Requests Permission to Use Nalco 1360 & Nalco 1372 for Cooling Water Treatment at Discharge Point 001.Existing Treatment Program,Utilizing Nalco 1336,1370 & 2513,will Be Terminated Upon Approval.Bulletins & Data Sheets Encl
ML20214H251
Person / Time
Site: Limerick  
Issue date: 08/05/1986
From: Willsey W
PECO ENERGY CO., (FORMERLY PHILADELPHIA ELECTRIC
To: Hinkle R
PENNSYLVANIA, COMMONWEALTH OF
References
NUDOCS 8608130056
Download: ML20214H251 (17)


Text

_. _ _ _ _

.)

_[N PHILADELPHIA ELECTRIC COMPANY 2301 M ARKET STREET P.O. BOX 8699 PHILADELPHIA, PA.19101 (21518414000 August 5, 1986 Mr. Richard Hinkle Chief, Facilities Section Department of Environmental Resources 1875 New Hope Street Norristown, PA 19401 RE:

Limerick Generating Station NPDES Permit PA 0051926

Dear Mr. Hinkle:

In accordance with Section 92.7 " Reporting of New or Increased Discharges", of the Departments' Rules and Regulations, and pursuant to "Other Requirements" item E of the subject NPDES permit, we hereby request permission to use two chemical products for cooling water treatment at Limerick Generating Station, discharge point 001 (combined discharges).

The two chemical products are:

NALCO 1360 (polymaric zinc, 5% by weight zinc, 15%

by weight polyacrylate) and NALCO 1372 (tolyltriazole (TTA)/ phosphate, 4.2% by weight organic phosphate, 4.8% by weight in organic phosphate).

These NALCO products will be evaluated as a means to control scale and corrosion in the Unit #1 cooling water system.

Use of these chemical products is not expected to violate effluent limitations specified in the subject NPDES permit.

The TTA and polyacrylate contained in NALCO products 1372 and 1360 are the same chemicals previously approved for discharge at Limerick Generating Station (NALCO products 1336 and 1370 respectively.)

Nne

$QQ The NALCO 1360 (polymaric zinc) will be evaluated as a means mo to control steel corrosion.

We intend to maintain a 88 concentration up to 15 mg/l as product in the cooling water mo system.

We do not expect to exceed the Federal Effluent gg Guideline of 1 mg/l total zine in discharge 001.

88 n<

5 The NALCO 1372 (TTA/ phosphate) will be used and tested as a 8fj om means to control scale and reduce silt, iron and manganese

{#

$$a deposition in the cooling water system.

We intend to maintain a di concentration up to 15 ppm as product in the cooling water system.

i

.I

. The concentration of these chemicals products in the cooling tower blowdown discharge is expected to be the same as stated above.

As submitted in our NPDES permit application, the Unit #1 cooling tower blowdown rate is approximately 7.02 million gallons per day.

The existing treatment program which uses NALCO 1336, 1370 and 2513 will be terminated upon approval of this new treatment program.

Attached are product bulletins and Material Safety Data Sheets on the two NALCO products.

Confidential information, such as the chemical formula for these chemical products, has been sent to you directly from the NALCO Chemical Company.

If you have any questions or concerns, please call David W. Mobraaten at (215) 841-5679.

Sincerely yours, bbl W. B. Willsey Director Environmental Affairs Attachment DWM:nas cc:

J.

A.

Feola, DER w/ att.

NRC, Director, ONRR Washington, DC w/ att.

l NRC, Administrator, OIE King of Prussia, PA w/ att.

Utility Product Chemicals Bulletin 9

SUPER ZINC a

CORROSION 1360 1xn181 Ton Product Benefits e Extends the lifetime of system o Minimizes acid usage; pH above components 8.0 is optimum o Minimizes maintenance of I

corroded components Principal Uses SUPER ZINC 1360 is designed to utility recirculating cooling water minimize corrosion of mild steel systems.

and copper components in electric General Description SUPER ZINC 1360 is a liquid Form Clear, colorless liquid polymer zinc corrosion inhibitor.

