ML20214N414

From kanterella
Jump to navigation Jump to search
TMI Aquatic Study Monthly Progress Rept for Apr 1987
ML20214N414
Person / Time
Site: Crane  
Issue date: 04/30/1987
From:
RADIATION MANAGEMENT CORP. (RMC)
To:
Shared Package
ML20214N361 List:
References
NUDOCS 8706020167
Download: ML20214N414 (14)


Text

--

w.

THREE MILE ISLAND AQUATIC STUDY MONTHLY PROGRESS REPORT FOR APRIL 1987 Prepared For GPU Nuclear Corporation P. O. Box 480, Route 441 South Middletown, Pennsylvanid 17057 By RMC Environmental Services 1921 River Road, P. O. Box 10 Drumore, Pennsylvania 17518 May 1987 E

8706020167 870522 t

PDR ADOCK 05000284 R

PDR 1,

s 2

INTRODUCTION The objective of this monthly report is to document compliance with the nonradiological (aquatic) environmental-monitoring programs specified in Sections 3.l.la(4),

~3.1.2a., and 4.6.1 of the Environmental Technical I

Specifications (ETS).

These programs have been carried out as directed in the Environmental Controls Aquatic Sampling Manual.- Program elements being conducted under contract to j

GPU Nuclear Corporation include benthic macroinvertebrates, ichthyoplankton, fish population dynamics (seine and electrofishing), creel surveys, and water quality.

The ultimate purpose of these studies is td obtain a database sufficient to establish the natural fluctuations within the ecosystem and identify any significant biological alterations resulting from the Three Mile Island Nuclear Station (TMINS).

Compliance with all programs specified in the ETS and 4

detailed in the Aquatic Sampling Manual was achieved in April 1987 (Table 1), with the exception of ichthyoplankton sampling during the week of 5 April.

High river flow

(>150,000 cfs) and hazardous sampling conditions necessitated cancellation of the program until the following week.- The following changes in the TMINS Aquatic Sampling Schedule were made during April: seining originally i.

scheduled for 7 April was conducted on 15 April and t

1 i

.3 4

electrofishing scheduled for 15 April was completed on-22 April.

River flow and turbidity are-given as rationale for these changes.

Details are provided in the following pages wherein progress for each program is described.

Data presented herein are considered provisional, pending subsequent proofing, analysis, and presentation in the annual report.

8 Benthic Macroinvertebrates Objective: To assess the abundance, distribution, and diversity of benthic macroinvertebrates at three stations in the vicinity of TMINS.

i Progress: Replicate (4) macroinvertebrate samples were-l collected at each of the three stations on 2 April 1987 I

(Table 1).

Sorting of the 2 April samples has been completed; identification is in progress.

l l

l Ichthyoplankton r

Objective: To determine species composition, relative abundance, density, and seasonal and spatial l

distribution of ichthyoplankton at eight stations in the vicinity of TMINS.

i 2

l l

Progress: Replicate (2) ichthyoplankton samples were taken at ea,ch of the eight stations on 14, 21, and 28 April 1987 (Table 1).

Sampling during the week of 5 April was cancelled due to high river flow and hazardous sampling conditions.

All samples collected through 14 April have-been sorted; no ichthyoplankton were found.

Seine Ob$ective: To assess species composition, relative abundance, seasonal and spatial distribution, condition factor, occurrence of parasites, anomalies and fish kills, and species diversity of fishes vulnerable to seine capture at six stations in the vicinity of TMINS.

Progress: Seine collections were taken at each of the six stations on 15 April 1987 (Table 1).

A total of 3325 fish of 7 species was collected (Table 2).

Most fish (1788) were taken at Station 13B5; most species (6) were collected at Station 4A2.

Spotfin shiner dominated the catch of each station.

Parasites and anomalies observed were: anchor womrs (Lernaea) on 1 mimic shiner; black spot on 77 spotfin shiner, 3 bluntnose minnow, and 1 tessellated darter; and pugheadedness on 2 spotfin shiner and 3 mimic shiner.

3

m Electrofishing s

Objective: to assess species composition, relative abundance, occurrence of parasites, anomalies, and species: diversity of fishes vulnerable to electrofisher capture at six stations in the vicinity of TMINS.

Progress: Electrofishing at six stations was completed on 22-23 April 1987 (Table 1).

A total of 301 fish of 17 species was collected (Table 3).

More fish (90 specimens) were collected at Station llB1 than at any-other station; most species (12) wire collected from Station 13A1.

Redbreast sunfish and pumpkinseed dominated the catch.

