.: t:l 3 E:::... p: M

'.j 40 f:': '

')

p..

.: ) E! M 5' '), p:::

. )

ss . v s' E.:. p:: 0,,'] p;; p'. ;), b:I::

.'i 30
g..sq

.,) t ]$ t

t. :3 t:

i E.3 ' 'i 25-t:: ' E:::.. k:,.X U-; ;~ 20 F: :s '(. ..i s 0.-: s E:.:

:),

p, .) ' s' 15-F. ; V. / i t: '['h ' :h p y,. $l p 'iq [.. ) ~ p h::h f. j l 'Al -.) 0 1979 1980 1981 1982 1983 1984 1985 1986 1987* 1988* Year wetsmate

~ MAJOR FACILITY IMPROVEMENTS COMPLETED Cost Completion Year (Millions)

1. Mark i Torus 31.9 1983
2. Multipurpose Facility (20,500 sq. ft.)

5.6 1984

3. Pipe Replacement 47.3 1985
4. Plant Management Information System 14.6 1986
5. Training Facility (29,000 sq. ft.)

3.0 1986

6. Equipment Qualification Project 7.7 1986
7. Appendix "R" Improvements 5.2 1986 L

MAJOR FACILITY IMPROVEMENTS UNDERWAY Estimated Cost Completion Year (Millions)

1. Office Building Addition (20,000 sq. ft. new, 3.2 1988 16,000 sq. ft. remodeling)
2. Control Room Design Review (CRDR) Modifications 5.5 1989
3. Security System Upgrade 4.0 1989
4. Plant Simulator 15.0 1990

1 i 1 POTENTIAL MODIFICATIONS f (Regulatory Driven) I Estimated Cost Completion Year j (Millions) 1

1. Station Blackout Modifications 1.8 1989 i

j

2. Mark 1 Containment Venting Modifications 5.0 1990 i

l i i )

l COOPER NUCLEAR STATION i

SUMMARY

OF 1986 PERFORMANCE Latest Latest i Actual 1986 1986 Industry Industry Performance Goal Median Best Quartile I l

1. Equivalent Availability %

71.9 2 70 63.7 74.5 l

2. Forced Outage Rate %

1.2 s 3.0 7.2 2.4

3. Thermal Performance BTU /KWH 10,231 s 10,350 10,284 10,184 l
4. Unplanned Automatic Scrams 2

s3 4 2 4

5. Unplanned Safety System Actuations 2

0 0 0

6. Personnel Radiation Exposure Man-Rem 304.3 s650 781 542
7. Low Level Radwaste Shipments Cubic Meters 434.6 s400 709 602
8. Fuel Reliability - Micro Curies Per Gram.000268 s.0013

.0010 .00010

9. Lost Time Accident Rate O

s1 .33 .09 Accidents per 200,000 Man-Hours 1 i

1987 COOPER NUCLEAR STATION PERFORMANCE INDICATOR STATUS THRU APRIL Year To Date 1987 Goal

1. Equivalent Availability INPO:

81.6 2 80 Unit Availability Factor: 91.8 (Percent)

2. Unplanned Automatic Scrams 4

s2

3. Collective Radiation Exposure
  • 34.701 s200 (Man / Rem)
4. Volume of Low Level Solid Radwaste 177.6

< 350 (Cubic Meters) 5. Lost Time Accident Rate 0 s 0.5 (Per 200,000 Man-Hours Worked) 6. Unplanned Safety System Actuations 2 52 7. Forced Outage Rate 3.9 <3 (Percent) a

8. Thermal Performance Gross 10,097

< 10,300 (Heat Rate, BTU /KWH) 9. Fuel Reliability 1.78 E-04 < 3.0 E-4 (lodine Activity, Microcuries/ Gram)