Odor Slight sulfurous Specific Gravity 1.20 l

pH (Neat) 3.7 Freeze Point 22 F 1

Application SUPER ZINC 1360 should be fed of your system, the water chemistry, directly from the drum or bulk and the severity of problems storage tank to a location in the encountered. Your Nalco Utility l

system where it will be uniformly Account Manager will recommend mixed and thoroughly distributed. It the optimum dosage necessary to should be fed continuously to ensure maximum program per-maintain optimum product activity.

formance for your system.

The specific dosage of SUPER For specific feeding and material ZINC 1360 will vary depending compatibility instructions, consult upon the operating characteristics your Nalco Utility Account i

Manager.

Handling and Storage SUPER ZINC 1360 is an acidic 15 minutes; for eyes, also get medi-solution and should be handled cal attention. Do not take internally.

with caution to prevent contact with Keep out of reach of children.

j skin, eyes, or clothing. In case of RemW %ld h@

contact, immediately flush with limit is one year

  • large amounts of water for at least Shipping SUPER ZINC 1360 is available in The product is shipped from bulk or in 55 gallon, nonreturnable Chicago, Illinois.

lined steel drums. The not drum weight is approximately 550 pounds.

NALCO CHEMICAL COMPANY UTILITY CHEMIC ALS 1GOi WEST OtEHL nOAO O NAPCF4vtLLE. ILLINOIS G0500 Sunsicianits IN Anct NfiNA AUSTRIA. HRAllL CHilf COLOM614 FCUADOR FINLANO f

SRANCf. hot t AND. e*0NG KONG IT Alf JAPAN PHILIPPINES SAUDI ARABtA SPAfN.

I SWE0f N VFNfluf L A ANO WEST GERMANY e Af flLIAf t$ IN AUSTRALIA CANADA ME AlCO.51NGAPORE. SOUTH Af MICA f AfWAN.UNittDeuNGDOM ANDfHE UNIT [D$fAfES y

Re9ssie,ed t,aaemaas os N ico chem.ca compan, e1985 Natco Chemical Company

=asse Alt Rights Reserved Printcal en U S A 1185

~

MATERIAL SAFETY DATA SHEET PRODUCT SUPER-ZINC 1360 INHIBITOR N ALC O Emergency Telephone Number Medical (312) 9201510 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 1 PRODUCT IDENTIFICATION TRADE NAME: SUPER-ZINC 1360 INHIBITOR DESCRIPTION: An aqueous solution of zine chloride and an acrylic polymer NFPA 704M RATING 2 HEALTH 1 FLAMMABILITY 0 REACTIVITY 0 OTHER 0= Insignificant 1= Slight 2= Moderate 3=High 4= Ext,reme SECTION 2 HAZARDOUS INGREDIENTS Our hazard evaluation has identified the following chemical ingredient (s) as hazardous under OSHA's Hazard Communication Rule, 29 CFR 1910.1200. Consult Section 14 for the nature of the hazard (s).

INGREDIENT (S)

CAS #

APPROX.%

Zinc chloride 7646-85-7 10-20 4

SECTION 3 PRECAUTIONARY LABEL INFORMATION Warning: Causes eye injury and skin irritation. Do not get in eyes.

Avoid contact with skin and clothing. Wear goggles or face shield when handling. Avoid prolonged or repeated breathing of vapor. Use with adequate ventilation. Do not take internally.

Empty containers may contain residual product. Do not reuse container unless properly reconditioned.

SECTION 4 FIRST AID INFORMATION EYES:

Immediately flush for at least 15 minutes while holding eyelids open. Call a physician at once.

SKIN:

Iztmediately flush with water for at least 15 minutes.

j For a large splash, flood body under a shower. Call a physician at once.

INGESTION:

Do not induce vomiting. Give water. Call a physician.

NOTE TO PHYSICIAN: No specific antidote is known. Based on the individual reactions of the patient, the physician's judgment should be used to control symptoms and clinical condition.

CAUTION:

If unconscious, having trouble breathing or in convulsions, do not induce vomiting or give water.

NOTE TO PHYSICIAN: Probable mucosal damage may contraindicate the use PAGE 1 0F 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER e NAPERVILLE, ILLINOIS GQ5GG-1024 AncA a t a.001 -0500

MATERIAL SAFETY DATA SHEET PRODUCT SUPER-ZINC 1360 INHIBITGR N ALC O

(

Emergency Telephone Number Medical (312) 9201510 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 4 FIRST AID INFORMATION

( CONTINUED )

of gastric lavage. Measures against circulatory shock, respiratory depression and convulsions may be needed.

