Advises That Util Analysis of Shield Annulus Acceptable for Application to Shield Wall Base Design,Using RELAP-3 & 40% Design Margin.Flow Limiting Door Capability to Withstand Differential Pressure of 1,000 Psi Should Be Verified
ML20214G755
Person / Time
Site: Columbia 
Issue date: 08/08/1975
From: Tedesco R
Office of Nuclear Reactor Regulation
To: Deyoung R
Office of Nuclear Reactor Regulation
References
CON-WNP-0029, CON-WNP-29 NUDOCS 8605220479
Download: ML20214G755 (1)


Text

._

\\

r AUG 8 sg p

s.

R. C. DeYotang, Assistant Director for Light Water Reactors, Group 1. EL WFFSS 2-8ACRIFICIAL SHIELD ANNULUS PRESSURE RESFtEl5E FOR SEIELD RASE DESIGN (CONTINUATION OF TAR-908)

In response to your technical assistance request of July 16,1975, the Contaismaat systems Branch has reviewed the applicant's submittal of June 26, 1975. Per our request (memo R. Tedesco to R. DeYoung, May 2, 1975), the applicant has provided a revised pressure response analysis for the sacrificial shield annulus using the RELAP-3 camputer coda. This analysis is applicable only to the shield wall base design. We understand that further calculations will be submitted on about August 15, 1975 covering the shield wall design above the habe.

CSB Evaluation Using the applicant's input for a 60-node model of the annulus, we performed i

similar pressure response analyses using the RELAP-3 computer program. Our j

results confirm the pressures calculated by the applicant. For design basis purposes the applicant has increased the values of peak calculated differential l

pressure by a factor of 1.4 to account for uncertainties in the fluid dynamic phencuena. This is in accordance with our recommendation.

Conclusions t

i 1.

Based on the applicant's use of the RELAP-3 computer code, the application of a 40% design margin, and the results of our confirmatory calculations we conclude that the applicant's analysis of the shield annulus is acceptable for application to the shield wall base design.

2.

As noted in our mano of May 2,1975 (R. Tedesco to R. DeYoung), SEB should verify the capability of the flow limiting doors which encompass the recircult. tion lines, to withstand a differential pressure of 1000 psi.

habert L. Tedesco, Assistant Director i

l for Containmaant Safety Division of Technical Review l

ec: S. Hanauer I. Villaiva R. Heineman G. Lainas J. Glynn NRR Reading F. Schroeder J. Eudrick A. Giambusso CS Reading D. Eisenhut J. Shapaker W. Mcdonald CSB Reading O. Parr R. Cudlin E. Jacobs Central Files Nbp CSB.

TR:CSB

. CS..

o ' ""

  • CSB bett 7JKudrick

.GCLainas RLMdesco 8/6/75 8/(/75 8/6 /75

_ 8/[75 j

forse ALC 318 (Rev. 9-13) AFCM 0240 W u. s. eovan= ass =v em=viese orricas s re.ess.t.e 8605220479 75000E i

PDR ADOCK 05000397 A