  • Thru March

INPO EVALUATIONS August 1986 Total Findings 23 New Findings 15 Related Findings 8 Major Areas for improvement - Radiation Protection -Industrial Safety - Post Maintenance Testing - Procedure Upgrade Program INPO Rating (1-5)- 3 September 1985 Total Findngs 41 New Findings 22 Related Findings 19 Major areas for improvement - Management and Supervisory involvement. - Correction of Recognized Problems - Training - Industrial and Radiological Safety Work Practices Overall Rating (1-3)- 3 (Marginal)

9 COOPER NUCLEAR STATION SALPS 4 Previous Present Function 7/83 -1/85 2/85-7/86 PlantOperarons 2 1 RadiologicalControls 2 2 Maintenance 2 2 l Surveillance 2 2 I i Fire Protecton 1 2 3 Emergency Preparedness 2 2 i Secun'ty 2 3 i j Oy 1 1 4 Quality Programs 2 2 Licensing Achvities 1 1 I Training and Qualifcation 3 2 i 1

O NPPD ~ FITNESS FOR DUTY (FFD) PROGRAM Nov 1,1985 Established Drug Testing Program for NPG

  • Preemployment o For cause o Annual Apr 18,1986 NPPD Employee Lawsuit Filed in Federal Court Aug 4,1986 NRC Policy Statement on FFD issued Dec 18,1986 Revised NPPD FFD Program o Expanded proomployment and for cause testing company wide.

o For NPG, added random testing. Feb 23,1987 Recolved Court Decision Mar 25,1987 Court Decision Appealed Apr 9,1987 Commenced Random Testing June 18,1987 Grandfather period ends. FFD will apply to all required unescorted access to CNS - Contractors, Consultants, NRC, etc.

t DRUG TESTING Tests Conducted 1985 1986 1987 To Date For CNS Access NPPD 45 581 515 1141 58 58 Contractors Random 22 22 Non-Nuclear (Preemolovment) 90 90 i For Cause 0 0 0 0 To t al-45 581 685 1311 Results (Positive for lilegal Drugs) 2 Nuclear Non-Nuclear 4

June 1, Avoj Docket No. 50-298 MEMORANDUM FOR: Jose A. Calvo, Chief Pro;;ect Directorate - IV Divi sion of Reactor Pro;'ects, III, IV, V and Special Pro;;ects FROM: WilliamLong,ProjectManager Pro;iect Directorate - IV Div"sion of Reactor Projects, III, IV, V and Special Projects

SUBJECT:

VISIT OF C0 M ISSIONER BERNTHAL TO COOPER NUCLEAR STATION On May 19, 1987, Commissioner F. M. Bernthal and his assistant J.F. Meyer visited the Cooper Nuclear Station for a meeting and plant tour. Copies of the attendance list and presentation slides are enclosed for your information. Sgtnals @ N William 0. Long, Project Manager Pro;;ect Directorate - IV Div< sion of Reactor Pro;ects - III, IV, V and Special Pro;ects

Enclosures:

As stated DISTRIBUTION Docket File K POR' ,LocalLPOR*" PD4 Reading WLong PNoonan D. Dubois J. Gagliardo R. Hall J. Meyer F. Schroeder D. Crutchfield F. Miraglia C. Miller J. Sneizek J. Taylor T. Murley R. Martin qq,y_,1 ell'&f-PD4 0-i & T '- ' 't ' WLona:,a1 N t, , 17

ENCLOSURE 1 COMMISSIONER BERNTHAL MEETING ATTENDEES NRC Washington, D.C. - Frederick Bernthal, Commissioner Jim Meyer, Staff Assistant NRC/NRR - W. Long NRC Region IV - Ray Hall John Jaudon NRC Site Resident Inspectors - Dennis DuBois Elden Plettner Board of Directors - Fred Harrington Ralph Johnson Iowa Power and Light - Jim Bull NPPD - Don Schaufelberger - President and Chief Executive Officer Hugh Parris - Special Assistant to the President Larry Kunci - Vice President - Nuclear George Trevors - Division Manager for Nuclear Support Bob Wilbur - Division Manager of Nuclear Engineering and Construction Vern Wolstenholm - Division Manager of Quality Assurance Dave Whitman - Program Control Manager Guy Horn - Division Manager for Operations Jim Dutton - Nuclear Training Manager Sam Peterson - Plant Services Manager (Acting) Garret Smith - Quality Assurance Manager (Site) Bob Jansky - Outage Coordinator Kim Walden - Manager Nuclear Licensing and Safety