SECTION 5 HEALTH EFFECTS INFORMATION PRIMARY ROUTE (S) OF EXPOSURE:

Eye, Skin EYE CONTACT:

Can cause moderate irritation. Can causJ acidic, type burns.

SKIN CONTACT:

Can cause moderate irritation. Can cause acidic, type burns.

SYMPTOMS OF EXPOSURE: A review of available data does not identify any symptoms from exposure.

AGGRAVATION OF EXISTING CONDITIONS: A review of available data does not identify any worsening of existing conditions.

SECTION 6 TOXICOLOGY INFORMATION

(

ACUTE TOXICITY STUDIES: No toxicity studies have been conducted on this product.

SECTION 7 PHYSICAL AND CHEMICAL PROPERTIES l

COLOR: Clear colorless FORM Liquid ODOR: Slight DENSITY:

10 lbs/ gal.

SOLUBILITY IN WATER:

Completely SPECIFIC GRAVITY:

1.24 0 60 Degrees F ASTM D-1298 pH (NEAT) 3.5 ASTM E-70

=

FREEZE POINT:

22 Degrees F ASTM D-ll77 BOILING POINT:

Greater than 212 Degrees F 0 760 mm Hg ASTM D-86 FLASH POINT:

None (PMCC)

ASTM D-93 NOTE: These physical properties are typical values for this product.

SECTION 8 FIRE AND 'IXPLOSION INFORMATION FLASH POINT: None (PMCC.) ASTM D-93 EXTINGUISHING MEDIA: Not applicable UNUSUAL FIRE AND EXPLOSION HAZARD: Treat like an acid fire.

PAGE 2 OF 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER e NAPERVILLE. ILLINOIS GO5GG-1024 AF4E A 312 001 -0500

MATERIAL SAFETY DATA SHEET PRODUCT SUPER-ZINC 1360 INHIBITOR N ALC O

' mergency Telephone Number E

Medical (312) 920-151o (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 9 REACTIVITY INFORMATION INCOMPATIBILITY: Avoid alkaline materials (eg. ammonia and its solutions, carbonates, sodium hydroxide (caustic), potassium hydroxide, calcium hydroxide (lime), cyanides, sulfides, hypochlorites, chlorites) which can generate heat with splattering or boiling and the release of toxic fumes.

THERMAL DECOMPOSITION PRODUCTS:

In the event of combustion CO, CO,

2 NOx, sox, hcl cay be formed. Do not breathe smoke or fumes. Wear suitable protective equipment.

SECTION 10 PERSONAL PROTECTION EQUIPMENT RESPIRATORY PROTECTION: Respiratory protection is not normally needed since the volatility and toxicity are low.

If significant vapors, mists or aerosols are generated, wear a NIOSH approved or equivalent respirator, (ANSI Z 88.2, 1980 for requirements and selection).

For large spills, entry into large tanks, vessels or enclosed small j

spaces with inadequate ventilation, a pressure-demand, self-contained breathing apparatus is recommended.

VENTILATION: General ventilation is recommended.

PROTECTIVE EQUIPMENT: Wear gloves, boots, apron and a face shield with chemical splash goggles (ANSI Z 87.1 requirements and selection of gloves, goggles, shoes, etc.).

A full slicker suit is recommended if gross exposure is possible.

The availability of an eye wash fountain and safety shower is recommended.

If clothing is contaminated, remove clothing and thoroughly wash the affected area. Launder contaminated clothing before reuse. Discard contaminated shoes and leather items.

SECTION 11 SPILL AND DISPOSAL INFORMATION IN CASE OF TRANSPORTATION ACCIDENTS, CALL THE FOLLOWING 24-HOUR TELEPHONE NUMBER (312-920-1510)

SPILL CONTROL AND RECOVERt:

Small liquid spills: Contain with absorbent material, such as saw dust, clay, soil or any commercially available absorbent.

