7----
--------- 7 I
U.S. NUCLEAR RETULATORY COMMIS$10N testC postes ets CERTIFICATE CF CHMPLIANCE
==>
I toca n FOR RADIOACTIVE MATERIALS PACKAGES 1 a CERTIFICATE NUMBFR b REVIS40N NUMBER
- c. PACKAGE IDENTIFICATION NUMBER d PAGE NUMBER
- e. TOTAL feUMaER PAGES 9153 3
USA /9153/B( )
1 2
i l
2 PREAMBLE
- a. This certifcate is issued to certify that the packaging and contents desenbed in item 5 below, meets the appleable safety standards set forth in Title 10, Code I
of Federal Regulations Part 71,
- Packaging and Transportation of Radioactive Matertal."
l
- b. Thes certificate does not reheve the Consignor from Compliance with any requirement of'fhe regulations of the U.S. Department of Transportation or other q
appicable regulatory agencies, mctuding the government af any country through or into which the package will be transported.
3 THIS R11FICAT $ SSUE ON THE BASIS OF A SAFETY ANALYSIS RE T
TH PACKAGE S OR A ION l
Teledyne Energy Systems Teledyne Energy Systems application l
110 West Tisonium Road dated October 5,1981, as supplemented.
q fimonium, MD 21093 q
N 71-9153 g
c g,.,
- c. DOCKET NUMBER ?
=
4 CONDITIONS This certificate is conditional upon fulfilhng the requirerrients of 10 CFR Part 71, as appicable, and the conditions specified below.
I 4
5 N
(a)
Packaging E
d P
l (1) Model No.:
SENTINEL 1S l
(2) Desc ription ti it i
The packaging contains a thermoelectric generator with 10,100 ci of l
1 strontium 90 fluoride.
The dimensions-are 32.2 inches in height by I
37.53 inches in diameter. The package is welded to a 39.5 inch square, steel pallet, which is 4 inches high.
i 1
4 E
l The contents are housed in a Hastelloy C-276 liner. The liner, with I
its pressed cap, is contained within a fuel capsule ~(1.871" OD x E
d 4.194 ").
The capsule lid is threaded for strength and mlded (minimum f
(
weld penetration of 0.055" is specified) to give a positive seal.
The g
g wall thickness of the capsule is a minimum of 0.198 inches.
The fuel g
j capsule is constructed of Hastelloy C-276.
The capsule is inserted into the stainless steel canned depleted uraniun biological shield F
(1.898" ID x 4.320" OD x 5.885" or 5.978"), and the shield plug is E
bolted into place using three steel bolts, equally spaced on a 3.25-f f
inch bol t circle.
g l
The biological shield is held in a horizontal position within the I
generator's aluminum housing by the sized Min-K-1301 thermal insulation.
I:
1 Min-K and load bearing plates are used to support the shield base.
f-I Spring washers are used to preload the Min-K s'ttpporting the biological h
,1 shield.
{
I l
I l
(
I l
i I
I I
I I
e609160256 e60910 N
C PDR P-l l l-------------------------------------------------------l
+
A----__----_-------_-------
Ec I 4 Rt GULATesy covuissi ;,
CONDITIONS (continued) l I
Page 2 - Certificate No. 9153 - Revision No. 3 - Docket No. 71-9153 l
I I
I l
(2) Description (continued) i I
I I
I The finned (13" OD x 14.5") aluminum housing (7" OD x 8.97") foms the I
outer protective shell of the generator (70 lbs). The generator is l
l held in place within the cask by a hold down assembly with a rubber i
I pad on top and a 2-inch thick (1/8"-0.001" core) aluminum honeycomb l
l with a 97 square inch effective area, on the bottom. The total system I
weight is approximately 7,190 pounds.
l i
l (3) Drawings l
l W
I The packaging is constructed,in accordance with Teledyne Energy Systems g
I l
1 and 2, Rev. 0; Tnd' assembled'in)013;01001, Rev. 0; 013-01002, Drawing Nos.:
013-01000, Rey !>0;'
Sheets l
accordance with Figure 2.7-1, p 3-17 i
i of the applicatioriI
\\<,'I l
s i
j.,s.,
j,)
I (b) Contents V
(
g s
'4 g
I l
(1) Type and fom of material
- /
I Strontium fluoride-(90SrF ) doublyz encaps'ulated in3a Hastelloy C-276 l
s 7
1 fuel capsule, with a HastelloyJC-276 -liner which ' meets the requirements b
I of special form ' radioactive material.
O y
l 5
l (2) Maximun quantity of material per package i
i 12,000 curies.-
l 1
l' i
6.
The lif ting rings must be either removed, securely covered, or locked during I
transport to prevent their use as tie-down devices.
li d
b h
l 7.
The package authorized by this certificate is hereby approved for use under the q
general license provisions of 10 CFR 71.12.
l l
b q
8.
Expiration date:
September 30, 1991.
p
)
F 4
REFERENCES 4
R l
Teledyne Energy Systems application dated October 5,1981.
l a
4 Supplements dated:
October 21 and November 30, 1981.
p i
,\\
p W
FOR THE U.S. NUCLEAR REGU TORY COMMISSION P
I B
i Charles E. MacDonald, Chief y
I Transportation Certification Branch p
4 Division of Fuel Cycle and l
Material Safety, NMSS j
SEP 1019lE
[
Date:
4 i
4 W
L__________________________-_-_________________________1
pa rarg UNITED STATES NUCLEAR REGULATORY COMMISSION 3
o D
j WASHINGTON, D. C. 20555
\\...../
Transportation Certification Branch Approval Record Model No. Sentinel 1S Docket No. 71-9153 By application dated August 22, 1986, Teledyne Energy Systems requested renewal of Certificate of Compliance No. 9153.
No changes have been requested or made to the package since approval of the latest supplement dated November 30, 1981.
The staff concludes that the statements of the original application, as supplemented, satisfy the requirement for renewal of the certificate of compl iance.
8 Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS Date: SEP 101986 i
t l