N 286B174650 PHILADELPHIA ELECTRIC COMPANY 23O1 MARKET STREET P.O. BOX 8699 PHILADELPHIA. PA.19101 JOHN S. KEMPER V IC E-P R E SI D E N T

- (N640sEE RlNG ASAD RESE ARCH November 19, 1986 Mr. Thomas E. Murley, Director United States Nuclear Regulatory Commission Of fice of Inspection & Enforcement, Region I 631 Park Avenue King of Prussia, PA 19406

Subject:

USNRC IE Region I Letter Dated October 22, 1986 RE:

Site Inspection of August 4 - September 28, 1986 Inspection Report No. 50-353/86-12 Limerick Generating Station, Unit 2 File: QUAL l-2-2 (353/86-12)

Dear Mr. Murley:

In response to the subject letter regarding the item identified during the subject inspection of construction activities authorized by NRC License No.

CPPR-107 we transmit herewith the following:

Attachment I - Response to Appendix A 4

Should you have any questions concerning these items, we would be pleased to discuss them with you.

Sincerely,

. f Mh J. S. Kemper LCD/pc Attachment Copy to: Director of Inspection and Enforcement United States Nuclear Regulatory Commission Washington, DC 20555 R. Gramm, assigned USNRC Resident Inspector 8612O20423 861119 P

{DR ADOCK 05000353

PDR k

s\\

fro \\

,s Attachment I 2868174650 Response to Appendix'A - Item B Violation

- 10 CFR 50, Appendix B, Criterion XIII, and the Limerick Preliminary Safety 1

Analysis Report Appendix D.4.9, require that equipment be stored in accordance -

with vendor instructions. Woodward Governor instruction EG-B10C specifies that the governor is to be filled with lubricating oil while in storage.

Contrary to the above, as of September 17, 1986, the Bechtel Maintenance Log did not specify the requirement to fill the diesel' generator governors and the governors were found empty of lubricating oil.

Response

The diesel generator governors were inspected by a representative of the Woodward Governor Company. No damage or unsatisfactory conditions were identified during the inspection. The governors have been filled with oil to the required level. The requirements for filling the governors with oil and for periodically verifying governor. oil level have been added to the. Bechtel Maintenance Log for the diesel generators.

To prevent recurrence of these conditions, a training session was held for the applicable Bechtel Long Term Maintenance Engineers. The training class included a review of the methods and sources of information to be used to determine maintenance / storage requirements for permanent plant equipment.

t l

l l

I 1/1 353 86-12

.