Shovel PAGE 3 0F 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER e NAPERVILLE. ILLINOIS GOSGG-1024 AnC A 312 901 0500

~

MATERIAL SAFETY DATA SHEET r

PRODUCT SUPER-ZINC 1360 INHIBITOP, N A LC O l

Emergency Telephone Number Medical (312) 920-151o (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 11 SPILL AND DISPOSAL INFORMATION

( CONTINUED )

reclaimed liquid and absorbent into recovery or salvage drums for disposal. Refer to CERCLA in Section 14.

Large liquid spills: Dike to prevent further movement and reclaim into recovery or salvage drums or tank truck for disposal. Refer to CERCLA in Section 14.

For large indoor spills, evacuate employees and ventilate area. Those responsible for control and recovery should wear the protective equipment specified in Section 10.

DISPOSAL:

If this product becomes a waste, it does not meet the criteria of a hazardous waste as defined under the Resource Conservation and Recovery Act (RCRA) 40 CFR 261, since it does not have the characteristics of Subpart C, (i.e. D001 through D017) nor is it listed under Subpart D.

As a non-hazardous liquid waste, it should be solidified before disposal to a sanitary landfill. Can be deep-well injected in l

accordance with local, state and federal regulations.

SECTION 12 ENVIRONMENTAL INFORMATION AQUATIC DATA:

96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> static acute LC., to Rainbow Trout = 61 ppm 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> static acute LC., to Rainbow Trout = 110 ppm 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> static acute LC,. to Rainbow Trout = 230 ppm 95% Confidence Limit of 96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> LC.. = 43 - 79 ppm COMMENTS: Above study conducted with well-water at pH 3-8.5 hardess (as CACO ) of 225-275 ppm and alkalinity (CACO ) of 325-375 ppm.

3 3

OTHER STUDIES: When conducted in reconstituted soft water pH 7-7.5, hardness (as Caco.) of 40-45 ppm and Caco, alkanlinity of 30-35 ppm the 96 hour0.00111 days <br />0.0267 hours <br />1.587302e-4 weeks <br />3.6528e-5 months <br /> LC.

for Rainbow trout was 5.2 ppm (3.9 - 7.0 95% L.C.)

24 and 48 hour5.555556e-4 days <br />0.0133 hours <br />7.936508e-5 weeks <br />1.8264e-5 months <br /> LC., were 32 and 25 ppm respectively.

If released into the environment, see CERCLA in Section 14.

SECTION 13 TRANSPORTATION INFORMATION l

DOT PROPER S!!IPPING NAME/IIAZARD CODE - HAZARDOUS SUBSTANCE, LIQUID, N.O.S.

ORM-E NA 9188 CONTAINS

- ZINC CHLORIDE PAGE 4 OF 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER e NAPE AVILLE, ILLINOIS 80500-1024 Af 4E A 312-001 0500

MATERIAL SAFETY DATA SHEET PRODUCT SUPER-ZINC 1360 INHIBITOR N ALC O Emergency Telephone Number Medical (312) 920-151o (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 14 REGULATORY INFORMATION The following regulations apply to this product.

FEDERAL REGULATIONS:

1 OSHA'S HAZARD COMMUNICATION RULE, 29 CFR 1910.1200:

Based on our hazard evaluation, Lhe following ingredient in this product is hazardous and the reason is shown below.

Zinc chloride - Severe irritant Zinc chloride fume = TWA 1 mg/m8, STEL 2 mg/m8 ACGIH TLV CERCLA /SUPERFUND, 40 CFR 117, 302:

This product contains zine chloride, a Reportable Quantity (RQ) substance and if 50,000 pounds of product are released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D. C.

(1-800-424-8802).

T0XIC SUBSTANCES CONTROL ACT (TSCA):

i The chemical ingredients in this product are on the 8(b) Inventory List (40 CFR 710).

RESOURCE CONSERVATION AND RECOVERY ACT (RCRA), 40 CFR 261 SUBPART C & D If this product becomes a waste, it does not meet the criteria of a hazardous waste.

FEDERAL WATER POLLUTION CONTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 (formerly Sec. 307), 40 CFR 116 (formerly Sec. 311):

This product contains the following ingredient (s) covered by the Clean Water Act Zine chloride - Sec.Aon 307, 311 CLEAN AIR ACT, 40 CFR 60, SECTION 111, 40 CFR 61, SECTION 1121 This product does not contain ingredients covered by the Clean Air Act.