Ectoparasites observed on fishes 1

collected were: anchor worms (Lernaea) on two pumpkinseed; and leeches on two channel catfish, seven redbreast sunfish, two pumpkinseed, and one smallmouth bass.

Black spot was observed on one walleye.

Creel Survey Objective: To investigate the extent of success of sportfishing, and determine angler-residence and use of catch, in the Susquehanna River near TMINS.

4

Progress: Creel surveys were conducted on 9, 11, 14, and 19 April 1987 (Table 1).

Interviews consisted of 322 anglers who reportedly fished 513.16 hours1.851852e-4 days <br />0.00444 hours <br />2.645503e-5 weeks <br />6.088e-6 months <br />, caught 624 fish, and harvested 278 fish (44.6% of'the total catch)

(Tables 4 through 7).

The average catch per effort (c/e) and harvest per effort were 1.22 and 0.54 per hour, respectively.

'Smallmouth bass and walleye were the predominant fishes caught (113 and 162 specimens, respectively); pumpkinseed and bluegill dominate those harvested (60 and 46 specimens, respectively).

Most anglers (138) and most hours fished (216.08) were recorded at the York Haven Generating Station.

Most fish were caught (262) and harvested (140) from the East Dam, which also produced the highest c/e (3.26).

Anglers were predominantly residents of York or Dauphin counties and the majority indicated that they eat at least a portion of their catch.

Water Quality Analysis Objective: To measitre select physical and chemical parameters of the Susquehanna River in the vicinity of TMINS concurrent with General Ecological Survey samples.

5

1 Progress: Water quality samples were collected on 2 April 1987 and forwarded to TMI-EC (Table 1).

Selected s

water quality parameters were also measured at sampling times and locations described in the Aquatic Sampling Manual.

t l

-t

't 6

.~ _ __

TABLE 1 Sampling conducted in April 1987 in compliance with Three Mile Island Nuclear Station's Environmental Technical Specifications.

X's equal week in which program completed.

PROGRAM APRIL 1-4 5 12-18 19-25 26-30 Benthic Macroinvertebrates X

Ichthyoplankton X

X X

Seine X

Electrofishing X

Creel Survey XX X

X Water Quality Analysis X

t I

7

. ~.

TABLE 2 Fishes taken by seine on 15 April 1987 near TMINS.

Station

  • 1385 1085 16A1-10A2 983 4A2 Total % Catch Time 0930 1010 1250 1220 1150 1055 Air Temp (C) 12.0 14.0 14.8 14.8 14.5 15.0 Water Temp (C) 11.5 12.0 11.8 12.2 12.1 17.5 Dissolved Oxygen (mg/1) 10.8 11.0 10.4 10.5 10.5 10.5 pH 7.2 7.3 6.8 6.9 6.9 7.1 Seccht Disc (cm) 83.8 81.3 48.3 48.3 38.1 76.2 River Stage (m) 2.18 2.18 2.18 2.18 2.18 2.18 Weather Over-Over-Over-Over-Over-Over-cast cast cast cast cast cast

' I No. of Specimens 1788 5

21 181 205 1125 3325 No. of Species 5

1 2-3 4

6 7

No. of Hauts 3

4 4

3 3

3 20 Comely shiner 1

7 8

0.2 Spottail shiner 1

2 7

10 0.3 Spotfin shiner 1545 5

20 165 170 1036 2941 88.4 Mimic shiner 236 15 31 62 344 10.3-Bluntnose minnow 5

1 2

12 20 0.6 Smallmouth bass 1-1

+

Tessellated darter 1

1

+

  • Station prefix TM-SE-deleted from table.

a2

+ Less than 0.05%.

I d

l i

o e

1

/

AI, s

( /

TABLE 3 Fishes captured by'the AC'electroffsher near TMINS on 22-23 April 1987.

Zone preftm TM-EL-coleted from table, Zone 4A1 1341 10A3 985 1083 1181 Total Time 2122 2224 2330 0037 2015 0128 Duration (min) 24 -

24

-- 2 0

. 20 25

. 35 Air Temp (C).