ENCLOSURE 2 NEBRASKA PUBLIC POWER DISTRICT BOARD OF DIRECTORS Nuclear Power Group PRESIDENT VICE - PRESIDENT NUCLEAR DIVISION MANAGER NUCLEAR SUPPORT Training Licensing Overview of Nuclear Activities interface With Outside Groups I l l DIVISION MANAGER DMS10N MANAGER DIVISION MANAGER ENGINEERING AND NUCLEAR OPERATIONS OUALITY ASSURANCE CONSTRUCTION Operations - Site Design Engineering PROGRAM CONTROL MANAGER Engineering GeneralOffice Projects - Maintenance Vendor Audits Construction Budgeting - Radiological Conhguration Management Planning - Security Design Basis Verification Policies & Procedures MaterialControl Fuel Program Maintenance - Administration Financial Analysis

Nuclear Power Group Employment (Full Time Employees) 500 - 467 450 -- 415 400 -- 350 -- 3-300 -- 284 262 y i y 1983 1984 1985 1986 1987 1988 ruai t eis s u aren l l

COOPER NUCLEAR STATION Operation and Molntenaco Expense Less Fuel as 50 c g s. N.a 48 s P 88 30 s. y% (L. 25 I h ki lb [i [a i n 4 % fj l 1979 1980 1981 1982 198 1984 1985 1986 1987* 1988* e

COOPER NUCLEAR STATION Capit:1 Expenditures r x. (- ci?, f:':'S f:':: S c:' I ) 40 p::.v F:,: d

' ;>)
  • ,. i 35

,. N ?, ) I*'. F.,- s E:NN f::'3

' I 30

), I': 8 (:

V p-l Id I' l

25-h:K.:d ): d I'..'N'f{.:,'l L .:.v C. ' s 20 f(!!(3 <!;' bk '

. '. ),

P l. F: :>N '.? p-{:.qp ',g,. 15 h b'.'.!',3 P' ?, d* i" k>v b) 1 'A N.. i ' q . ):.L>., '

>sq.

U v )

.i L

< ::q:-:. '3 r 10 t j @b (' ( q R )F' ' {',)', s'$$ l ' ::>A f> O' sq ' sb. >>4' :.: ':3 ([:' ev ~P 5 esp, g. '

R

!.:.g P g, g: 1 2 l,' a 1979 1980 1981 1982 1983 1984 1985 1988 1987* 1988* Year T.'stimato

i MAJOR FACILITY IMPROVEMENTS COMPLETED ) Cost Completion Year (Millions) 1

1. Mark I Torus 31.9 1983 f
2. Multipurpose Facility (20,500 sq. ft.)

5.6 1984 1

3. Pipe Replacement 47.3 1985 1

l I

4. Plant Management information System 14.6 1986 l
5. Training Facility (29,000 sq. ft.)

3.0 1986

6. Equipment Qualification Project 7.7 1986
7. Appendix "R" improvements 5.2 1986 l

~ MAJOR FACILITY IMPROVEMENTS UNDERWAY Estimated Cost Completion Year (Millions)

1. Office Building Addition (20,000 sq. ft. new, 3.2 1988 16,000 sq. ft. remodeling)
2. Control Room Design Review (CRDR) Modifications 5.5 1989
3. Security System Upgrade 4.0 1989
4. PlantSimulator 15.0 1990

i POTENTIAL MODIFICATIONS (Regulatory Driven) Estimated Cost Completion Year (Millions)

1. Station Blackout Modifications 1.8 1989
2. Mark 1 Containment Venting Modifications 5.0 1990 1

COOPER NUCLEAR STATION

SUMMARY

OF 1986 PERFORMANCE j Latest Latest Actual 1986 1986 Industry Industry Performance Goal Median Best Quartile 1

