GPU Nuclear Corporation Nuclear
=,o r s r 8o e
Middletown, Pennsylvania 17057 0191 717 944 7621 TELEX 84 2386 Writer's Direct Dial Number:
(717) 948-8461 4410-87-L-0068 Document ID Ol83P May 21,1987 US Nuclear Regulatory Commission Attn: Document Control Desk Washington, DC 20555
Dear Sirs:
Three Mile Island Nuclear Station, Unit 2 (TMI-2)
Operating License No. DPR-73 Docket No. 50-320 Reactor Pressure Vessel Integrity CPU Nuclear letter 4410-87-L-0013, dated January 19, 1987, advised that Babcock and Wilcox (B&W), the THI-2 reactor designer, had been requested to conduct a review of the dose rate profiles obtained from the cavity underneath the Reactor Vessel (RV).
Those dose rate profiles were reported in Reference 1.
B&W has concluded their review and provided the results of their analysis (Reference 2). A copy is attached for your information. The analysis concludes that the dose rate profiles measured in March 1986 with miniature ion chambers can be correlated to calculations which assumed cesium contamination sources without assuming there is fuel beneath the RV.
The contamination sources considered include the bathtub ring on the Reactor Building (RB) basement wall, RB wall contamination, RV insulation contamination, dissolved activity in basement water, and contamination on pipe surfaces.
Consistent, with the findings of the Burns and Roe (B&R) analysis, the B&W analysis concludes that the correlation of dose rate profiles and assumed contamination sources does not provide conclusive evidence as to the presence or absence of fuel below the RV.
In that regard, GPU Nuclear wishes to reiterate that the preponderance of the evidence provides no basis to doubt the integrity of the lower head.
Thus, CPU Nuclear plans to continue defueling activities.
jtod I
8706010124 870521 a subsidlary of the General Public Utilities Corporation PDR ADOCK 05000320 B I P
Document Control Desk May 21, 1987 4410-87-L-0068 As noted in our letter of January 19, 1987, GPU Nuclear plans to perform a gamma spectrometer survey of the cavity under the RV, as recommended by B&R, as part of the fuel accountability effort on a "non-interfering basis" with defueling. Those survey results will be provided to you as they become available.
Sincerely, M.,
~
F. R. Standerfer Director, TMI-2 FRS/JJB/eml Attachments cc: Regional Administrator, Region 1 - W. T. Russell Director, TMI-2 Cleanup Project Directorate - Dr. W. D. Travers President, Burns and Roe Company - W. R. Cobean i
g.:
Document Control Desk May 21, 1987 4410-87-L-0068 REFERENCES 1.
TMI-2 Technical Bulletin 86-25 dated May 2,1986, Revision 0, " Gamma Scaming of the Cavity Under the Reactor Vessel."
2.
" Babcock and Wilcox Analysis of Dose Rate Under TMI-2 Reactor Vessel,"
Prepared by N. L. Snidow and S. O. King, dated April 13, 1987, B&W Document No. 51-1167938-00.
ATTACHMENT 35 Pages 4410-87-L-0068 BWNP 2003216 (10/86 Ba en
(
np, DOCUMENT RELEASE NOTICE (DRN) k-Paga of CONTRACT NO PLANT CHARGE NO PELEASE 582-7371 T4I-2 SAFETY PART VARK/TGK.
B&W 00CUVENT NO 00CUVENT TITLE CCY C SS pgL GROUP SEQ (30 Chancters Yummi A 77, (0,
pCRi 3747 16 & 23 411 51-1167938-00 Dose Pate Under VII-2 Vessel N
S N
QE0uiRED DISTRIBUTION CDS GRN 00C INF00V ATiCN COP!ES CDS ORN OCC 04GANilAfl0N C9 TE rNoivt0u AL S N AYE PAPEA FICHE PAAEG FQE L. J. Stanek 1
1 1
D. A. Nitti l
1 1
S. Q. King 1
1 1
N. L. SnidCu 1
1 1
J. D. Carlton 1
1 1
S. D. Iayne 1
1 PROJECT ENGINEER /PV APPA0V AL (sign ATuaE)
(PCINTED NAVE)
GELEASE0 8Y tPREPARER) /
4/jy/g REviE AED By a
fy/Q 4 //>//p (SIGN ATURE)
A,fg
' 3/77 (S.GN Ait.a E >
/
mNTE0 NAVE, N.L. Snidow Donald A. Nitti
,pRiNTE0 NAVE 3