14.0 13.5 13.0 13.5 15.0 13.0 water Temp (C) 17.9 17.8 17.6 17.5 18.8 17.4 t

Dissolved Oxygen (mg/1) 9.8 9.7 9.2

9. 4 -

11.4 8.6 pH 7.6 7.0 7.1 7.1 7.6 7.1 Conductivity (micrombos/cm) 200 198 199 200 170 225 Secchi Disc (cm) 61.0 50.8

.48.3 50.8-66.0 53.3 Volts 215 220 220 210 220 210 Amps 5.0 5.0 5.0 4.0 5.0 4.0 Common carp 2

1 3

Golden shiner 1

1 Common shiner 1

1 Qu111back.

2 3

9 2

5

12 33 White sucker 1~

4 6

3 1

15 Shorthead redhorse 1

3 4

Channel catfien 1

1 1

3 y_

Rock bass

~ 7 1

1 9

Redbreast sunfish 2

25 23 6

1 57 Green sunfish 4

2

. 6 Pumpkinseed 6

1 7

7 8

69 98 Bluegill 1

7 7

15 Smallmouth bass 2

23 5

2 2

34 c

Largemouth bass 2

2

~

white crapple 1-1 t

Tesse11sted darter 1

1 walleye 2

12 3

1 18 No. of Specimens 16 74 68 26 27 90 301 No. of Species 7

12 9

9 9

5

.17 t

i I

i I

4

TACLE 4 Creet survey data from the General Reservoir (GR) for each survey day in April 1987.

Day 9 Thu 11 Sat 14 Tue 19 Sun Weather Clear: Partly Clear: Partly Partly Cloudys Partly Cloudy Cloudy Cloudy: Overcast Clear River Stage (m) 3.54 2.78 2.08 1.96 Air Temp (C) 9.5 14.0 15.5 13.0 18.5 17.0 10.0 15.5 17.0 17.5 20.0 19.0 Water Temp (C) 8.3 8.5

- 8.5 10.0 10.5 10.5 10.0 11.5 11.0 11.5 12.0 12.5 Times:

a) morning (0900-1300) a a

a a

~

b) afternoon (1301-1700) b b'

b b

c) evening (1701-2100) c c

c c

Total Per Time Period:

TOTAL Anglers 4

3 30 21 5

.13 11 11 23 7

128 Fish Caught 2

21 13 40 6

27 56 6

171 Fish Kept 3

1 3

3 24 50 2

88 Hours Fished 7.00 0.75 56.00 50.00 1.25 27.25 14.50 8.50 36.50 14.00 215.75 Catch / Effort (h) 0.28 0.38 0.26 1.47 0.41 3.18 1.53 0.43 0.79 Days Totals:

Anglers 7

51 29

-41 Fish Caught 2

34 46 89 Fish Kept 4

8 76 Hours Fished 7.75 106.00 43.00 59.00 Catch / Effort (h) 0.26 0.32 1.07 1.51 w

O Species Common carp 1K IR IK 1R 2

Channel catfish 1R 2R 2K 2K 2R 1R 4K 6R 10 Redbreast sunfish ISK 24K 39K - 39 Pumpkinseed 4K 6K 1K 11K 11 Bluegill 30R 4K 19K1R 23K 31R 54 Sunfishes (Lepomis spp.)*

2R 3R

- SR

.5 Smallmouth bass 2R 3K15R 10R

- IK3R 3KIR IK2R 8K 33R 41 Largemouth bass 3R IK.

1K 2K 3R 5 White crappie IR 1R 2R 2 Walleye 2R 2R 2

  • General Identification K Kept R Released a

TA8LE 5 Croot survey d:ta frcm tho 130st dim (WD) for cach survey dDy in April 1987

' e..

. Day 9 Thu 11 Sat 14 Tue 19 Sun weather Clear: Partly Clear: Partly Partly. Cloudy:

Partly Cloudy Cloudy Cloudy: Overcast Clear River Stage (m) 3.54 2.78 2.08 1.96 Air Temp (C)-

9.5 14.0 15.5 13.0 17.0 17.0 10.0 14.0 16.0 18.0 19.5 16.5 water Temp (C) 8.0 8.0 8.0

8,5 9.5 10.0 10.0 10.5 ' 11.5 12.0 12.5 -13.5 Times:

a) morning (0900-1300) a a

a a

b) afternoon (1301-1700) b b

b b

c) evening (1701-2100) c c

c

.c Total Per Time Period:

TOTAL Anglers 1

1 Fish Caught

~-

1-1 Fish Kept

'1 1

~

Hours Fished 1.00 1.00 Catch / Effort (h) 1.00 1.00 Days Totals:

Anglers 1

Fish Caught 1

Fish Kept 1

. Hours Fished 1.00 Caten/ Effort (h) 1.00 Species

[

Brook Trout 1K IK - 1 K Kept O

1

. 9 TA%LE 6

~

Creol' survey data frem the Ecst Dim (ED) for occh surv y dGy-in. April 1987 Day 9 Thu-11 Set 14 Tue

.19 Sun' weather Clear: Partly Clear: Partly Partly Cloudy Partly Cloudy

-. Cloudy Cloudy: Overcast Cleer River Stage (m) 3.54 2.78 2.08 1.96 Air Tomo (C) 9.5 14.0 -115.5. 13.0 25.0 17.0 12.5 15.5 15.0 15.0 18.0 24.5 water Temp (C) 8.0-9.0 9.5 10.5 11.0 11.0 10.3 11.5 12.5 12.0 12.7 14.0 Times:

a) morning (0900-1300) a a

a a

b) afternoon (1301-1700) b b

b b

c) evening (1701-2100) c c

c

'c Total Per Time Portoo:

+

TOTAL Anglers 2

6 8

7 6

8 5.