STATE REGULATIONS:

MICHIGAN CRITICAL MATERIALSt This product contains the following substance identified on the Michigan Critical Materials Registert Zine chloride PAGE 5 OF 6 i

NALCO CHEMICAL COMf8ANY ONE NALCO CENTER e NAPERVILLE. ILLINOlG GOSGG-1024 AFIE A 31 D 001 0500

MATERIAL SAFETY DATA SHEE.T

~

PRODUCT SUPER-ZINC 1360 INHIBITOR N ALC O

(

Emergency Telephone Number Medical (312) 920-1510 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 14 REGULATORY INFORMATION

( CONTINUED )

STATE RIGHT TO KNOW LAWS:

Regulated in those states using the TLV for zinc chloride as a criteria for listing.

SECTION 15 ADDITIONAL INFORMATION None SECTION 16 USER'S RESPONSIBILITY This product material safety data sheet provides health and safety information. The product is to be used in applications consistent with our product literature.

Individuals handling this product should be informed of the recommended safety precautions and should have access j

to this information. For any other uses, exposures should be evaluated so that appropriate handling practices and training programs can be established to ensure safe workplace operations.

Please consult your local sales representative for any further information.

I SECTION 17 BIBLIOGRAPHY SEE NALCO'S MSDS SECTION DESCRIPTION PREPARED BY: John J. Kasper, MSc., Toxicologist DATE ISSUED:

11/19/85 I

l PAGE 6 OF 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER e NAPERVILLE. ILLINOlG GO5GG-1024 AllE A 310 001 0500

5 Utility Product Chemicals Bulletin i

SURE-COOL

  • COOLING l

g 1372 TREATMENT SYSTEM

~

muco l

Product Benefits e Helps maximize turbine condenser i

j efficiency l

e Helps extend condenser tube life e Can reduce maintenance costs i

Principal Uses SURE-COOL 1372 is designed to silica. In addition, it helps inhibit inhibit mineral scales such as calcium corrosion of mild steel, copper. and

)

carbonate, magnesium silicate, copper alloys.

j calcium sulfate, and amorphous a

l General Description SURE-COOL 1372 is a synergistic Form Liquid blend of organophosphonate,inor-ganic phosphates, and copper corro.

Color Yellow l

sion inhibitors that can elfectively Odor Sfignt control scale under severe operating Density 11.1 lb/ gal conditions such as high TDS waters.

pH (Neat) 12.8

)

Freeze Point 5F FreezesThaw l

Recovery Complete Flash Point (PMCC)

None l

l Application SURE-COOL 1372 should be fed Your Nalco Utility Account Manager directly from the drum or bulk storage can recommend the optimum dosage i

l tank to a location in the system where necessary to er sure maximum j

it will be uniformly mixed and thor-program performance for your i

oughly distributed. It should be fed system. For specific feeding and continuously to maintain optimum material compatibility instructions.

product activ:ty.

consult your Nalco Utility Account anager.

The specific dosage of SURE COOL 1372 will vary depending upon the SURE-COOL 1372 should not be operating characteristics of your used in the trea' ment of potable water, system, the water chemistry, and the or where contamination of potable severity of problems encountered.

water may occur.

(Continued on Reverso Side)

N A t. C O CHEMICAL COMPANY UTILITY CHEMICAL.B 1001 Wi H f OtE f 4L MO AO O NAPEl~avet.LC. ILLINOIS 0050G iA t fI t AN 1 40Nfl FI P f 7 JA AN 4P N1 AUDs & ARIA SPA SWfflfN vt Nflutl4 AND Wl5f Of flMANT e Af flUATES IN AU$fRAUA CANADA Mi mig;f) %sNf;A6 Mint south Af H8CA f AdW AN UNITEOasNGOOtA ANO THf uNittD$f Atts fbpsenhl bejeman of N4co Ctwwmt# Comgwny Ot965 N#co Cv=c# Compa*,

s At fkjhts Reserveret Peved a U S A to 85 me....

