g TENNESSEE VALLEY AUTHORITY CH ATTANOOGA. TENNESSEE 374o1 SN 157B Lookout Place MAY 151987 TVA-SQN-TS-87-29 10 CFR 50.90 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C.
20555 Centlemen:
In the Matter of
)
Docket Nos. 50-327 Tennessee Valley Authority
)
50-328 SEQUOYAH NUCLEAR PLANT - TECHNICAL SPECIFICATION CHANGE 87-29 In accordance with 10 CFR 50.90, we are enclosing a requested amendment to licenses DPR-77 and DPR-79 to change the technical specifications of Sequoyah Nuclear Plant unite 1 and 2.
The proposed change revises table 3.8-2 to delete references to motor-operated valves (MOVs) with bypassed thermal overload (TOL) devices and MOVs which are no longer considered active because of 10 CFR 50 Appendix R configurations or because their movement is not required for safety.
In addition, the change also adds several active MOVs to the table which had been previously omitted. A typographical error in thq unit 1 table is also corrected.
The proposed technical specification change is identified in enclosure 1.
The justification for the proposed technical specification change is provided in enclosure 2.
A proposed determination of no significant hazards consideration performed pursuant to 10 CFR 50.92 is provided in enclosure 3.
Reference information on the Motor-Operated Valve Analysis and Test System (MOVATS) is provided in enclosure 4.
t 0
l C
4o\\ % 40 o
99 4
j9 8705270250 870515 PDR ADOCK 05000327 P
PDR An Equal Opportunity Employer
U.S. Nuclear Regulatory Commission MAY 151987
(
Enclosed is a check for the $150 amendment application fee required by 10 CFR.170.12.
Please direct questions you may have concerning this issue to Russell R. Thompson at (615) 870-7470.
Very truly yours, TENNESSEE LLEY AUTHORITY R. Gridley, rector Nuclear Safe y and Licensing Sworn to subscr,lAedbeforeme thi /3-ay of 7//d4P 1987 L L))VtbAA ' '
h ilfotary ' Pub'lic
/f My Commission; Expires [ Y,/ v}
Enclosures i
cc (Enclosures):
Mr. J. A. Zwolinski, Assistant Director for Projects Division of TVA Projects office of Special Projects U.S. Nuclear Regulatory Commission 4350 East West Highway EWW 322 Bethesda, Maryland 20814 4
Mr. Michael H. Mobley, Director (w/o Enclosures)
Division of Radiological Health T.E.R.R.A. Building 150 9th Avenue, N Nashville, TN 37203 Mr. G. G. Zech, Assistant Director Regional Inspections Division of TVA Projects Office of Special Projects l
U.S. Nuclear Regulatory Commission Region II 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Sequoyah Resident Inspector Sequoyah Nuclear Plant 2600 Igou Ferry Road Soddy Daisy, Tennessee 37379 i
e-.
n-,--
r. - - -,