6

. 7 55 Fish Caught 1

16 2

12 47 26 23 77 58 262

  • Fish Nept 4

2 5

33 11 21.

58 6

140 Hours Fished 0.25 8.50 11.25 5.50 11.00 5.25 3.00 18.83 16.75 80.33 Catch / Effort (h) 4.00 1.88 0.18 2.18 4.27 '4.95 7.67 4.09 3.46 3.26 Days Totals:

Anglers 2

14 21 18 Fish Caught 1

18 -

85 158 Fish Kept 6

49

. 85 Hours Fished 0.25 19.75 21.75 38.58 Catch / Effort (h) 4.00 0.91 3.91 4.10 Species gu Muskellunge 2R 2R 2 Common carp 1K IK I

white sucker 1K 1K

- 1 Channel catfish 1R IK IK 1R 2-Rock bass 2K 18K 1K1R 4K SK 2K 35K 1R 36 Redbreast sunfish 5K SK

- 5 Pumpkinseed

- 9K9R 9KIR 27K 4K

-49K 10R 59 81uest11 8K' 15K' 23K

- 23 Sunf1shes (Lepomis spp.)*

4K 15K 4R 19K 4R 23 Smallmouth bass 2K IR 9R. 1K1R 1R 1K12R.

11R

,4K 35R 39 Largemouth bass 1R.

1K IK 1R 2 Black crapple IK 1K

- 1 Ima 11 eye 10R 6R 4R 4R 3R 41R

-- 68R 68

  • General Identification K Kept R Released o

9

TAOLE 7 Crool c.urvey cir.to f rom tha verk Haven Gensrcting Statian (VHGS) for occh Euv0y Ccy in April 1987.

Day 9 Thu.

11 Sat 14 Tue ~

19' Sun weather Clear: Partly Clear; Partly

' Partly Cloudy; Partly Cloudy Cloudy Cloudy:Lt. Rain Clear Ptly. Cloudy River Stage (m) 3.54 2.78 2.08 1.96 Air Temp (C) 12.5 17.0 16.5 20.0 20.5 14.0 13.0 17.5 16.0 18.0 23.0 20.0 Water Temp (C) 8.5 8.5 9.0 10.5 10.5 11.0 13.0 13.0 11.5 12.5 15.0 14.5 Times a) morning (0900-1300) a a

a a

b) afternoon (1301-1700) b b

b b

c) evening (1701-2100) c c

c c

Total Per Time Period:

TOTAL Anglers 5

4 10 11 22 13 7

12 13 2

15 24-138 Fish Caught 12 33 10 30 10 11

'S 9

3 4

36 27 190 Fish Kept 1

3 14 5

5 3

3 4

4 7

49 Hours Fished 7.00 9.00 6.00 27.50 42.00 24.50 10.50 25.00 8.25 6.00 15.58 34.75 216.08 Catch / Effort (h) 1.71 3.67 1.67 1.09 0.24 0.45 0.48 0.w6 0.36 0.67 2.31 0.78 0.88 Days Totals:

Anglers 19 46 32 41 Fish Caught 55 51 17 67 Fish Kept 4

24 6

15 Hours Fished 22.00 94.00 43.75 56.33 Catch / Effort (h) 2.50 0.54 0.39 1.19 Species Brown Trout IR

- IR 1

M Muske11unge 2R 2R 2

Common carp IR 2K IR 6R 2K 8R 10 White sucker 1R 3K 3K 1R 4

Channel catfish IR IK IK 5K4R 7K SR 12 Rock bass 1R 1R IK 2K11R 1K 4K 13R 17 Smallmouth bass IK 3K 14KIR SK3R

- IK1R IK 2R 1R 25K SR 33 White crappie 1K 3K 1K4R SK 4R

'9 Slack crappie IK 1K 1

Vellow perch IR 1K 6R IK 2K 7R 9

Walleye 12R 31R 6R 13R 6R 4R SR 8R 7K

- 92R 92 K Kept R Released a