.N NALCO Handling and Storage SURE-COOL 1372 is a very alkaline for at least 15 minutes; for eyes, also solution and should be handled wih get medical attention. Do not take extreme caution. Do not get in eyes, internally. Keep out of reach of on skin, or on clothing. Goggles or children. '

face shield are recommended for Recommended in-plant storage limit handling. In case of contact, immedi-is one yeat ately flush with large amounts of water Shipping SURE-COOL 1372 is available in bulk mately 611 pounds net. The product is quantities or in 55-gallon nonreturn-shipped from the nearest manufactur-able steel drums weighing approxi-ing or warehousing facility.

I

MATERIAL SAFETY DATA SHEET SURE-COOL 1372 MULTIFUNCTIONA)

PRODUCT N ALC O

(

Emergency Telephone Number creTinu 1 nonnitrT inruTirtrammtnu TRADE NAME: SURE-COOL 1372 MULTIFUNCTIONAL DESCRIPTION: An aqueous solution of a phosphonate, phosphate and an aryltriazole salt NFPA 704M RATING 2 HEALTH 0 FLAMMABILITY 0 REACTIVITY 0 OTHER 0= Insignificant 1= Slight 2= Moderate 3=High 4= Extreme SECTION 2 HAZARDOUS INGREDIENTS ingredient (s) as hazardous under OSHA's Hazard Communication Rule, 29 CFR 1910.1200. Consult Section 14 for the nature of the hazard (s).

INGREDIENT (S)

CAS #

APPROX.%

Potassium hydroxide 1310-58-3 1-10 SECTION 3 PRECAUTIONARY LABEL INFORMATION Warning: Causes eye injury and skin irritation. Do not get in eyes.

Avoid contact with skin and clothing. Wear goggles or face shield when handling. Avoid prolonged or repeated breathing of vapor. Use with I

adequate ventilation. Do not take internally.

Empty containers may contain residual product. Do not reuse container unless properly reconditioned.

SECTION 4 FIRST AID INFORMATION l

EYES:

Immediately flush for at least 15 minutes while holding eyelids open.. Call a physician at once.

SKIN:

Immediately flush with water for at least 15 minutes.

For a large splash, flood body under a shower. Call a physician at once.

INGESTION:

Do not induce vomiting. Give water.

NOTE TO PHYSICIAN: No specific antidote is known. Based on the individual reactions of the patient, the physician's judgment should be used to control symptoms and clinical condition.

CAUTION: If unconscious, having trouble breathing cr in convulsions, do not induce vomiting or give water.

NOTE 'IO PHYSICIAN:

Probable mucosal damage may contraindicate the use of gastric lavage. Measures against circulatory shock, respiratory l

PAGE 1 OF 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER e NAPERVILLE, ILLINOIS G0588-1024 AMEA 319 001 9500 l

MATERIAL GAFETY DATA SHEET Sm-COOL 1372 Mm.TIMCTIONAI.

l PRODUCT N ALC O Emergency Telephone Number Medical (312) 920151o (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />)

SECTION 4 FIRST AID INFORMATION

( CONTINUED }

depression and convulsions may be needed.

SECTION 5 HEALTH EFFECTS INFORMATION PRIMARY ROUTE (S) OF EXPOSURE: Eye, Skin EYE CONTACT:

Can cause injury cr damage.

SKIN CONTACT Can cause caustic type burns.

SYMPTOMS OF EXPOSURE A review of available data does not identify any symptoms from exposure.

AGGRAVATION OF EXISTING CONDITIONS A review of available data does l

not identify any worsening of existing conditions.

SECTION 6 TOXICOLOGY INFORMATION ACUTE TOXICITY STUDIES: Acute toxicity studies hava act been conducted

(

en this product, but toxicity studies of the ingredient (s) in Section 2 have been reviewed. The results are shown below.

ACUTE ORAL TOXICITY (ALBINO RATS):

Potassium hydroxide LD., = 365 mg/kg PRIMARY SKIN IRRITATION TEST (ALBINO RA*3 BITS):

COMMENTS: Potassium hydroxide 24-hour contact with 50 mg produced severe irritation SECTION 7 PHYSICAL AND CHEMICAL PROPERTIES COLOR: Amber FORMS Liquid DENSITY:

12.2 lbs/ gal.

