,.,1 TO -3 9 9 DEC 2 21977 A

g o

i4EEDRANDUM FOR: Regis Boyle, PM Environmental Projects Branch 2, DSE FROM:

R. L. Gotchy Radiological Impact Section, RA3, DSE TliRU:

F. J. Congel, Leader flM Radiological Impact Section, RAD, DSE

SUBJECT:

INFOR"AL REVIEW 0F UPPSS-2 DRAFT PADIOLOGICAL MONITORING PR00PRf As requested in your mamo of Dece.mter 12, 1977, I have reviewed the fraft radiological raonitoring program for WNP-2.

A copy of the current RAB technical position is ancibsed for use by WPPSS in developing their final program. Also attached are my couments on the proposed WNP-2 program.

$/

R. L. Gotchy Radiological Inpact Section, R/G Division of Site Safety and Environmental Analysis

Enclosures:

as stated cc:

R. Hartfield (w/o encl.)

S. Hanauer H. Denton D. I'.uller L. Crocker DISTRIBUTION R. Vollmer Central File W. Kreger DSE Reading D. Crutchfield RAB Reading l

W. Regan R. Gotchy V. Moore F. Congel 773050280 RAB:DSEO/b RAB:DSE -k orr..

RLGotch):$$

FJCongel'.f

.u......

12/19/77 12/2,l./77 l

NRC FORM 318 (9 76) NRCM 0240 D u. s. aovsn= ment amenviwe orrscs. iero -ese sae 8605220561 771222 PDR ADOCK 05000397 A

PDR

Comments on Proposed WNP-2

-Radiological Environmental !1onitoring Program Table 6.1-1 (1)

Airborne Particulates & Radiofodine:

(a) locations should be relative to WNP-2 (not WNP-1 or 4).

(b) Although there are more sample locations than the minimal suggested, it is not clear that the " community having the highest calculated annual average ground-level D/Q" is to be sampled. The 4.2 mi. ESE location (Taylor Flat) may be appropriate for individuals but it is not clear that Ringold (4 mi. ENE) should not be sampled at all.

(c) It is not certain whether locations outside the exclusion zone but still on the Hanford Reservation are entirely appropriate for monitoring "offsite" populations--

this issue needs to be resolved.

(2)

Direct Radiation:

(a) Same comments as (a), (b) and (c) above.

(b) It is uncertain what "13 stations at 22-1/2 sectors" means--is this one more than the first 12, or in addition to?

Where are these locations?

(3)

Soil:

Not required by NRC.

(4)

River Water:

It should be clearly stated that monthly gamma isotopic analyses and cuarterly tritium analyses are to carried out.

(5)

Drinking Water:

(a) Same comments as in (4) above.

(b) NRC no longer requires gross 8 or strontium-90 analyses.

(6)

Ground Water:

Should clearly specify frequency of analyses.

(7)

Sediment:

f No longer required by NRC.

e e

2 (8) fliik:

(a) Same as (6).

(b) The locations for milk animals are puzzling; does this mean all farms between the SSE and the flE are sampled? What are the approximate distances from UtlP-2?

(9)-

Fish:

(a) Same as (b).

(b) Where are the control locations?

(10) lleat and Poultry:

No longer required by flRC.

(l'l ) Cooling Water:

What is _the significance of sampling cooling water from UNP-1 and 4 in th'e WNP-2 program?

(12) Footnote 11) to Table 6.1-1 should read " ground-level D/Q's".