__
~~-,,
,,a,
Russellville, Arkansas I
Sample Pathway or Nedium:
Surface Water, split Location:
ANO Discharge mDistance and Direction:
0.65-miles, 257' degrees Frequency:
Monthly Type.cf Analysis:
Gamma Isotopic Results (pC1/1)
Sample Date State Licensee Jan Below LLD Below LLD Feb Cs-137:
.4.5 +/- 2.9 Below'LLD Nar Below LLD Below LLD Apr Below LLD Below.LLD Nag Below LLD.
Xe-133: 73.53'+/- 4.92 Cs-137:
8.33 +/ :1.62 Jun-
'Eclaw LLD Xe-133:
83.31 +/- 7.56 Jul Below~LLD Below LLD Aug
'Cs-137:
1.3 +/- 0.8 Xe-133:
322 +/
-B.74 Sep Below LLD Below LLD-Oct Below LLD Below LLD Nov Below'LLD Below'LLD Dec Below LLD.
Below LLD Type of Analysis:
Tritium Frequency:
Quarterly Composite Results (pCi/1)
Ouarter State Licensee Jan - Mar 1730 +/- 260
- Not available Apr - Jun 2140 +/- 260
- Not available Jul - Sep 900 +/- 250
- Not available Oct - Dec 264 +/- 241
- Not available Lab results are not available 8705220213 870508 PDR ADOCK 05000313 R
PDR f
- Sample reports are not available at this time.
Page 1
' l9..j.
t-m 4
U
- s. y i h '.
1
.ARXANSAS-NUCLEAR ONE i
e'
<E
~
'Russellville, _ Arkansas.
Sample' Path ~ag or. Medium:
Airborne-Partic'ulate, w
Duplicate Location:
Danville (control)
L
- -Distanceland Direction
21, miles, 205. degrees
. Frequency:
Composite-E EType of~ Analysis:
Gamma Isotopic Monthly. Composite
' Licensee Date-Results (pC1/m3)
^
Jan Below LLD
.Feb,
Apr Not'available May~
Cs-139:
8.975 +/- 1.98 E-3 Cs-137:
11.59 +/- 1.56 E-3 Ru-103:-
23.20 +/- 3.29 E-3 Jun Not avai-lable Jul.
Not available u
Aug.
.Not available Sep
'Not.available
.0ct Not available:
~Nov Not available.
Dec Not available Quarterly Composite Licensee
'Date Results (pC1/m3)'
Jan Below LL'D r
2nd'Ouarter Cs-139:
1.913 +/- 0.272 E-3 l
- P Cs-137:
3,365 +/- 0.392 E-3 Ru-103:
3.897 +/- 0.381 E-3 3rd Quarter Below LLD 9th Quarter Below LLD
. Licensee'normally analyzes air f'lters' monthly.
However, since the Chernobyl accident, they bege1 analyzing samples quarterly
.Caccording to their technical specifications) due to the overload of. analyses.
Therefore, monthly samples were not analyzed.
January - December 1986 r
Page 7
^'
r u[. *..;f.
ARKANSAS NOCLEAR ONE Pussellv111e,' Arkansas
~
Sample Pathway or Medium:
Airborne-Charcoal' Cartridge Duplicate sample Location:
ANO Weather Station Distance and Direction:
0.55Emiles, 90 degrees Frequency:
Weekly Type;of Analysis:
Radioicdine.
State
-Licensee-Data Results Date
-Results (pC1/m3)-
CpCi/m3)
Jan:3 Except as indicated, Jan 2 Except as indicated, 7
.all-sampics below 8
all. samples are
-15 LLD 15 below LLD 24 22 29 29 Feb 7 Feb 5 12 12 19 19 5
26 Mar' 9 Mar 6 12 12 19 19 26 26
~Apr 2 No sample (1)
Apr 3 9
' S 16 16 22 23 30 30 May B May 6 14' No sample (2)-
14~
-I-131: 31.3 +/- 9.27 E-3 21 60.0 +/- 13 E-3 21 I-131: 35.1 +/- 3.95 E-3 28
~28 I-131: 50.1 +/- 9.07 E-3 Jun 5 Jun 4 12 12 17 17
. _ 25 25 Jul 3 Jul 1 8'
S 16 16 29 23 30 30
- Not 6V6116'010 (1) Sampic missed due to exercise (2) Sampler inoperative
- Lab results are not available Note Licensee analyzes samples as a composite from 7 locations.
January - December 1986 Page 10
f'
-4
~ ARKANSAS NUCLEAR ONE
'Russellville,_ Arkansas n.
s
. Sample Fathway or-Medium:
Direct Radiation i'
Environmental TLDs Frequency:
Quarterly-
'~ Type of Analysis:
Integrated Exposure Sample-Date:
Quarter 4 j_
State Licenses NRC Site Results Site
-Results' Site Results CmR)
CmR)
.CmR) p B3, 15.14 13 11 6 '
5-15.8, I
A1 1.4.73 3
14 1
15.2 All 16.12 2
17 21-117.5
. B15b 16.42
-16 16 29 17.3 l-E16 14.66 20 12 32 15.1 D3 15.35 23 15.
6 15.6 A9 15.19 4
15 17 16.1 A5 15.54 1
17 5
16.5 LFN 15,33 27 17 43 17.4 HG 15.70 39 16.2
-F10 13.37-38 13 20 13.7 j
18 15.52 37 missing 40 17.2 E7 14.73 42' 18 14 13.3
> ~
C6 14.38 11