SOLUBILITY IN WATER:

Completely pH (NEAT) =

12.8 ASTM E-70 VISCOSITY:

11 cps 9 72 Degrees F ASTM D-2983 FREEZE POINT:

Less than 19 Degrees F ASTM D-1177 FLASH POINT:

None (PMCC)

ASTM D-93 NOTE: These physical properties are typical values for this product.

SECTION 8 FIRE AND EXPLOSION INFORMATION FLASH POINT None (PMCC) ASTM D-93 EXTINGUISHING MEDIA Based on the NFPA guide, use dry chemical, PAGE 2 OF 6 NALCO CHEMICAL COMPANY ONE NALCO CENTER

  • NAPERVILLE. ILLtNOIS GOSOG-102e*

Anc A 31 s2 001 0500

MATERIAL SAFETY DATA SHEET SURE-COOL 1372 MULTIFUNCTIONA; PRODUCT N ALC O

(

Emergency Telephone Number l

M artir af f 3191 Q9018iin f?d hnural alcohol foam, carbon dioxide or other extinguishing agent suitable for Class B fires. Use water to cool containers exposed to fire. For large fires, use water spray or fog, thoroughly drenching the burning material.

UNUSUAL FIRE AND EXPLOSION HAZARD: Not applicable SECTION 9 REACTIVITY INFORMATION INCOMPATIBILITY: Avoid contact with strong acids (eg. sulfuric, phosphoric, nitric, hydrochloric, chromic, sulfonic) which can generate j

heat, splattering or boiling and the release of toxic fumes.

1 THERMAL DECOMPOSITION PRODUCTS: In the event of combustion CO, CO, may be formed. Do not breathe smoke or fumes. Wear suitable protective equipment.

SECTION 10 PERSONAL PROTECTION EQUIPMENT RESPIRATORY PROTECTION: Respiratory prctection is not normally

[

needed.

If significant mists or aerosols are generated, wear a NIOSH approved or equivalent respirator, (ANSI Z 88.2, 1980 for requirements and selection).

~ For large spills, entry into large tanks, vessels or enclosed small spaces with inadequate ventilation, a pressure-demand, self-contained breathing apparatus is recomended.

VENTILATION: General ventilation is recommended.

PROTECTIVE EQUIPMENT Wear gloves, boots, apron and a face shield with chemical splash goggles (ANSI Z 87.1 requirements and selection of gloves, goggles, shoes, etc.).

A full slicker suit is recomended if gross exposure is possible.

The availability of an eye wash fountain ano safety shower is recommended.

If clothing is contaminated, remove clothing and thoroughly wash the affected aren.

Launder contaminated clothing betore reuse. Discard contaminated shoes and leathat items.

SECTION 11 SPILL AND DISPOSAL INFORMATION IN CASE OF TRANSPORTATION ACCIDENTS, CALL THE FOLLOWING 24-HOUR l

l PAGE 3 OF 6 NALCO CHEMICAL COMPANY ONG NALCO CENTER e NAPERVILLE. ILLINOlG 00S0G-1024 Af 4C A 31 H 001 0000

MATERIAL SAFETY DATA SHEET SURE-COOL 1372 MULTIFUNCTIONAL PRODUCT N A LC O Emergency Telephone Number Medical (312) 9201510 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) s r. u s s u n As araLa. anu u s arusnu a ne vrum a a vn s wn a a n u-- - r -

TELEPHONE NUMBER (312-920-1510)

SPILL CONTROL AND RECOVERY:

Small liquid spills: Contain with absorbent material, such as saw dust, clay, soil or any commercially available absorbent.

Shovel reclaimed liquid and absorbent into recovery or salvage drums for disposal. Refer to CERCLA in Section 14.

Large liquid spillst Dike to prevent furthe' movement and reclaim into recovery or salvage drums or tank truck for disposal. Refer to CERCLA I

in Section 14.

DISPOSAL:

If this product becomes a waste, it meets the criteria of a hazardous waste as defined under the Resources Conservation and Recovery Act (RCRA) 40 CFR 261. Hazardous Waste D002.

As a hazardous liquid waste, it must b3 solidified before disposal in a landfill (Hazardous Waste Treatment, Storage and Disposal facility).

l

(

Can be deep-well injected in accordance with local, state and federal regulations.

. SECTION 12 ENVIRONMENTAL INFORMATION If released into the environment, see CERCLA in Section 14.