1. Equivalent Availability %

71.9 2 70 63.7 74.5 1 l

2. Forced Outage Rate %

1.2 s 3.0 7.2 2.4

3. Thermal Performance BTU /KWH 10,231 s 10,350 10,284 10,184
4. Unplanned Automatic Scrams 2

s3 4 2

5. Unplanned Safety System Actuations 2

0 0 0 i

6. Personnel Radiation Exposure Man-Rem 304.3 s650 781 542 2
7. Low Level Radwaste Shipments l

Cubic Meters 434.6 s400 709 602 l

8. Fuel Reliability - Micro Curies Per Gram.000268 s.0013

.0010 .00010 l

9. Lost Time Accident Rate 0

s1 .33 .09 Accidents per 200,000 Man-Hours

i i 1987 i COOPER NUCLEAR STATION i PERFORMANCE INDICATOR STATUS THRU APRIL Year To Date 1987 Goal

1. Equivalent Availability INPO:

81.6 2 80 4 i Unit Availability Factor: 91.8 l (Percent)

2. Unplanned Automatic Scrams 4

s2 )

3. Collective Radiation Exposure
  • 34.701 s200 l'I j

(Man / Rem) i 1

4. Volume of Low Level Solid Radwaste 177.6

< 350 i 4 (Cubic Meters)

5. Lost Time Accident Rate 0

s 0.5 (Per 200,000 Man-Hours Worked) 1 l 6. Unplanned Safety System Actuations 2 s2 i 7. Forced Outage Rate 3.9 <3 (Percent)

8. Thermal Performance Gross 10,097

< 10,300 l (Heat Rate, BTU /KWH) j ~ i j 9. Fuel Reliability 1.78 E-04 < 3.0 E-4 ~ (lodine Activity, Microcuries/ Gram)

  • Thru March i

INPO EVALUATIONS l August 1986 j Total Findings. 23 New Findings 15 i Related Findings 8 Major Areas for improvernent - Radiation Protection -Industrial Safety - Post Maintenance Testing ~ - Procedure Upgrade Program INPO Rating (1-5)- 3 September 1985 Total Findings 41 New Findings 22 Related Findings 19 Major areas for Improvement - Management and Supervisory involvement - Correction of Recognized Problems - Training - Industrial and Radiological Safety Work Practices Overall Rating (1-3) - 3 (Marginal) i

COOPER NUCLEAR STATION SALPS Previous Present Function 7/83 -1/85 2/85-7/86 PlantOperations 2 1 i RadiologicalControls 2 2 Maintenance 2 2 Surveillance 2 2 Fire Protection 1 2 Emergency Preparedness 2 2 Security 2 3 Outages 1 1 Quality Programs 2 2 Licensing Activities 1 1 Training and Qualification 3 2

l ~ NPPD FITNESS FOR DUTY (FFD) PROGRAM Nov 1,1985 Established Drug Testing Program for NPG

  • Preemployment
  • For cause o Annual Apr 18,1986 NPPD Employee Lawsuit Filed in Federal Court Aug 4,1986 NRC Policy Statement on FFD issued Dec 18,1986 Revised NPPD FFD Program o Expanded preemployment and for cause testing company wide.

o For NPG, added random testing. Feb 23,1987 Received Court Decision Mar 25,1987 Court Decision Appealed Apr 9, 1987 Commenced Random Testing June 18,1987 Grandfather period ends. FFD will apply to all required unescorted access to CNS - Contractors, Consultants, NRC, etc.

r DRUG TESTING Tests Conducted 1985 1986 1987 To Date For CNS Access NPPD 45 581 515 1141 Contractors 58 58 Random 22 22 Non-Nuclear (Preemployment) 90 90 For Cause 0 0 0 0 l Total 45 581 685 1311 Results (Positive for lilegal Drugs) Nuclear 2 Non-Nuclear 4 -}}