SECTION 13 TRANSPORTA't!ON INFORNATION i

DOT PROPER SHIPPING NAME/ HAZARD CODE - ORM-B, N.O.S. NA 1760 CONTAINS

- POTASSIUM HYDROXIDE SECTION 14 REGULATORY INFORMATION The following regulations apply to this product.

FEDERAL REGULATIONS:

OSHA'S HAZARD COMMUNICATION RULE, 29 CFR 1910.12003 1

l Based on our hazard evaluation, the following ingredient in this product is hazardous and the reason is shown below.

i Potassium hydroxide - Severe irritant Potassium hydroxide = TWA 2 mg/m8 (ceiling) ACGIH TLV i

I PAGE 4 OF 6 l

NALCO CHEMICAL COMPANY ONE NALCO CENTUM e NAPEMVILLC. ILLINOlG 00000 102<1 l

Ant A 3157 001.u000 l

MATERIAL SAFETY DATA SHEET SURE-COOL 1372 MULTIFUNCTIONAL PRODUCT l

N ALC O f

Emergency Telephone Number Medical (312) 9201510 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) anuaavn av nsuunnaunI a nr vnran I Iup

\\ Lun&&nunu / -'

CERCLA /SUPERFUND, 40 CFR 117, 302:

This product contains potassium hydroxide, a Reportable Quantity (RQ) substance and if 100,000 pounds of product are released, it requires notification to the NATIONAL RESPONSE CENTER, WASHINGTON, D. C.

(1-800-424-8802).

TOXIC SUBSTANCES CONTROL ACT (TSCA):

The chemical ingredients in this product are on the 8(b) Inventory List (40 CFR 710).

RESOURCE CONSERVATION AND RECOVERY ACT (RCRA), 40 CI'R 261 SUBPART C & D:

If this product becomes a waste, it does meet the criteria of a hazardous waste as defined under RCRA 40 CFR 261 (consult Section 11).

FEDERAL WATER POLLUTION COFTROL ACT, CLEAN WATER ACT, 40 CFR 401.15 (formerly Sec. 307), 40 CFR 116 (formerly Sec. 311):

This product contains the following ingredient (s) covered by the Clean Water Act:

Potassium hydroxide - Section 311

(

CLEAN AIR ACT, 40 CFR 60, SECTION 111, 40 CFR 61, SECTION 112

.- This product does not contain ingredients covered by the Clean Air Act.

STATE REGULATIONSt MICHIGAN CRITICAL MATERIALS j

This product does not contain ingredients listed on the Michigan i

l Critical Materials Register.

l l

STATE RIGHT TO KNOW LAWS:

j Regulated in those states using the TLV for potassium hydroxide as a j

criteria for listing.

SECTION 15 ADDITIONA!, INFORMATION l

i None l

SECTION 16 USER'S RESPONS!B!!.!TY I

l This product material safety data sheet provides health and safety l

information. The product is to be used in applications consistent with our product literature.

Individuals handling this product should be i

informed of the recommended safety precautions and should have access j

to this information. For any other uses, exposures should be evaluated PAGE 5 OF 6 NALCO CHUMICAL COM55ANY ONE NALCO CENicM e NAPEnVILLE, ILLINOlG 00500-1021 A84E A 31H Ou t 0500

MATERIAL SAFETY DATA SHEET PRODUCTSm<oot 1372 MutTIm,,crIoNAL N A LC O j

Emergency Telephone Number i

Medical (312) 9201510 (24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br />) l SECTION 16 USER'S RESPONSIBILITY

( CONTINUED )

~\\

so that appropriate handling practices and training programs can be established to ensure safe workplace operations.

Please consult your local sales representative for any further information.

1 SECTION 17 BIBLIOGRAPHY I

SEE NALCo'S MSDS SECTIoN DESCRIPTION i

l j

PREPARED BY: John J. Kasper, MSc., Toxicologist l

DATE ISSUED:

11/12/85 i

\\

l

(

4

)

)

l l

l l

I i

PAGE 6 oF 6 l

NALCO CHEMICAL COMPsANY ONE NALCO CENTEM e NAPEnVILLE, ILLINDIO 00500 1024 Afif' A 0110-001 18000